![background image](http://html1.mh-extra.com/html/omron/h8gn/h8gn_owners-manual_742014013.webp)
CHAPTER 1 ABOUT COMMUNICATIONS METHODS
H8GN
1-4
The H8GNs communications specifications are set in the communications
setting level. These parameters are set on the H8GNs front panel.
The following table shows the communications parameters and their setĆ
ting ranges.
Parameter
Displayed
Characters
Setting Range
Set Value
Communications unit No.
0 to 99
0,
1
to 99
Baud rate
1.2 / 2.4 / 4.8 / 9.6 (k bit/s)
1.2 / 2.4 / 4.8 /
9.6
(k bit/s)
Communications data length
7 / 8 (bit)
7
/ 8 (bit)
Communications stop bit
1 / 2
1 /
2
Communications parity
None / even / odd
/
/
Highlighted characters indicate defaults.
Before you carry out communications with the H8GN, set up communicaĆ
tions unit No., Communication rate and other parameters by carrying out
the following procedure.
(1) Hold down the
key for at least three seconds to move from the
operation level" to the initial setting level."
(2) Press the
key for less than one second to move from the initial
setting level" to the communications setting level."
(3) Select the parameters as shown below by pressing the
key.
(4) Use the
or
keys to change the parameter set values.
H8GN
Communications unit No.
Baud rate
Communications data length
Communications stop bit
Communications parity
JCommunications
parameters
F Communications