![background image](http://html1.mh-extra.com/html/omron/gi-smd-sid/gi-smd-sid_quick-start-manual_743068002.webp)
GI-SMD/SID
2
Specifications
Regulations and Standards
GI-S-series safety I/O terminals
• The FSoE protocol was certified for applications in which OMRON FSoE devices are connected to each other.For compatibility with FSoE
devices other than OMRON FSoE devices, the customer must validate FSoE communications.
By using GI-S-series safety I/O terminals, you can build a safety control system that meets the followings.
• Requirements for SIL 3 (Safety Integrity Level 3) in IEC 61508, IEC/EN 62061, (Functional Safety of Electrical/Electronic/Programmable
Electronic Safety-related Systems)
• Requirements for PLe (Performance Level e) and for safety category 4 in EN ISO13849-1
Also, GI-S-series safety I/O terminals have been registered for conformity to RCM, EAC, and KC (Korean radio regulation).
General Specifications
Certification body
Standards
TÜV Rheinland
• EN ISO 13849-1
• IEC 61508 parts 1-7
• IEC/EN 62061
• IEC/EN 61131-2
UL
• NRAG (UL 61010-1, UL 61010-2-201 and UL 121201)
• NRAG7 (CSA C22.2 No. 61010-1, CSA C22.2 No. 61010-2-201 and CSA C22.2 No. 213)
Item
Specification
Enclosure
Mounted in a panel (open type)
Operating
environment
Ambient operating temperature
0 to 55°C
Ambient operating humidity
10% to 95% (with no condensation or icing)
Atmosphere
Must be free from corrosive gases
Ambient storage temperature
−
25 to 70°C (with no condensation or icing)
Altitude
2,000 m max.
Pollution degree
2
Insulation class
CLASS III (SELV)
Overvoltage category
II
EMC immunity level
Zone B: IEC 61131-2
Vibration resistance
Conforms to IEC 60068-2-6
5 to 8.4 Hz with amplitude of 3.5 mm
8.4 to 150 Hz, acceleration of 9.8 m/s
2
100 min. in each X, Y, and Z directions (10 sweeps of 10 min. each = 100 min. total)
Shock resistance
Conforms to IEC 60068-2-27
147 m/s
2
3 times in each X, Y, and Z directions
Insulation resistance
20 M
Ω
between isolated circuits (at 100 VDC)
Dielectric strength
500 VAC between isolated circuits for 1 minute at a leakage current of 10 mA max.
Installation method
DIN Track mounting (IEC 60715 TH35-7.5/TH35-15)
Degree of protection
IP20