Safety Precautions for All H7CZ Series (Common)

Do not allow pieces of metal, wire clippings, or fine 
metallic shavings or fillings from installation to enter 
the product. Doing so may occasionally result in 
electric shock, fire, or malfunction.

Minor injury due to explosion may occasionally occur. 
Do not use the Counter where subject to flammable or 
explosive gas.

Fire may occasionally occur. Tighten the terminal 
screws to the rated torque.
P2CF Socket terminals: 4.4 lb-in (0.5 N·m)

Minor injury due to electric shock may occasionally 
occur. Do not touch any of the terminals while power 
is being supplied. Be sure to mount the terminal cover 
after wiring.

The life expectancy of the output relay varies 
considerably according to its usage. Use the output 
relay within its rated load and electrical life 
expectancy. If the output relay is used beyond its life 
expectancy, its contacts may become fused or there may be a 
risk of fire. Also, be sure that the load current does not exceed 
the rated load current and when using a heater, be sure to use a 
thermal switch in the load circuit.

Minor electric shock, fire, or malfunction may 
occasionally occur. Do not disassemble, modify, or 
repair the Counter or touch internal components.

• The panel surface of the H7CZ is water-resistant (conforming to 

NEMA4, IP66, UL Type 4X (Indoor Use Only). To protect the 
internal circuits from water penetration through the space between 
the H7CZ and operating panel, waterproof packing is included. 
Attach the Y92F-30 Adapter with sufficient pressure with the 
reinforcing screws so that water does not penetrate the panel.   

• When mounting the Counter to a panel, tighten the two mounting 

screws alternately, a little at a time, so as to keep them at an equal 
tightness. If the panel screws are tightened unequally, water may 
enter the panel.

• Store the Counter at the specified temperature. If the Counter has 

been stored at a temperature of less than 

10

°

C, allow the Counter to stand at room temperature for at least 

3 hours before use.

• Mounting the Counter side-by-side may reduce the life 

expectancies of internal components.

• Use the Counter within the specified ranges for the ambient 

operating temperature and humidity.

• Do not use in the following locations:

• Locations subject to sudden or extreme changes in temperature.
• Locations where high humidity may result in condensation.

• Do not use the Counter outside of the rated ranges for vibration, 

shock, water exposure, and oil exposure.

• Do not use this Counter in dusty environments, in locations where 

corrosive gasses are present, or in locations subject to direct 
sunlight.

• Install the Counter well away from any sources of static electricity, 

such as pipes transporting molding materials, powders, or liquids.

• Internal elements may be destroyed if a voltage outside the rated 

voltage range is applied.

• Be sure that polarity is correct when wiring the terminals. 
• Separate the Counter from sources of noise, such as devices with 

input signals from power lines carrying noise, and wiring for I/O 
signals.

• Do not connect more than two crimp terminals to the same 

terminal.

• Up to two wires of the same size and type can be inserted into a 

single terminals.

• Use the specified wires for wiring. Applicable Wires: AWG 18 to 

AWG 22, solid or twisted, copper

• Install a switch or circuit breaker that allows the operator to 

immediately turn OFF the power, and label it to clearly indicate its 
function.

• Approximately 14 V is output from the input terminals. Use a 

sensor that contains a diode.

• Use a switch, relay, or other contact so that the rated power supply 

voltage will be reached within 0.1 seconds. If the power supply 
voltage is not reached quickly enough, the Counter may 
malfunction or outputs may be unstable.

• Use a switch, relay, or other contact to turn the power supply OFF 

instantaneously. Outputs may malfunction and memory errors may 
occur if the power supply voltage is decreased gradually.

• When changing the set value during operation, because the H7CZ 

uses a constant read-in system, output will turn ON if the set value 
is equal to the present value.

• When changing the comparison value during operation, because 

the H7CZ uses a constant read-in system, the output status will 
change if the comparison value is changed to a value on the other 
side of the present value.

• Do not use organic solvents (such as paint thinners or benzine), 

strong alkali, or strong acids. They will damage the external finish.

• Confirm that indications are working normally, including the LCD. 

The indicator, LCD, and resin parts may deteriorate more quickly 
depending on the application environment, preventing normal 
indications. Periodic inspection and replacement are required.

• The waterproof packing may deteriorate, shrink, or harden 

depending on the application environment. Periodic inspection and 
replacement are required.

 CAUTION

Precautions for Safe Use

0.5 to 1 mm

It is recommended that the 
space between the screw 
head and the Adapter be 
0.5 to 1 mm. 

Input

0 V

Sensor

Diode

Summary of Contents for H7CZ Series

Page 1: ...could be damaged if wired incorrectly The H7CZ removes these worries Set Value Limit You can set an upper limit for the set value to prevent unexpected operation of output devices caused by setting mi...

Page 2: ...er 8 pin socket 1 stage 6 digits Contact output SPDT 100 to 240 VAC H7CZ L8 12 to 24 VDC 24 VAC H7CZ L8D1 Model Page Y92A 48F1 9 Model Page Y92A 48 9 Model Page Y92F 30 9 Model Page Y92S 29 9 Model Ty...

Page 3: ...Output mode N F C R K 1 P Q and A One shot output time 0 01 to 99 99 s Reset system External minimum reset signal width 1 ms or 20 ms selectable Manual and Automatic reset internal according to C R P...

Page 4: ...24 VDC Noise immunity 1 5 kV between power terminals 600 V between input terminals Square wave noise by noise simulator pulse width 100 ns 1 s 1 ns rise Static immunity Malfunction 8 kV Destruction 1...

Page 5: ...cuit IN 14V 1 k Open Collector Voltage Output Contact Input DC Two wire Sensor Note Operates with transistor ON PLC or sensor 1 3 4 0 V for inputs Reset input Count input Note Operates with transistor...

Page 6: ...1 The mounting panel thickness should be 1 to 5 mm 2 To allow easier operation it is recommended that Adapters be mounted so that the gap between sides with hooks is at least 15 mm i e with the panel...

Page 7: ...ent the condition of resin products may deteriorate and may shrink or become harder Therefore it is recommended that resin products are replaced regularly The H7CZ s panel surface is water resistive c...

Page 8: ...t and internal connections Mounting hole dimensions P2CF 08 Top View Note The Socket can also be mounted to DIN track P2CF 08 E Finger Safe Terminal Model Dimensions Terminal arrangement and internal...

Page 9: ...5 10 25 25 1 000 500 The values shown in parentheses are for the PFP 50N Mounting Track PFP 100N PFP 50N 15 25 25 1 000 4 5 25 25 15 10 1 24 27 35 0 3 16 1 5 29 2 10 Mounting Track PFP 100N2 4 8 1 3...

Page 10: ...the individual U Key Set the counting speed using the U Key Set the Reset input signal width using the U Key Set the decimal point position using the U Key One digit after decimal point Two digits aft...

Page 11: ...ual U Key Note The monitor value is only displayed It cannot be set Key protect level KYPT From previous page To previous page Output ON count alarm set value monitor value Set each digit using the in...

Page 12: ...ting a prescale value Set the set value to a value less than Maximum countable value Prescale value Example If the prescale value is 1 25 and the counting range is 0 000 to 999 999 set the set value t...

Page 13: ...n the present value reaches the set value a signal is output according to the specified output mode UP Increment Mode DOWN Decrement Mode Counting starts when the count input is turned ON after turnin...

Page 14: ...et start status The present value display does not show the present value upon count up The outputs repeat one shot operation R The present value display returns to the reset start status after the on...

Page 15: ...s 0 to 999 999 Self holding output One shot The one shot output time can be set in the range 0 01 to 99 99s Input mode Operation after count completion UP DOWN Output mode setting P The present value...

Page 16: ...d if the alarm value setting for either of the two outputs is exceeded if a model with two outputs is used The total ON count will not be cleared by using the Reset Key Level Description Details Chang...

Page 17: ...of the rated ranges for vibration shock water exposure and oil exposure Do not use this Counter in dusty environments in locations where corrosive gasses are present or in locations subject to direct...

Page 18: ...l components e g electrolytic capacitors EEPROM is used as backup memory when the power is interrupted The write life of the EEPROM is 100 000 writes The EEPROM is written at the following times When...

Page 19: ...OR INAPPROPRIATE MODIFICATION OR REPAIR Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards codes or regulations that apply to the combinati...

Page 20: ...U S A Tel 1 847 843 7900 Fax 1 847 843 7787 Regional Headquarters OMRON EUROPE B V Wegalaan 67 69 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 Contact www ia omron com Tokyo...

Reviews: