background image

ATEG Automation GmbH

 

|

 Intzestraße 50 

|

 42859 Remscheid 

|

 Germany 

|

 Tel.: +49 (0)2191 / 591457-0 

|

 [email protected] 

|

 

www.ateg.de

Datenblatt

Lichtleiterverstärker E3X-HD

E3X-HD

E3X-HD

8

I/O Circuit Diagrams

NPN Output

PNP Output

Note:

Timing Charts for Timer Settings (T: Set Time)

Plug (Sensor I/O Connector)

Nomenclature

Models

Operation 

mode

Timing chart

L/D

indicators

Output circuit

E3X-HD11
E3X-HD6
E3X-HD14

Light-ON

Dark-ON

Incident light

N

o incident light

Lit

N

ot lit

O

N

OFF

Set

Reset

OUT indicator
(orange)
O

u

tp

u

t

transistor
Load
(e.g., relay)

(Bet

w

een 

b

l

u

e and

b

lack leads)

L

lit.

Photoelectric
Sensor main
circ

u

it

Load

Bro

w

n

Control o

u

tp

u

t

Black

Bl

u

e

12 to 
24 

V

DC

OUT indicator (orange)

Display

 M

8

 Connector Pin Arrangement

N

ote: Pin 2 is not 

u

sed.

1

2

4

3

1

4

3

Incident light

N

o incident light

Lit

N

ot lit

O

N

OFF

Set

Reset

OUT indicator
(orange)
O

u

tp

u

t

transistor
Load
(e.g., relay)

(Bet

w

een 

b

l

u

e and

b

lack leads)

lit.

D

Models

Operation 

mode

Timing chart

L/D

indicators

Output circuit

E3X-HD41
E3X-HD8
E3X-HD44

Light-ON

Dark-ON

Incident light

No incident light

Lit

Not lit

ON

OFF

Set

Reset

OUT indicator
(orange)
Output
transistor
Load
(e.g., relay)

(Between blue and

black leads)

L

lit.

Photoelectric
Sensor main
circ

u

it

Load

Control o

u

tp

u

t

Bro

w

n

Black

Bl

u

e

12 to 
24 

V

DC

OUT indicator (orange)

Display

 M

8

 Connector Pin Arrangement

N

ote: Pin 2 is not 

u

sed.

1

2

4

3

1

4

3

Incident light

No incident light

Lit

Not lit

ON

OFF

Set

Reset

OUT indicator
(orange)
Output
transistor
Load
(e.g., relay)

(Between blue and

black leads)

lit.

D

ON delay

OFF delay

One-shot

Incident light

N

o incident light

O

N

OFF

O

N

OFF

Light-O

N

Dark-O

N

T

T

T

T

Incident light

N

o incident light

O

N

OFF

O

N

OFF

Light-O

N

Dark-O

N

T

T

Incident light

N

o incident light

O

N

OFF

O

N

OFF

Light-O

N

Dark-O

N

Note:

Pin 2 is not used.

Wire color

Connection pin 

Application

Brown

1

Power supply (+V)

White

2

---

Blue

3

Power supply (0 V)

Black

4

Output

2

4

1

3

1
2
3
4

Bro

w

n

W

hite

Bl

u

e

Black

W

ire color

Terminal n

u

m

b

er

XS3F-M421-402-A
XS3F-M421-405-A

XS3F-M422-402-A
XS3F-M422-405-A

[L/D Indicator]

Indicates the setting stat

u

s:

Light-O

N

 (L) or Dark-O

N

 (D).

[DPC Indicator]

T

u

rns O

N

 

w

hen Dynamic Po

w

er Control is effecti

v

e.

[    L/D B

u

tton]

Use to s

w

itch 

b

et

w

een

Light-O

N

 (L) and Dark-O

N

 (D).

[OUT Indicator]

T

u

rns O

N

 

w

hen

the o

u

tp

u

t is O

N

.

[ST Indicator]

T

u

rns O

N

 

w

hen Smart T

u

ning

is in progress.

A

u

tomatically sets the emitter

po

w

er and set 

v

al

u

es.

Threshold Le

v

el

Green digital display

Incident Le

v

el

Red digital display

[

+−

UP/DO

WN

 B

u

tton]

Used to fine-t

u

ne the threshold

or change set 

v

al

u

es.

[    MODE B

u

tton]

Use to s

w

itch 

b

et

w

een Detection

Mode and Setting Mode.

[      TU

N

E B

u

tton]

Erstellt am 28.09.2020 um 20:20 Uhr | Alle Angaben ohne Gewähr, Irrtümer und Änderungen vorbehalten!

Seite 9 von 14

Summary of Contents for E3X-HD0

Page 1: ...ung Anwendung Easy Teach Typ Anschlusskabel Kabelsparender Steckverbinder M8 Steckverbinder Anschlussart NPN PNP Regelausgang 4 Modi 50 s 250 s 1 ms Ansprechzeit f r bis zu 10 Einheiten Schutz gegen g...

Page 2: ...Buttons are arranged in a straight line Sliding switches Pushbutton switches no sliding switches E3X HD Conventional Models Pleasing operation even with gloves on Hard to operate Finger gets caught O...

Page 3: ...ust be ordered separately as required End Plate Two End Plates are provided with the Sensor Communications Unit End Plates are not provided with the Fiber Amplifier Unit and must be ordered separately...

Page 4: ...reverse polarity protection and output short circuit protection Response time Super high speed mode SHS 3 NPN outputs Operate or reset 50 s PNP outputs Operate or reset 55 s High speed mode HS Operate...

Page 5: ...2M 450 250 150 60 1 5 dia E32 T22B 2M 680 400 220 90 3 dia E32 T12R 2M 2 000 1 000 700 280 Side view E32 T14LR 2M 750 450 260 100 Reflective 1 5 dia Top view E32 D22B 2M 140 60 40 16 1 5 dia 0 5 dia E...

Page 6: ...iew 10 E32 T17L 10M 20 000 1 20 000 1 20 000 1 8 000 15 E32 LT11 2M 4 000 2 4 000 2 2 700 1 080 E32 LT11R 2M 4 000 2 3 500 2 300 920 Side view 30 E32 T14 2M 4 000 2 4 000 2 4 000 2 1 800 Through beam...

Page 7: ...ance E32 A12 2M 12 to 30 Side view form Side view E32 L25L 2M 5 4 to 9 center 7 2 Glass substrate mapping 70 C Top view E32 A09 2M 15 to 38 Sensing method Type Sensing direction Model Sensing distance...

Page 8: ...ction E32 A01 5M Applicable tube Transparent tube with a diameter of 3 2 6 4 or 9 5 mm Recommended wall thickness 1 mm 8 to 10 dia Mounting at multiple levels E32 L25T 2M Applicable tube Transparent t...

Page 9: ...o 24 VDC OUT indicator orange Display M8 Connector Pin Arrangement Note Pin 2 is not used 1 2 4 3 1 4 3 Incident light No incident light Lit Not lit ON OFF Set Reset OUT indicator orange Output transi...

Page 10: ...esigned or rated for ensuring safety of persons either directly or indirectly Do not use it for such purposes Do not use the product with voltage in excess of the rated voltage Excess voltage may resu...

Page 11: ...rom separating due to vibration or other cause 4 Tighten the screw on the End Plates using a driver Maximum number of interconnected Maximum number of mutual interference prevention E3X HD series stan...

Page 12: ...3 5 16 Two M3 9 4 16 29 9 4 4 3 4 5 1 71 8 71 8 12 7 20 5 3 4 16 5 16 Optical communications Two 3 2 dia holes E39 L143 Mounting Bracket sold separately SUS304 33 5 33 5 10 3 4 3 16 5 Pre wired Amplif...

Page 13: ...0 4 5 5 65 104 8 104 8 max value with cover open 5 1 20 5 146 9 146 9 33 5 33 5 37 9 3 4 20 3 PFP N DIN Track sold separately 170 max value with cover open 49 2 71 8 71 8 16 Two M3 12 7 Fiber Attachme...

Page 14: ...Y Further in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted Suitability of Use Omron Companies shall not be responsible for confo...

Reviews: