E8M

* The absolute pressure value of each port is 100 kPa.

Item

Model

E8M-A1-S

E8M-10

E8M-N0

Power supply voltage

12 VDC ±10%, ripple (p-p) of 5% max.

Current consumption

30 mA max.

Pressure type

Differential pressure

Gauge pressure

Applicable fluid

Non-corrosive gas and non-flammable gas

Rated pressure range

Differential pressure from 0 to 
1,000 Pa between positive and 
negative ports

0 to 1 MPa

0 to 

101 kPa

Withstand pressure

Differential pressure from 0 to 
2,500 Pa between positive and 
negative ports 

*

1.5 MPa

400 kPa

Accuracy

±3% FS max.

±5% FS max.

Linearity

±1% FS max.

Hysteresis

±1% FS max.

Linear output

Voltage output: 1 to 5 V with an output impedance of 1 k

Protection circuits

Reverse polarity protection, load short-circuit protection

Ambient temperature 
range

Operating: 0 to 40°C 
Storage: 

15 to 50°C (with no icing)

Ambient humidity range

Operating/Storage: 35% to 85% (with no condensation)

Temperature influence

±0.25% FS/°C max.

±0.12% FS/°C max.

Voltage influence

±3% FS max.

Insulation resistance

100 M

 min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

1,000 VAC for 1 minute

Vibration resistance 

Destruction: 10 to 150 Hz, 0.75-mm single amplitude or 100 m/s

2

, 4 times each for 8 min in X, Y and Z directions

Shock resistance

Destruction: 300 m/s

2

 3 times each in X, Y and Z directions

Degree of protection

 IP50 (IEC60529)

Pressure port

M5 female screw

R (PT) 1/8 and M5 female screw

M5 male screw

Connection method

Pre-wired cable 
(standard length: 3 m)

Connector

Weight (packed state)

Approx. 130 g

Approx. 30 g

Approx. 20 g

Material

Pressure port

Stainless steel (SUS303)

Stainless steel (SUS304)

Case

ABS

Aluminum, polyether sulfonic resin

Accessories

Pin Controller Connector, 
instruction manual

Instruction manual

Pressure  
generator

E8M-A1

100 mm

Measurement method

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Summary of Contents for E89-M3-S

Page 1: ...tion Model Positive pressure 0 to 100 kPa Linear output 1 to 5 V E8MS 01 0 to 1 MPa E8MS 10 Negative pressure 0 to 101 kPa E8MS N0 Compound pressure 101 to 101 kPa E8MS N1 Pressure range Output config...

Page 2: ...connector with 3 m long cable E8MS E80 C2 E89 M4 1 3 conductor 3 m long cable with connectors on both ends Cannot be cut or extended Appearance Model Applicable wire size mm2 Quantity Minimum order u...

Page 3: ...0 to 50 C Storage 15 to 60 C with no icing Ambient humidity range Operating Storage 35 to 85 with no condensation Temperature influence 0 12 FS C max Voltage influence 1 FS max Insulation resistance...

Page 4: ...range Operating Storage 35 to 85 with no condensation Temperature influence 0 25 FS C max 0 12 FS C max Voltage influence 3 FS max Insulation resistance 100 M min at 500 VDC between current carrying p...

Page 5: ...r 1 digit Comparative output LED indicator red that is lit when the output transistor is turned ON Others LED indicator green for connecting channel and unit display green Response speed 5 ms max The...

Page 6: ...Pa Linear output voltage V 5 4 3 2 1 0 20 40 60 80 101 Pressure kPa Linear output voltage V 5 4 3 2 1 0 200 400 600 800 1 000 Differential pressure Pa between positive and negative ports Linear output...

Page 7: ...2 3 4 5 0 20 40 60 80 101 E8MS N0 E8M N0 Pressure kPa Linearity deviation FS 5 4 3 2 1 0 1 2 3 4 5 0 200 400 600 800 1 000 Differential pressure Pa between positive and negative ports Linearity devia...

Page 8: ...0 5 10 5 11 11 5 12 12 5 13 13 5 Voltage V Rated pressure Pressure 0 Linear output fluctuation FS 0 5 0 4 0 3 0 2 0 1 0 0 1 0 2 0 3 0 4 0 5 10 5 11 11 5 12 12 5 13 13 5 Voltage V Rated pressure Press...

Page 9: ...30 40 50 Temperature C Pressure 0 Rated pressure Linear output fluctuation FS 5 4 3 2 1 0 1 2 3 4 5 10 0 10 20 30 40 50 Temperature C Pressure 0 Rated pressure Linear output fluctuation FS 5 4 3 2 1...

Page 10: ...tor green Output configuration Model Output circuit NPN output E8M MP8 Note The wire colors shown on the left are the wire colors of the E89 M5 S Controller power supply output connector cables 24 VDC...

Page 11: ...Panel Mounting Adapter Y92F 37 S M3 x 8L two provided Options Power and Output Connector Cable 2 m E89 M5 S Protective Front Cover Y92A 40 S 48 x 48 Adapter Y92F 48 S This Adapter is to mount the E8M...

Page 12: ...crews to a torque no more than 3 9 N m 3 Tighten M5 female screws to a torque no more than 1 to 1 5 N m 4 When tightening a screw hold by its hexagonal head not by its body E8M N0 1 The pressure port...

Page 13: ...1 Do not use the Sensor in an environment subject to corrosive or combustible gases 2 Do not use the Sensor alongside a high tension voltage line or power line 3 Do not expose the Sensor to water 4 B...

Page 14: ...together with the E8M A1 S E8M 10 M8 hexagonal nut M5 R1 8 Pressure port 16 7 24 37 5 13 5 13 1 4 Connector B04B XASK by JST Mfg Co Ltd 20 6 Power indicator green 4 9 dia 27 5 dia 9 2 8 2 10 Connectio...

Page 15: ...conductors Standard length 3 m Note One XN2A 1430 is provided with the E89 M3 S For the E8MS Only E89 M4 S Note One XN2A 1430 is provided with the E89 M4 S 50 3 000 30 10 3 2 50 2 9 dia vinyl insulat...

Page 16: ...15 43 9 17 8 40 2x40 2 Hard Protective Front Cover Y92A 40 S 42 4x42 4 46 4 Display surface 36 4x36 4 48x48 Panel Hole Adapter Y92F 48 S 48x48 37x37 3 5 2 Downloaded from Arrow com Downloaded from Ar...

Page 17: ...on systems medical equipment amusement machines vehicles safety equipment and installations subject to separate industry or government regulations Systems machines and equipment that could present a r...