background image

J-72

Solid State Relays 

G3R-I/O

Dimensions

Note:

All units are in millimeters unless otherwise indicated.

G3R

Connecting Sockets

Connecting Socket Attaching Plates

4

5

7.5

9.6

3

4

1

2

20

0.5

5.2

17.4

4.7

4.75

4.75

0.5

10

1

5

(+)

(

)

3

4

1

5

(

)

(+)

13 max.

28 max.

29 max.

Load

Input

Terminal Arrangement/ 
Internal Connections 
(Bottom View)

58.5 *

Five, M3.5

×

8

12

P2RF-05

71.5 max.

19.5 max.

54 max.

30 max.

4 dia.

4.2-dia. hole

P2RF-05 Socket

G3R I/O Relay

M3 (M3 x16) or 
3.2-dia. hole

*   Indicates a value when using the PFP-

@

Supporting Rail. 
The value is 67.5 when using the PFP-

@

N2.

62.5 ** 
(66.5)***

P2RF-05-E

G3R I/O Relay

3.2-dia. hole

M3 or 3.5-dia. hole

59 max.

48 max.

M3.5 screw

85.5 max.

61 max.

3.5-dia. 
hole

PFRF-05-E 
Socket

**   Indicates a value when using the PFP-

@

Supporting Rail with the P2RF-05-E 
The value is 71.5 when using the PFP-

@

N2.

***  Indicates a value when using the PFP-

@

Supporting Rail with the P2RF-08-E 
The value is 75.5 when using the PFP-

@

N2.

P2R-05A

14.5 max.

35.5 max.

Five, 3x1.5-dia. hole

G3R I/O Relay

P2R-05A Socket

36 max.

(Panel thickness must 
be 1.6 to 2.0 mm.)

Summary of Contents for G3R-I-O

Page 1: ...el Number Structure Model Number Legend 1 Basic Model Name G3R Solid State Relay 2 I O Classification I Input module O Output module 3 Load Power Supply Type A Switches AC loads D Switches DC loads 4...

Page 2: ...Model Supply voltage Supply current Photocoupler Yes 4 to 32 VDC 0 1 to 100 mA 100 to 240 VAC G3R IAZR1SN UTU High speed 1 kHz 5 VDC G3R IDZR1SN UTU 12 to 24 VDC Low speed 10 Hz 5 VDC G3R IDZR1SN 1 UT...

Page 3: ...1SN UTU 5 VDC 4 to 6 VDC 8 mA max 4 VDC max 1 VDC min 12 to 24 VDC 6 6 to 32 VDC 6 6 VDC max 3 6 VDC min G3R IDZR1SN 1 UTU 5 VDC 4 to 6 VDC 4 VDC max 1 VDC min 12 to 24 VDC 6 6 to 32 VDC 6 6 VDC max 3...

Page 4: ...35 T V File No R9650094 EN60950 Ambient humidity Operating 45 to 85 Weight Approx 18 g Item G3R OA202SZN UTU G3R OA202SLN UTU G3R ODX02SN UTU G3R OD201SN UTU Operate time 1 2 of load power source cycl...

Page 5: ...note 2 G3R OA202SZN UTU OA202SLN UTU G3R OD201SN UTU 40 to 200 VAC G3R ODX02SN UTU 4 to 60 VDC Ambient temperature C Load current A Ambient temperature C Load current A Ambient temperature C Load cur...

Page 6: ...I O Relay M3 M3 x16 or 3 2 dia hole Indicates a value when using the PFP N Supporting Rail The value is 67 5 when using the PFP N2 62 5 66 5 P2RF 05 E G3R I O Relay 3 2 dia hole M3 or 3 5 dia hole 59...

Page 7: ...Mounting Plate when arranging several Sockets in a row P2R 05P Dimensional tolerance is 0 1 G3R I O Relay P2R 05P Socket Five 1 6 dia hole 35 5 max 14 5 max 36 max P2R 057P G3R I O Relay P2R 057P Soc...

Page 8: ...Note All units are in millimeters unless otherwise indicated Classification Internal I O circuit common Rated voltage Model Output NPN common 24 VDC G70A ZOC16 3 PNP common 24 VDC G70A ZOC16 4 Input N...

Page 9: ...Solid State Relays G3R I O J 75 SSR Terminal Arrangement Internal Connection G70A ZOC16 3 NPN Connector Terminal Arrangement Top View G70A ZOC16 4 PNP Connector Terminal Arrangement Top View...

Page 10: ...switching the load can be connected to either positive or negative output terminal of the SSR Protective Element Since the SSR does not incorporate an overvoltage absorption component be sure to conn...

Reviews: