background image

G3PJ

2

Specifications

Ratings

Input (at an Ambient Temperature of 25°C)

Output

*

For close mounting of three SSRs.

Characteristics

Applicable Standards

cULus and TÜV (EN 60947-4-3)
Pollution category 2
RoHS compliant

Item

Model

Rated voltage

Operating voltage 

range

Current

Must operate 

voltage

Must release 

voltage

G3PJ-2

@@

B(-PU)/

G3PJ-5

@@

B(-PU)

12 to 24 VDC

9.6 to 30 VDC

7 mA max.

9.6 VDC max.

1.0 VDC min.

Item

Model

Rated load voltage

Load voltage 

range

Load current

Inrush current resistance

I

2

t

G3PJ-215B(-PU)

24 to 240 VAC

50/60 Hz

19 to 264 VAC

50/60 Hz

Close mounting 

*

: 15 A, 

Separate mounting: 18 A

150 A (60 Hz, 1 cycle)

260A

2

s

G3PJ-225B(-PU)

Close mounting 

*

: 25 A,

Separate mounting: 27 A

220 A (60 Hz, 1 cycle)

1,260A

2

s

G3PJ-515B(-PU)

100 to 480 VAC

50/60 Hz

75 to 528 VAC

50/60 Hz

Close mounting 

*

: 15 A,

Separate mounting: 23 A

150 A (60 Hz, 1 cycle)

1,350A

2

s

G3PJ-525B(-PU)

Close mounting 

*

: 25 A,

Separate mounting: 27 A

220 A (60 Hz, 1 cycle)

6,600A

2

s

Model

Item

G3PJ-2

@@

B(-PU)

G3PJ-5

@@

B(-PU)

Operate time

1/2 of load power source cycle + 1 ms max.

Release time

1/2 of load power source cycle + 1 ms max.

Output ON voltage drop

1.6 V (RMS) max.

1.8 V (RMS) max.

Leakage current

10 mA max. (at 240 VAC)

20 mA max. (at 480 VAC)

Insulation resistance

100 M

 min. (at 500 VDC)

Dielectric strength

2,500 VAC 50/60 Hz for 1 min

4,000 VAC 50/60 Hz for 1 min

Vibration resistance

10 to 55 to10 Hz, 0.35 mm single amplitude (0.7 mm double amplitude) (Mounted to DIN track)

Shock resistance

Destruction: 300 m/s

2

 (Mounted to DIN track)

Ambient storage 
temperature

-30 to 100°C (with no icing or condensation)

Ambient operating 
temperature

-30 to 80°C (with no icing or condensation)

Ambient operating humidity

45% to 85%

Weight

Approx. 240 g

Summary of Contents for G3PJ Series

Page 1: ...t have been certified for safety standards refer to your OMRON website Refer to Safety Precautions on page 5 Input terminal Output terminal Insulation method Operation indicator Rated input voltage Ze...

Page 2: ...C 50 60 Hz 75 to 528 VAC 50 60 Hz Close mounting 15 A Separate mounting 23 A 150 A 60 Hz 1 cycle 1 350A2 s G3PJ 525B PU Close mounting 25 A Separate mounting 27 A 220 A 60 Hz 1 cycle 6 600A2 s Model I...

Page 3: ...0 0 20 40 60 80 100 Ambient temperature C Load current A G3PJ 225B PU G3PJ 525B PU G3PJ 215B PU G3PJ 515B PU 30 20 0 20 40 60 80 100 Ambient temperature C 40 30 20 12 10 8 5 0 G3PJ 215B PU G3PJ 515B P...

Page 4: ...c r i c r e g g i r T Input side Input side Output side t i u c r i c r e g g i r T t i u c r i c t u p n I t i u c r i c t u p n I 2 M4 26 5 41 5 4 2 6 1 Note Without terminal cover 68 13 0 2 100 ma...

Page 5: ...during transportation or mounting Doing so may result in deterioration of performance malfunction or failure Operating and Storage Environments Do not use or store the G3PJ in the following locations...

Page 6: ...pull on it with excessive force Doing so may cause the wire disconnection Do not insert more than one wire into each terminal insertion hole To prevent wiring materials from smoking or ignition use t...

Page 7: ...it is too thin use a flat blade screwdriver in the same way as when connecting stranded wire Connecting Stranded Wires Use the following procedure to connect the wires to the terminal 1 Hold a flat bl...

Page 8: ...nnected to the load power supply The input cable must be less than 3 m 2 The G3PJ with Rated Load Voltage of 100 to 480 VAC 5 B model A capacitor must be connected to the input power supply A capacito...

Page 9: ...is measured at an ambient temperature of 40 C The G3PJ uses a semiconductor to switch the load This causes the temperature inside the control panel to increase due to heating resulting from the flow o...

Page 10: ...MEMO 10...

Page 11: ...CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED IN CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY Further in no event shall liability of Omron Companies exceed the individual price of the Pr...

Page 12: ...L 60169 U S A Tel 1 847 843 7900 Fax 1 847 843 7787 Regional Headquarters OMRON EUROPE B V Wegalaan 67 69 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 Contact www ia omron c...

Reviews: