background image

Warranty and Application Considerations

Read and Understand This Catalog

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have 
any questions or comments.

Warranty and Limitations of Liability

WARRANTY

OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or 
other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, 
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER 
ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET 
THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR 
IMPLIED.

LIMITATIONS OF LIABILITY

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, 
OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON 
CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE 
PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, 
INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE 
MODIFICATION OR REPAIR.

Application Considerations

SUITABILITY FOR USE

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of 
products in the customer's application or use of the products.
Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will 
be used.
Know and observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT 
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON 
PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR 
SYSTEM.

Disclaimers

PERFORMANCE DATA

Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a 
warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application 
requirements. Actual performance is subject to the OMRON 

Warranty and Limitations of Liability

.

CHANGE IN SPECIFICATIONS

Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with 
your OMRON representative at any time to confirm actual specifications of purchased product.

DIMENSIONS AND WEIGHTS

Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

Summary of Contents for H7CZ Series

Page 1: ...could be damaged if wired incorrectly The H7CZ removes these worries Set Value Limit You can set an upper limit for the set value to prevent unexpected operation of output devices caused by setting mi...

Page 2: ...er 8 pin socket 1 stage 6 digits Contact output SPDT 100 to 240 VAC H7CZ L8 12 to 24 VDC 24 VAC H7CZ L8D1 Model Page Y92A 48F1 9 Model Page Y92A 48 9 Model Page Y92F 30 9 Model Page Y92S 29 9 Model Ty...

Page 3: ...Output mode N F C R K 1 P Q and A One shot output time 0 01 to 99 99 s Reset system External minimum reset signal width 1 ms or 20 ms selectable Manual and Automatic reset internal according to C R P...

Page 4: ...24 VDC Noise immunity 1 5 kV between power terminals 600 V between input terminals Square wave noise by noise simulator pulse width 100 ns 1 s 1 ns rise Static immunity Malfunction 8 kV Destruction 1...

Page 5: ...cuit IN 14V 1 k Open Collector Voltage Output Contact Input DC Two wire Sensor Note Operates with transistor ON PLC or sensor 1 3 4 0 V for inputs Reset input Count input Note Operates with transistor...

Page 6: ...1 The mounting panel thickness should be 1 to 5 mm 2 To allow easier operation it is recommended that Adapters be mounted so that the gap between sides with hooks is at least 15 mm i e with the panel...

Page 7: ...ent the condition of resin products may deteriorate and may shrink or become harder Therefore it is recommended that resin products are replaced regularly The H7CZ s panel surface is water resistive c...

Page 8: ...t and internal connections Mounting hole dimensions P2CF 08 Top View Note The Socket can also be mounted to DIN track P2CF 08 E Finger Safe Terminal Model Dimensions Terminal arrangement and internal...

Page 9: ...5 10 25 25 1 000 500 The values shown in parentheses are for the PFP 50N Mounting Track PFP 100N PFP 50N 15 25 25 1 000 4 5 25 25 15 10 1 24 27 35 0 3 16 1 5 29 2 10 Mounting Track PFP 100N2 4 8 1 3...

Page 10: ...the individual U Key Set the counting speed using the U Key Set the Reset input signal width using the U Key Set the decimal point position using the U Key One digit after decimal point Two digits aft...

Page 11: ...ual U Key Note The monitor value is only displayed It cannot be set Key protect level KYPT From previous page To previous page Output ON count alarm set value monitor value Set each digit using the in...

Page 12: ...ting a prescale value Set the set value to a value less than Maximum countable value Prescale value Example If the prescale value is 1 25 and the counting range is 0 000 to 999 999 set the set value t...

Page 13: ...n the present value reaches the set value a signal is output according to the specified output mode UP Increment Mode DOWN Decrement Mode Counting starts when the count input is turned ON after turnin...

Page 14: ...et start status The present value display does not show the present value upon count up The outputs repeat one shot operation R The present value display returns to the reset start status after the on...

Page 15: ...s 0 to 999 999 Self holding output One shot The one shot output time can be set in the range 0 01 to 99 99s Input mode Operation after count completion UP DOWN Output mode setting P The present value...

Page 16: ...d if the alarm value setting for either of the two outputs is exceeded if a model with two outputs is used The total ON count will not be cleared by using the Reset Key Level Description Details Chang...

Page 17: ...of the rated ranges for vibration shock water exposure and oil exposure Do not use this Counter in dusty environments in locations where corrosive gasses are present or in locations subject to direct...

Page 18: ...l components e g electrolytic capacitors EEPROM is used as backup memory when the power is interrupted The write life of the EEPROM is 100 000 writes The EEPROM is written at the following times When...

Page 19: ...OR INAPPROPRIATE MODIFICATION OR REPAIR Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards codes or regulations that apply to the combinati...

Page 20: ...U S A Tel 1 847 843 7900 Fax 1 847 843 7787 Regional Headquarters OMRON EUROPE B V Wegalaan 67 69 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 Contact www ia omron com Tokyo...

Reviews: