5-2
5-1 LED indication on receiver unit
F3ET2 LIGHT CURTAINS OPERATION MANUAL
5
LED indicators and error indication
Meaning of symbols
5-1 LED indication on receiver unit
Status of Receiver is displayed by 5 LEDs:
Normal operation indication on receiver:
LED error indication on receiver:
SYMBOL
MEANING
Diagnosis LED off
Diagnosis LED on
Diagnosis LED blinking
Disposition of indicator
Name of indicator
Colour
POWER
Green
RUN
Yellow
FREE
Green
BREAK
Red
STATUS
Yellow
POWER RUN FREE BREAK ST
AT
US
RX
LED signal pattern
Description
No object in field. Running ok
Object in field. Running ok
Correct alignment reached
ID
LED signal pattern
Description
1
Short on PNP/NPN output
2
Low supply voltage
3
Error on microcontroller
4
Error on optical system
5
Wrong dip switch configuration