45
6. Protective Functions
• Turn ON the power, activate the servo ON (S-ON) input signal, and
check that the color of the REF indicator changes from orange to
green. The machine may momentarily make a sound after the
servo is turned ON. This is due to the setting of the automatic filter
in the servo and is not an error.
• Check that all the protective functions, such as the emergency stop
and holding brake functions are working correctly.
7. PULSE Reference Input 2
• Input the reference pulse from the controller, and then check that
the machine is running in the correct direction and at the correct
rate designed by the settings. The machine may momentarily
make a sound after the machine moves. This is due to the setting
of the automatic filter in the servo and is not an error.
8. Filter Settings
• If the machine vibrates or if the positioning completed signal
(/COIN) repeatedly turns ON and OFF after the servomotor stops,
turn the FIL rotary switch from 0 to 1, and then to 0 again. If the
machine still vibrates, gradually increase the setting on the FIL
rotary switch from 0 to 7 until the optimum setting is reached.
Note: Use the screwdriver to change the set-
ting on the rotary switch. Never use
the screwdriver for any purpose other
than setting the rotary switch.
Step
Details
EMERGEN
CY
Reference Pulse
Controller
Select the FIL
setting with the
rotary switch.
Screwdriver
TOEP_C710806_01A_0_0.book Seite 45 Montag, 2. Juli 2007 4:24 16