Datenblatt

Lichtleiterverstärker E3X-HD

E3X-HD

7

E3X-HD

Heat-resistant Models

Area Detection Models

* The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.

Liquid-level Detection Models

Vacuum-resistant Models

* The fiber length is 1 m on each side, so the sensing distance is given as 2,000 mm.

Models for FPD, Semiconductors, and Solar Cells

* The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.

Sensing method

Size

Model

Sensing distance (mm)

Giga mode

Standard mode

High-speed 

mode

Super-high-

speed mode

Through-beam

100

°

C

E32-T51R 2M

1,600

800

560

225

150

°

C

E32-T51 2M

2,800

1,500

1,000

400

200

°

C

E32-T81R-S 2M

1,000

550

360

140

350

°

C

E32-T61-S 2M

1,680

900

600

240

Reflective

100

°

C

E32-D51R 2M

670

280

190

80

150

°

C

E32-D51 2M

1,120

450

320

144

200

°

C

E32-D81R-S 2M

420

180

120

54

300

°

C

E32-A08H2 2M

10 to 20

---

E32-A09H2 2M

20 to 30 (center 25)

---

350

°

C

E32-D611-S 2M

420

180

120

54

E32-D61-S 2M

400

°

C

E32-D73-S 2M

280

120

80

36

Sensing method

Type

Sensing width

Model

Sensing distance (mm)

Giga mode

Standard mode

High-speed 

mode

Super-high-

speed mode

Through-beam

Area

11 mm

E32-T16PR 2M

3,100

1,700

1,120

440

E32-T16JR 2M

2,750

1,500

960

380

30 mm

E32-T16WR 2M

4,000 

*

2,600

1,700

680

Reflective

Array

11 mm

E32-D36P1 2M

700

300

200

90

Sensing method

Tube diameter

Feature

Model

Sensing distance (mm)

Giga mode

Standard mode

High-speed 

mode

Super-high-

speed mode

Tube-mounting

3.2, 6.4, 

or 9.5 dia.

Stable residual 

quantity detection

E32-A01 5M

Applicable tube: Transparent tube with a diameter of 3.2, 6.4, or 9.5 mm, 
Recommended wall thickness: 1 mm

8 to 10 dia.

Mounting at 

multiple levels

E32-L25T 2M

Applicable tube: Transparent tube with a diameter of 8 to 10 mm, 
Recommended wall thickness: 1 mm

No restrictions

Large tubes

E32-D36T 5M

Applicable tube: Transparent tube (no restrictions on diameter)

Liquid contact (heat-resistant 

up to 200

°

C)

---

---

E32-D82F1 4M

Liquid-contact type

Sensing method

Heat-resistant temperature

Model

Sensing distance (mm)

Giga mode

Standard mode

High-speed 

mode

Super-high-

speed mode

Through-beam

120

°

C

E32-T51V 1M

720

400

260

100

E32-T51V 1M+E39-F1V

2,000 

*

2,000 

*

1,360

520

200

°

C

E32-T84SV 1M

1,760

950

640

260

Sensing method

Application

Operating 

temperature

Model

Sensing distance (mm)

Giga mode

Standard mode

High-speed 

mode

Super-high-

speed mode

Limited-reflective

Glass presence detection

70

°

C

E32-L16-N 2M

0 to 15

0 to 12

Glass substrate alignment

E32-A08 2M

10 to 20

---

300

°

C

E32-A08H2 3M

70

°

C

E32-A12 2M

12 to 30

---

Glass substrate mapping

E32-A09 2M

15 to 38

---

300

°

C

E32-A09H2 2M

20 to 30 (center 25)

---

Wet processes: Cleaning, Resist 

developing and etching

60

°

C

E32-L11FP 5M

8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm),
19 to 31 mm from center of mounting hole A (Recommended sensing distance: 22 mm)

Wet process: 

Resist stripping

85

°

C

E32-L11FS 5M

8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm),
32 to 44 mm from center of mounting hole A (Recommended sensing distance: 35 mm)

Through-beam

Wafer mapping

70

°

C

E32-A03 2M

3,220

1,780

1,200

500

E32-A03-1 2M

E32-A04 2M

1,280

680

450

200

E32-T24SR 2M

4,000 

*

2,200

1,460

580

E32-T24S 2M

4,000 

*

2,600

1,740

700

Erstellt am 28.09.2020 um 20:20 Uhr | Alle Angaben ohne Gewähr, Irrtümer und Änderungen vorbehalten!

Seite 8 von 14

Summary of Contents for E3X-HD0

Page 1: ...ung Anwendung Easy Teach Typ Anschlusskabel Kabelsparender Steckverbinder M8 Steckverbinder Anschlussart NPN PNP Regelausgang 4 Modi 50 s 250 s 1 ms Ansprechzeit f r bis zu 10 Einheiten Schutz gegen g...

Page 2: ...Buttons are arranged in a straight line Sliding switches Pushbutton switches no sliding switches E3X HD Conventional Models Pleasing operation even with gloves on Hard to operate Finger gets caught O...

Page 3: ...ust be ordered separately as required End Plate Two End Plates are provided with the Sensor Communications Unit End Plates are not provided with the Fiber Amplifier Unit and must be ordered separately...

Page 4: ...reverse polarity protection and output short circuit protection Response time Super high speed mode SHS 3 NPN outputs Operate or reset 50 s PNP outputs Operate or reset 55 s High speed mode HS Operate...

Page 5: ...2M 450 250 150 60 1 5 dia E32 T22B 2M 680 400 220 90 3 dia E32 T12R 2M 2 000 1 000 700 280 Side view E32 T14LR 2M 750 450 260 100 Reflective 1 5 dia Top view E32 D22B 2M 140 60 40 16 1 5 dia 0 5 dia E...

Page 6: ...iew 10 E32 T17L 10M 20 000 1 20 000 1 20 000 1 8 000 15 E32 LT11 2M 4 000 2 4 000 2 2 700 1 080 E32 LT11R 2M 4 000 2 3 500 2 300 920 Side view 30 E32 T14 2M 4 000 2 4 000 2 4 000 2 1 800 Through beam...

Page 7: ...ance E32 A12 2M 12 to 30 Side view form Side view E32 L25L 2M 5 4 to 9 center 7 2 Glass substrate mapping 70 C Top view E32 A09 2M 15 to 38 Sensing method Type Sensing direction Model Sensing distance...

Page 8: ...ction E32 A01 5M Applicable tube Transparent tube with a diameter of 3 2 6 4 or 9 5 mm Recommended wall thickness 1 mm 8 to 10 dia Mounting at multiple levels E32 L25T 2M Applicable tube Transparent t...

Page 9: ...o 24 VDC OUT indicator orange Display M8 Connector Pin Arrangement Note Pin 2 is not used 1 2 4 3 1 4 3 Incident light No incident light Lit Not lit ON OFF Set Reset OUT indicator orange Output transi...

Page 10: ...esigned or rated for ensuring safety of persons either directly or indirectly Do not use it for such purposes Do not use the product with voltage in excess of the rated voltage Excess voltage may resu...

Page 11: ...rom separating due to vibration or other cause 4 Tighten the screw on the End Plates using a driver Maximum number of interconnected Maximum number of mutual interference prevention E3X HD series stan...

Page 12: ...3 5 16 Two M3 9 4 16 29 9 4 4 3 4 5 1 71 8 71 8 12 7 20 5 3 4 16 5 16 Optical communications Two 3 2 dia holes E39 L143 Mounting Bracket sold separately SUS304 33 5 33 5 10 3 4 3 16 5 Pre wired Amplif...

Page 13: ...0 4 5 5 65 104 8 104 8 max value with cover open 5 1 20 5 146 9 146 9 33 5 33 5 37 9 3 4 20 3 PFP N DIN Track sold separately 170 max value with cover open 49 2 71 8 71 8 16 Two M3 12 7 Fiber Attachme...

Page 14: ...Y Further in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted Suitability of Use Omron Companies shall not be responsible for confo...

Reviews: