1/32 DIN Digital Panel Meter

 K3GN

F-15

D

igi

ta

l pa

n

e

in

di

c

a

tors

Application Examples

Detection of Dust Exhaust

The change in the density of the dust is detected via the E3SA and 
discriminated by the K3GN.

Monitoring of Tank Pressure

The output of the pressure sensor is processed and the pressure is 
displayed. Remote monitoring of the operation is possible with the 
communications function.

Monitoring of Motor Load Current

If the startup time compensation of the K3GN is enabled, the K3GN 
will not be influenced by the inrush current from starting the motor, 
and no signal will be output from the K3GN.

Monitoring Difference between Two 
Line Speeds

The difference between the two line speeds is calculated by the PLC 
and the result is written via RS-485 to the K3GN where it is 
displayed.

Monitoring the Remaining Quantity of 
Soup

The distance to the surface of the soup is detected with an ultrasonic 
sensor and, based on this distance, the K3GN displays the remaining 
quantity. When the remaining quantity of soup decreases to less than 
20%, the K3GN lights the “Replenish” indicator.

Monitoring Number of Motor 
Revolutions

Exhaust

Grinder

Dust collecting machine

E3SA

4 to 20 mA

K3GN

OUT2 

(Upper upper-

limit alarm) 

Device stops

OUT1 
(Upper-limit 
alarm) Output 
reduction 
instruction

Foam

Beer

Tank

Exhaust valve

Pump

K3GN

Host PC

RS-485

RS-232C

E8AA 
Pressure 
Sensor

Power supply

Signal input

K3GN

24-VDC power supply

Electromag-
netic relay

K3FK  
CT Converter

OUT1 
(Upper-limit 
alarm)

OUT2 
(Lower-limit 
alarm)

RS-485 communications output 
(calculation result)

K3GN 
(Set the in-
put type to 
"Remote").

100 %

20 %

4 to 20 mA

K3GN

Volume of soup

OUT 1

Replenish

Ultrasonic Sensor

Large 

cup

Medium 

cup

Small 

cup

Power supply

Signal input

24-VDC power supply

Electromagnetic relay

0 to 1 A

4 to 20 mA

K3FK CT Converter

K3GN-NDC

K3GN-NDC

OUT1 (Upper limit)

OUT1 (Upper limit)

OUT2 (Lower limit)

OUT2 (Lower limit)

E2E Proximity 
Sensor

Summary of Contents for K3GN

Page 1: ...rrent PNP 2 Output Type C 2 relay contact outputs SPST NO C FLK 2 relay contact outputs SPST NO and RS 485 C L1 2 relay contact outputs SPST NO and DC current 0 to 20 mA 4 to 20 mA C L2 2 relay contac...

Page 2: ...VDC RS 485 K3GN PDC FLK 24 VDC 3 transistor outputs PNP open collector None K3GN PDT2 24 VDC RS 485 K3GN PDT2 FLK 24 VDC Item K3GN ND With DC voltage DC current and NPN input K3GN PD With DC voltage D...

Page 3: ...sistor outputs 150 m s2 three times each in 3 axes 6 directions Models with contact outputs 100 m s2 three times each in 3 axes 6 directions Weight Approx 100 g Main Unit only Degree of protection Fro...

Page 4: ...23 C 100 000 operations min at the rated load with a switching frequency of 1 800 operations hr Rated load voltage 24 VDC Max load current 50 mA Leakage current 100 A max Item RS 485 Communications me...

Page 5: ...mmunications writing is enabled and is out when it is disabled 3 Level indicator Displays the current level that the K3GN is in See below for details 4 Level Key Used to change the level 5 Mode Key Us...

Page 6: ...nergized Relays K3GN NDC 400 24 VDC K3GN NDC FLK 400 24 VDC K3GN NDC L1 400 24 VDC K3GN NDC L2 400 24 VDC Relation between Output Type and Relay Output Operation Hysteresis Set value Measurement value...

Page 7: ...5 VDC 1 to 5 VDC 0 to 10 VDC I K L Outputs Outputs relay or transistor outputs There is also a PASS output for models with transistor outputs I J K L B A 7 8 7 8 C 1 2 3 1 2 3 A 9 10 11 12 9 10 11 12...

Page 8: ...EEPROM Analog input terminal Pulse Control input terminal Control input circuit A D conversion circuit Waveform rectification circuit Micro computer Note 1 Transistor output models only 2 Linear outpu...

Page 9: ...r example when adjusting reference values Note This function can be used only when forced zero operation protection is released Changing the Display Color The color of the value displayed can be set t...

Page 10: ...erproof when gang mounted 7 mm 3 6 mm Main Display Character Size The K3GN uses M3 terminals A terminal cover is provided Panel Cutout Dimensions K3GN For installation insert the K3GN panel into the r...

Page 11: ...e surface of the soup is detected with an ultrasonic sensor and based on this distance the K3GN displays the remaining quantity When the remaining quantity of soup decreases to less than 20 the K3GN l...

Page 12: ...of the product may be damaged by organic solvents thinner benzine etc strong alkaline materials and strong acid materials 6 Avoid storing in high humidity or in a corrosive gas environment including d...

Page 13: ...hen setting up the control system 10 Install an external switch or circuit breaker and label them clearly so that the operator can quickly turn OFF the power 11 Ensure that the rated voltage is achiev...

Page 14: ...PAIR Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards codes or regulations that apply to the combination of products in the customer s ap...