background image

3

F3EM

 Measuring lightcurtain in robust aluminium housing

Output circuits

Type

Output circuit

Receiver analog output

Connector pin arrangement

Receiver serial output

Connector pin arrangement

Emitter

Connector pin arrangement

Note: Terminal 2, 4 and 5 are not used

24 VDC

0 V

Brown

Grey

White

0-10 V

Bl

a

ck

Bl

u

e

1

5

2

4

3

Main 

circuit

D/A

Converter

O

u

t OFF

(red)

O

u

t ON

(green)

R

u

n OK

(yellow)

Power
(green)

Ne

a

r/F

a

r

(yellow)

+

-

2

3

4

1

5

24 VDC

0 V

Brown

Grey (

S

tro

b

e Inp

u

t)

Bl

a

ck

RxD

Bl

u

e

1

5

2

4

3

Main 

circuit

O

u

t OFF

(red)

O

u

t ON

(green)

R

u

n OK

(yellow)

Power
(green)

Ne

a

r/F

a

r

(yellow)

White

TxD

2

3

4

1

5

24 VDC

0 V

Brown

Bl

u

e

1

3

Main 

circuit

S

t

a

t

us

 OK

(yellow)

Power
(green)

2

3

4

1

5

Summary of Contents for F3EM

Page 1: ...Sensing distance Chan nels Connection method Order code Analog output RS232 output2 2 Models with RS485 serial output are available Contact your OMRON representative Through beam measur ing 150 5 mm 3...

Page 2: ...mm MaxM 150 300 600 900 21002 2 Models with different measurement ranges between 150 mm and 2100 mm are available in 150 mm intervals Minimum detectable object size 10 mm 30 mm Pitch 5 mm 18 mm Contro...

Page 3: ...Terminal 2 4 and 5 are not used 24 VDC 0 V Brown Grey White 0 10 V Black Blue 1 5 2 4 3 Main circuit D A Converter Out OFF red Out ON green Run OK yellow Power green Near Far yellow 2 3 4 1 5 24 VDC...

Page 4: ...elector switches dip switches Operation mode distance setting analog models and trans mission speed serial models can be changed by selector switches To access selector switches unscrew the end cap of...

Page 5: ...mand response mode the command is 1 byte Command hexadecimal BF The light curtain responds with a fixed number of bytes de pending on the number of light beams E g the response of a light curtain with...

Page 6: ...ADJ For adjustment of the optical axis angle the adjustable mounting bracket allows a turning of the light curtain Laser Alignment Order separately under F39 TGR LLK2 SB The laser alignment kit can b...

Page 7: ...round wire of the mo tor to earth Failure to ground the motor may result in malfunc tion of the sensor Mounting the Sensor Do not strike the sensor with a hammer or any other tool dur ing the installa...

Page 8: ...ousing In the interest of product improvement specifications are subject to change without notice Cat No E62E EN 01A OMRON EUROPE B V Wegalaan 67 69 NL 2132 JD Hoofddorp The Netherlands Phone 31 23 56...

Reviews: