background image

7

F3EM

 Measuring lightcurtain in robust aluminium housing

Precautions

Power Supply Voltage and 
Output Load Power Supply Voltage

Do not connect an AC power supply to the Sensor. If AC pow-
er (100 VAC or more) is supplied to the Sensor, it may ex-
plode or burn. Make sure that the power supply to the Sensor 
is within the rated voltage range. If a voltage exceeding the 
rated voltage range is supplied to the Sensor, it may explode 
or burn.

Operating Environment

Do not use the sensor in locations with explosive or flamma-
ble gas. Make sure that the product is operated in accordance 
with IP65 standards.

Do not subject the sensor to excessive shock when mounting.

When you use the sensor in the vicinity of an inverter motor, 
be sure to connect the protective earth ground wire of the mo-
tor to earth. Failure to ground the motor may result in malfunc-
tion of the sensor.

Mounting the Sensor

Do not strike the sensor with a hammer or any other tool dur-
ing the installation of the Sensor.

Cleaning

Never use paint thinners or other organic solvents to clean the 
surface of the product

M12 Connector

Always turn OFF the power supply to the sensor before con-
necting or disconnecting the metal connector. Hold the con-
nector cover to connect or disconnect it. 

Secure the connector cover by hand. Do not use pliers; other-
wise the connector may be damaged.

If the connector is not connected securely, it may be discon-
nected by vibration or the proper degree of protection of the 
sensor may not be maintained.

@

 

WARNING

The F3EM multi-beam photoelectric sensor with beam
evaluation function is not a safety component for en-
suring the safety of people which is defined in EC di-
rective (2006/42/EC) or by any other regulations or
standards. 

Summary of Contents for F3EM

Page 1: ...Sensing distance Chan nels Connection method Order code Analog output RS232 output2 2 Models with RS485 serial output are available Contact your OMRON representative Through beam measur ing 150 5 mm 3...

Page 2: ...mm MaxM 150 300 600 900 21002 2 Models with different measurement ranges between 150 mm and 2100 mm are available in 150 mm intervals Minimum detectable object size 10 mm 30 mm Pitch 5 mm 18 mm Contro...

Page 3: ...Terminal 2 4 and 5 are not used 24 VDC 0 V Brown Grey White 0 10 V Black Blue 1 5 2 4 3 Main circuit D A Converter Out OFF red Out ON green Run OK yellow Power green Near Far yellow 2 3 4 1 5 24 VDC...

Page 4: ...elector switches dip switches Operation mode distance setting analog models and trans mission speed serial models can be changed by selector switches To access selector switches unscrew the end cap of...

Page 5: ...mand response mode the command is 1 byte Command hexadecimal BF The light curtain responds with a fixed number of bytes de pending on the number of light beams E g the response of a light curtain with...

Page 6: ...ADJ For adjustment of the optical axis angle the adjustable mounting bracket allows a turning of the light curtain Laser Alignment Order separately under F39 TGR LLK2 SB The laser alignment kit can b...

Page 7: ...round wire of the mo tor to earth Failure to ground the motor may result in malfunc tion of the sensor Mounting the Sensor Do not strike the sensor with a hammer or any other tool dur ing the installa...

Page 8: ...ousing In the interest of product improvement specifications are subject to change without notice Cat No E62E EN 01A OMRON EUROPE B V Wegalaan 67 69 NL 2132 JD Hoofddorp The Netherlands Phone 31 23 56...