background image

J-18

Solid State Relays 

G3NE

Ordering Information

List of Models

Note:

When ordering, specify the input voltage.

Accessories (Order Separately)

Heat Sinks

The following heat sinks are thin and can be DIN-track mounted.
See 

Dimensions

 for details.

Specifications

Ratings (at an Ambient Temperature of 25

°

C)

Input

Note:

Each model has 5-VDC, 12-VDC, and 24-VDC input versions.

Output

Note: 1.

The load current varies depending on the ambient temperature. Refer to L

oad Current vs. Ambient Temperature

 under 

Engineering Data

 

for details.

2.

These values apply when using a dedicated heat sink or a radiation plate of specified size.

Isolation

Zero cross 

function

Indicator

Rated output load

Rated input voltage

Model

Phototriac

Yes

No

5 A at 100 to 240 VAC 

5, 12, 24 VDC

G3NE-205T-US
G3NE-205T-2-US

10 A at 100 to 240 VAC 

G3NE-210T-US
G3NE-210T-2-US

20 A at 100 to 240 VAC 

G3NE-220T-US
G3NE-220T-2-US

No

5 A at 100 to 240 VAC 

G3NE-205TL-US
G3NE-205TL-2-US

10 A at 100 to 240 VAC 

G3NE-210TL-US
G3NE-210TL-2-US

20 A at 100 to 240 VAC 

G3NE-220TL-US
G3NE-220TL-2-US

Model

Applicable SSR

Y92B-N50

G3NE-205T(L)(-2)-US/-210T(L)(-2)-US

Y92B-N100

G3NE-220T(L)(-2)-US

Rated voltage

Operating voltage

Voltage level

Input impedance

Must operate

Must release

With zero cross function Without zero cross function

5 VDC

4 to 6 VDC

4 VDC max.

1 VDC min.

250 

Ω±

20%

300 

Ω±

20%

12 VDC

9.6 to 14.4 VDC

9.6 VDC max.

600 

Ω±

20%

800 

Ω±

20%

24 VDC

19.2 to 28.8 VDC

19.2 VDC max.

1.6 k

Ω±

20%

Model

Applicable load

Rated load voltage

Load voltage range

Load current

(See note 1.)

Inrush current

With heat sink

Without heat sink

G3NE-205T(L)(-2)-US

100 to 240 VAC

75 to 264 VAC

0.1 to 5 A

0.1 to 5 A

60 A (60 Hz, 1 cycle)

G3NE-210T(L)(-2)-US

0.1 to 10 A 
(See note 2.)

0.1 to 5 A

150 A (60 Hz, 1 cycle)

G3NE-220T(L)(-2)-US

0.1 to 20 A 
(See note 2.)

0.1 to 5 A

220 A (60 Hz, 1 cycle)

Reviews: