background image

Safety Design of F3SN-A

3

Complete Safety Design

Output turns OFF via self diagnostics.

Highest Level Safety Design 
Prevents Mechanical Accidents

Safety Design Backed by Technology

Pursuing safety with the highest level of 
safety design and FMEA

Conforms to Global Safety 
Standards for Safety Sensors

Emitter

Receiver

STOP!

Monitor

Control block

Monitor

Control block

Monitor

Output block

Control block

Block diagram of the circuit

Emitter

Receiver

CPU

CPU

Amp.

If a problem occurs, 
the F3SN-A/F3SH-A ensures 
that the machinery will stop 
by outputting the same OFF 
signal as when an intrusion 
is detected.

We pursued the safety of F3SN-A/F3SH-A to the limit with 
the mutual check of two CPUs, safe design by dual circuits 
of signal control and output, and FMEA*, which verifies 
the safety of the operations.

*FMEA : Failure Mode & Effects Analysis

Type 4 Level Sensor Specified by IEC and EN Standards

Conforms to the now mandatory international standards for 
safety sensors: IEC61496-1, IEC61496-2, and EN61496-1. The 
F3SN-A and F3SH-A are type 4 Sensors meeting the highest 
safety standards of category 4.

Conforms to EU Machinery Directives

Certification for EC type-examination in accordance with the EU 
Machinery Directive and conformity to EMC Directives has been 
obtained from DEMKO. The F3SN-A/F3SH-A can be used with 
confidence in machinery and equipment destined for Europe.

Certification for United States and 
Canada from UL in the United States 

Can be used with machinery designed for OSHA regulations and ANSI standards.

Certified for UL Listing based on UL508, IEC61496-1, and 
IEC61496-2 and UL Listing for Canadian safety standards. Can be 
used with machinery that will be used under OSHA regulations 
(29 CFR 1910. 212), which are stipulated under the Occupational 
Safety and Health Act of 1970. Also fulfills the requirements for 
ANSI/RIA R15.06-1999, the United States Safety Requirements 
for Industrial Robots and Robot Systems. The F3SN-A/F3SH-A 
can be confidently used with machinery and equipment bound 
for the United States and Canada.

IEC61496-2

IEC61496-1

Type

4

IEC61496-1
IEC61496-2

Type

4

UL

UL

Damage to receiving elements

Damage to power supply or circuit

Damage of receiving circuit

Faulty CPU

Interference light

Damage of output drive circuit

Damage of output

Open or short-circuited cable

Also supports EDM(External Device 
Monitoring) function.

Damage of emitting circuit

Damage to emitting elements

Faulty CPU

Open or short-circuited cable

Output block

Emitting part

Receiving part

F3SN-A/F3SH-A automatically 
checks for internal circuit 
problems, open or 
short-circuited cables, and 
abnormal incident light. 

Summary of Contents for F3SH-A -

Page 1: ...ht Curtain F3SN A Multi beamSafety Sensor F3SH A The red light beams are intended only to express the light source The beams are not actually visible The gold color shows our confidence in the safety...

Page 2: ...afety Sensor for Every Application OMRON provides safety two ways The Safety Light Curtain and the Multi beam Safety Sensor Body Protection Multi beam Safety Sensor F3SH A09P03 Operating range 10 m No...

Page 3: ...ective and conformity to EMC Directives has been obtained from DEMKO The F3SN A F3SH A can be used with confidence in machinery and equipment destined for Europe Certification for United States and Ca...

Page 4: ...30 mm in a Type 4 Safety Light Curtain with built in amp The new F3SN A F3SH A is 25 smaller than earlier OMRON models Select the Perfect Length Select a detection capability of either 14 mm diameter...

Page 5: ...connector You can create a 3 set system by just wiring one set no need to wire three sets separately as was required with earlier models This facilitates protection for all dangerous machine and devi...

Page 6: ...indicator 6 Setting Console All Functions Can be Set Easily and Safely Password Protection Prevents inadvertent changes to settings Easy Function Settings Monitoring and Copying to Multiple Sensors I...

Page 7: ...ator Output Can select external indicator output from Dark ON Light ON Light diagnosis and Lockout EDM External Device Monitoring function Monitors for external relay contact welding Interlock Functio...

Page 8: ...300 mm gap using 4 beams Detects whole body intrusion The EN999 Standard concerns machine safety in particular the positioning of protective devices in relation to the approach speed of part of a hum...

Page 9: ...open or causes other errors The Interlock selection input line or the reset input line is not wired correctly or becomes open Relay contact is welded Releasing time of the relay takes too long The EDM...

Page 10: ...2 to 7m 13 to 120 No Yes 25mm 15mm 1 The oooo in the model numbers indicates the protective height in mm 2 F3SN A oooo P14 01 is a customized model produced at the OMRON plant Consult with your dealer...

Page 11: ...series connection models Specification F39 JCR2B F39 JC3B F39 JC7B F39 JC10B F39 JC15B Model Application Appearance Model F39 A01PR L F39 A01PG L F39 A01PR D F39 A01PG D red green Indicator Emitter Re...

Page 12: ...811 0 Fax 49 7032 811 199 OMRON ELECTRONICS LLC 1 East Commerce Drive Schaumburg IL 60173 U S A Tel 1 847 843 7900 Fax 1 847 843 8568 OMRON ASIA PACIFIC PTE LTD 83 Clemenceau Avenue 11 01 UE Square 23...