2.3 Details of Services
H8GN
2-13
This service carries out reset, communications writing, multiĆSP, move to
protect level, move to setup area 1 and software reset.
MRC SRC
3 0 0 5
2
2
MRC SRC
Response
code
3 0 0 5
2
2
4
InstrucĆ
tion code
Related
informaĆ
tion
2
2
Service request PDU
Service response PDU
(1) Instruction code and related information
Instruction
code
Description
Related information
00
Communications writing
00: OFF (disabled)
01: ON (enabled)
01
Reset
00: Reset PV
01: Reset totalizing count value
02: Reset PV/totalizing count value
02
SVĆbank
00: Set value 0
01: Set value 1
02: Set value 2
03: Set value 3
06
Software reset *
00
07
Move to setup area 1
00
08
Move to protect level
00
* No response will be returned when a software reset is carried out.
(2) Response code
At normal completion
Response code
Name
Description
0000
Normal completion
No errors were found.
At occurrence of error
Response code
Error name
Cause
1001
Command too long
The command is too long.
1002
Command too short
The command is too short.
1100
Parameter error
Instruction code and related informaĆ
tion are wrong.
2203
Operation error
•
The
communications
writing"
parameter is set to OFF" (disĆ
abled). However, note that theerror
is accepted regardless of the comĆ
munications writing" parameter setĆ
ting (ON/OFF).
•
The command cannot be proĆ
cessed. For details, see (3)
Description of operating instrucĆ
tions and precautions" below.
•
CPU or EEPROM error
JOperation
instructions