H7CZ

18

• An inrush current of approx. 10 A will flow for a short time when the 

power supply is turned ON. If the capacity of the power supply is 
not sufficient, the Counter may not start. Be sure to use a power 
supply with sufficient capacity.

• Maintain voltage fluctuations in the power supply within the 

specified operating voltage range.

• When turning the power ON and OFF, input signal reception is 

possible, unstable, or impossible as shown in the diagram below.

• Inrush current generated by turning ON or OFF the power supply 

may deteriorate contacts on the power supply circuit. Turn ON or 
OFF to a device with the rated current of more than 10 A.

• If the prescale value setting is incorrect, a counting error will occur. 

Check that the settings are correct before using this function.

• Make sure that all settings are appropriate for the application. 

Unexpected operation resulting in property damage or accidents 
may occur if the settings are not appropriate.

• Do not leave the Counter for long periods at a high temperature 

with output current in the ON state. Doing so may result in the 
premature deterioration of internal components (e.g., electrolytic 
capacitors).

• EEPROM is used as backup memory when the power is 

interrupted. The write life of the EEPROM is 100,000 writes. The 
EEPROM is written at the following times:

• When the power supply is turned OFF
• When switching from Configuration Selection Mode or Function 

Setting Mode to Run Mode

• Dispose of the product according to local ordinances as they apply.

• When conforming to EMC standards, refer to the information 

provided in this datasheet for cable selection and other conditions.

• This is a class A product. In residential areas it may cause radio 

interference, in which case the user may be required to take 
adequate measures to reduce interference.

• Basic insulation is provided between power supply and input 

terminals, between power supply and output terminals, and 
between input and output terminals.  

• When double insulation or reinforced insulation is required, apply 

double insulation or reinforced insulation as defined in IEC 60664 
that is suitable for the maximum operating voltage with clearances 
or solid insulation.

• Connect the input and output terminals to devices that do not have 

any exposed charged parts.

Precautions for Correct Use 

Inp

u

t

Impossi

b

le

200 ms

5 ms

0 to 90 ms

0 to 1 s

Possi

b

le

Unsta

b

le

Unsta

b

le Impossi

b

le

Po

w

er 

s

u

pply

O

N

OFF

Conformance to EN/IEC Standards

Summary of Contents for H7CZ Series

Page 1: ...could be damaged if wired incorrectly The H7CZ removes these worries Set Value Limit You can set an upper limit for the set value to prevent unexpected operation of output devices caused by setting mi...

Page 2: ...er 8 pin socket 1 stage 6 digits Contact output SPDT 100 to 240 VAC H7CZ L8 12 to 24 VDC 24 VAC H7CZ L8D1 Model Page Y92A 48F1 9 Model Page Y92A 48 9 Model Page Y92F 30 9 Model Page Y92S 29 9 Model Ty...

Page 3: ...Output mode N F C R K 1 P Q and A One shot output time 0 01 to 99 99 s Reset system External minimum reset signal width 1 ms or 20 ms selectable Manual and Automatic reset internal according to C R P...

Page 4: ...24 VDC Noise immunity 1 5 kV between power terminals 600 V between input terminals Square wave noise by noise simulator pulse width 100 ns 1 s 1 ns rise Static immunity Malfunction 8 kV Destruction 1...

Page 5: ...cuit IN 14V 1 k Open Collector Voltage Output Contact Input DC Two wire Sensor Note Operates with transistor ON PLC or sensor 1 3 4 0 V for inputs Reset input Count input Note Operates with transistor...

Page 6: ...1 The mounting panel thickness should be 1 to 5 mm 2 To allow easier operation it is recommended that Adapters be mounted so that the gap between sides with hooks is at least 15 mm i e with the panel...

Page 7: ...ent the condition of resin products may deteriorate and may shrink or become harder Therefore it is recommended that resin products are replaced regularly The H7CZ s panel surface is water resistive c...

Page 8: ...t and internal connections Mounting hole dimensions P2CF 08 Top View Note The Socket can also be mounted to DIN track P2CF 08 E Finger Safe Terminal Model Dimensions Terminal arrangement and internal...

Page 9: ...5 10 25 25 1 000 500 The values shown in parentheses are for the PFP 50N Mounting Track PFP 100N PFP 50N 15 25 25 1 000 4 5 25 25 15 10 1 24 27 35 0 3 16 1 5 29 2 10 Mounting Track PFP 100N2 4 8 1 3...

Page 10: ...the individual U Key Set the counting speed using the U Key Set the Reset input signal width using the U Key Set the decimal point position using the U Key One digit after decimal point Two digits aft...

Page 11: ...ual U Key Note The monitor value is only displayed It cannot be set Key protect level KYPT From previous page To previous page Output ON count alarm set value monitor value Set each digit using the in...

Page 12: ...ting a prescale value Set the set value to a value less than Maximum countable value Prescale value Example If the prescale value is 1 25 and the counting range is 0 000 to 999 999 set the set value t...

Page 13: ...n the present value reaches the set value a signal is output according to the specified output mode UP Increment Mode DOWN Decrement Mode Counting starts when the count input is turned ON after turnin...

Page 14: ...et start status The present value display does not show the present value upon count up The outputs repeat one shot operation R The present value display returns to the reset start status after the on...

Page 15: ...s 0 to 999 999 Self holding output One shot The one shot output time can be set in the range 0 01 to 99 99s Input mode Operation after count completion UP DOWN Output mode setting P The present value...

Page 16: ...d if the alarm value setting for either of the two outputs is exceeded if a model with two outputs is used The total ON count will not be cleared by using the Reset Key Level Description Details Chang...

Page 17: ...of the rated ranges for vibration shock water exposure and oil exposure Do not use this Counter in dusty environments in locations where corrosive gasses are present or in locations subject to direct...

Page 18: ...l components e g electrolytic capacitors EEPROM is used as backup memory when the power is interrupted The write life of the EEPROM is 100 000 writes The EEPROM is written at the following times When...

Page 19: ...OR INAPPROPRIATE MODIFICATION OR REPAIR Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards codes or regulations that apply to the combinati...

Page 20: ...U S A Tel 1 847 843 7900 Fax 1 847 843 7787 Regional Headquarters OMRON EUROPE B V Wegalaan 67 69 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 Contact www ia omron com Tokyo...

Reviews: