44
H7CX-R
@
-N
(99.9 s)
(0.0 s)
(Enabled)
(Disabled)
(99999)
(0)
(19.99 s)
(0.00 s)
(999999)
(1)
(999.9 s)
(0.1 s)
kp-1
off
on
0
99999
0.00
19.99
999999
1
kp-2 kp-3 kp-4 kp-5 kp-6 kp-7
0
9999
0
9999
0
9999
Procedure for Models Other than “-R11W
@
” Models
Procedure for “-R11W
@
” Models
(9999
×
1000 times)
(0
×
1000 times)
(KP-1) (KP-2) (KP-3) (KP-4) (KP-5) (KP-6) (KP-7)
*1
Note: Not displayed in AMD-compatible mode.
*1 Set each digit using the individual
U
Key.
Note: The monitor value is only
displayed. It cannot be set.
Output OFF
delay
(OFFD)
Output ON
count alarm set
value/monitor
value
• Set each digit using the individual
U
Key.
Function Setting Mode
Auto-zero
time
(AUTO0)
Startup
time
(STMR)
Peak/bottom
hold
enabled
(DHLD)
Output
hysteresis
(HYS)
Set value
upper limit
(SL-H)
Key
protect
level
(KYPT)
• Set each digit using the individual
U
Key.
• Enable or disable peak/bottom hold using the
U
Key.
• Set the output hysteresis using the
U
Key.
• Set each digit using the individual
U
Key.
Note: The measurement value after prescaling is set.
• Set each digit using the individual
U
Key.
• Set the key protect level using the
U
Key.
Output
ON count
alarm set
value
Output
ON count
monitor
value
Output 1
(OUT1) ON
count alarm
set value
Output 2
(OUT2) ON
count alarm
set value
Note: The monitor value is only
displayed. It cannot be set.
Note: The monitor value is only
displayed. It cannot be set.
Output 1
(OUT1) ON
count
monitor
value
Output 2
(OUT2) ON
count
monitor
value
(9999
×
1000 times)
(0
×
1000 times)
(9999
×
1000 times)
(0
×
1000 times)
(MV)
(SMP)
(99.999)
(1.000)
(0.001)
The characters displayed in reverse video are the default settings.
smp
mv
Power ON
Run mode
Step2
Change to Function Setting Mode.
3 s min.
*2
3 s min.
*1
• Set the decimal point position using the
U
Key.
*1 If the mode is switched to the function setting mode during operation, operation will
continue.
*2 Changes made to settings in function setting mode are enabled for the first time when the
mode is changed to run mode.
Also, when settings are changed, the counter is reset (measured values initialized and
output turned OFF) on returning to run mode.
Function
setting mode
Averaging
method
(AUGT)
Prescale value
(PSCL)
Decimal point
position
(DP)
(No decimal point) (One digit after
decimal point)
(Two digits after
decimal point)
(Three digits after
decimal point)
• Set each digit using the individual
U
Key.
• Set the averaging method using the
U
Key.
Note: Not displayed in AMD-compatible mode.
Note: SMP: Simple averaging, MV: Moving average
For details on operations in run mode, refer to page page 47.