background image

E8MS/E8M

11

Nomenclature

Pressure Sensor Controller

E8M-MP8

Switch output indicators (red): Lit when OUT1 (CH1 to CH4) and OUT2 (CH1 only) are ON.
LCD display (orange): 

Displays the present pressure status, setting mode status, display unit, and error code.

Up Button: 

Used to select the mode and increase ON/OFF set values.

Down Button: 

Used to select the mode and decrease ON/OFF set values.

SET Button: 

Used to change modes and enter set values.

Unit indicators (orange): 

The selected unit indicator will light. Only the SI units (i.e., Mpa or kPa) can be used. 

Channel display (red): 

The channel selected from CH1 to CH4 is displayed.

Accessories

Panel Mounting Adapter . . . . . . . . . . . . . . . . . . . . . . Y92F-37-S (M3 x 8L, two provided)

Options

Power and Output Connector Cable (2 m)   . . . . . . . E89-M5-S

Protective Front Cover . . . . . . . . . . . . . . . . . . . . . . . Y92A-40-S
48 x 48 Adapter  . . . . . . . . . . . . . . . . . . . . . . . . . . . . Y92F-48-S
(This Adapter is to mount the E8M-MP8 in the panel cutout dimensions for the K3C Series.)

Unit indicator (orange)

LCD display (orange)

Channel display (red)

Switch output indicators (red)

Up Button

SET Button

Down Button

Sensor Connector

Power and Output Connector Cable

Water-proof Packing (Accessory)

Protective Front Cover

48 x 48 Adapter

Panel Mounting Adapter (Accessory)

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Summary of Contents for E89-M3-S

Page 1: ...tion Model Positive pressure 0 to 100 kPa Linear output 1 to 5 V E8MS 01 0 to 1 MPa E8MS 10 Negative pressure 0 to 101 kPa E8MS N0 Compound pressure 101 to 101 kPa E8MS N1 Pressure range Output config...

Page 2: ...connector with 3 m long cable E8MS E80 C2 E89 M4 1 3 conductor 3 m long cable with connectors on both ends Cannot be cut or extended Appearance Model Applicable wire size mm2 Quantity Minimum order u...

Page 3: ...0 to 50 C Storage 15 to 60 C with no icing Ambient humidity range Operating Storage 35 to 85 with no condensation Temperature influence 0 12 FS C max Voltage influence 1 FS max Insulation resistance...

Page 4: ...range Operating Storage 35 to 85 with no condensation Temperature influence 0 25 FS C max 0 12 FS C max Voltage influence 3 FS max Insulation resistance 100 M min at 500 VDC between current carrying p...

Page 5: ...r 1 digit Comparative output LED indicator red that is lit when the output transistor is turned ON Others LED indicator green for connecting channel and unit display green Response speed 5 ms max The...

Page 6: ...Pa Linear output voltage V 5 4 3 2 1 0 20 40 60 80 101 Pressure kPa Linear output voltage V 5 4 3 2 1 0 200 400 600 800 1 000 Differential pressure Pa between positive and negative ports Linear output...

Page 7: ...2 3 4 5 0 20 40 60 80 101 E8MS N0 E8M N0 Pressure kPa Linearity deviation FS 5 4 3 2 1 0 1 2 3 4 5 0 200 400 600 800 1 000 Differential pressure Pa between positive and negative ports Linearity devia...

Page 8: ...0 5 10 5 11 11 5 12 12 5 13 13 5 Voltage V Rated pressure Pressure 0 Linear output fluctuation FS 0 5 0 4 0 3 0 2 0 1 0 0 1 0 2 0 3 0 4 0 5 10 5 11 11 5 12 12 5 13 13 5 Voltage V Rated pressure Press...

Page 9: ...30 40 50 Temperature C Pressure 0 Rated pressure Linear output fluctuation FS 5 4 3 2 1 0 1 2 3 4 5 10 0 10 20 30 40 50 Temperature C Pressure 0 Rated pressure Linear output fluctuation FS 5 4 3 2 1...

Page 10: ...tor green Output configuration Model Output circuit NPN output E8M MP8 Note The wire colors shown on the left are the wire colors of the E89 M5 S Controller power supply output connector cables 24 VDC...

Page 11: ...Panel Mounting Adapter Y92F 37 S M3 x 8L two provided Options Power and Output Connector Cable 2 m E89 M5 S Protective Front Cover Y92A 40 S 48 x 48 Adapter Y92F 48 S This Adapter is to mount the E8M...

Page 12: ...crews to a torque no more than 3 9 N m 3 Tighten M5 female screws to a torque no more than 1 to 1 5 N m 4 When tightening a screw hold by its hexagonal head not by its body E8M N0 1 The pressure port...

Page 13: ...1 Do not use the Sensor in an environment subject to corrosive or combustible gases 2 Do not use the Sensor alongside a high tension voltage line or power line 3 Do not expose the Sensor to water 4 B...

Page 14: ...together with the E8M A1 S E8M 10 M8 hexagonal nut M5 R1 8 Pressure port 16 7 24 37 5 13 5 13 1 4 Connector B04B XASK by JST Mfg Co Ltd 20 6 Power indicator green 4 9 dia 27 5 dia 9 2 8 2 10 Connectio...

Page 15: ...conductors Standard length 3 m Note One XN2A 1430 is provided with the E89 M3 S For the E8MS Only E89 M4 S Note One XN2A 1430 is provided with the E89 M4 S 50 3 000 30 10 3 2 50 2 9 dia vinyl insulat...

Page 16: ...15 43 9 17 8 40 2x40 2 Hard Protective Front Cover Y92A 40 S 42 4x42 4 46 4 Display surface 36 4x36 4 48x48 Panel Hole Adapter Y92F 48 S 48x48 37x37 3 5 2 Downloaded from Arrow com Downloaded from Ar...

Page 17: ...on systems medical equipment amusement machines vehicles safety equipment and installations subject to separate industry or government regulations Systems machines and equipment that could present a r...

Reviews: