background image

A-113

E3S-CL

E3S-C

L

Ordering Information

Rating/performance

Shape

Sensing/Setting range

Model

E3S-CL1

E3S-CL2

Sensing method

Distance-setting

Item

Model

E3S-CL1

E3S-CL2

Sensing

5 to 200 mm (White paper 200 x 200 mm) 
(Setting distance 200 mm)

5 to 500 mm (White paper 200 x 200 mm) 
(Setting distance 500 mm)

Setting range

40 to 200 mm (White paper 200 x 200 mm)

50 to 500 mm (White paper 200 x 200 mm)

Differential distance

2% max.

10% max.

Reflectivity characteristics 
(black/white error)

*1

*1. Sensing distance difference between standard white paper (reflectivity 90%) and standard black paper (reflectivity 5%)

2% max.

10% max.

Light source (wave length) Red LED (700 nm)

Infrared LED (860 nm)

Power supply voltage

10 to 30 VDC [ripple (p-p) 10% included]

Current consumption

35 mA max.

50 mA max.

Control output

Load supply voltage 30 VDC max., load current 100 mA max. (residual voltage NPN output: 1.2 V max., 
PNP output: 2.0 V max.) Open collector output type (NPN/PNP switch selectable) Light-ON/Dark-ON 
switch selectable

Protective circuits

Reverse polarity protection, output short-circuit protection, mutual interference prevention

Response time

Operation or reset: 1 ms max.

Operation or reset: 2 ms max.

Distance setting

6-turn endless adjuster (with indicator)

Ambient illuminance

Incandescent lamp: 5,000 lux max. Sunlight 10,000 lux max.

Ambient temperature

Operating/Storage: -25°C to 55°C (with no icing or condensation)

Ambient humidity

Operating/Storage: 35% to 85%RH (with no condensation)

Insulation resistance

20 M   min. at 500 VDC

Dielectric strength

1,000 VAC at 50/60 Hz for 1 minute

Vibration resistance

10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance

Destruction: 500 m/s

2

 for 3 times each in X, Y, and Z directions

Protective structure

IEC Standard IP67, NEMA 6P (limited to indoor use) 
*2

*2. NEMA (National Electrical Manufacturers Association) Standards

IEC Standard IP67, NEMA 6P (limited to indoor use)

Connection method

Pre-wired models (standard length: 2 m)

Weight (Packed state)

Approx. 170 g

Ma-
terial

Case

Zinc diecast

Operation panel 
cover

Polyethyl sulfon

Lens

Acrylics

Mounting Brackets

Stainless steel (SUS304)

Accessories

Mounting bracket, hexagon bolt M4 x 12 (with spring washer, flat washer), adjusting screwdriver, instruction 
manual

Red light

Infrared light

Setting range

40 to 200 mm

Max. setting

5

40mm

Detecting range

200mm

5

5 to 200 mm

Min. setting

5

50mm

Setting range

50 to 500 mm

Max. setting

Detecting range

500mm

5

5 to 500 mm

Min. setting

F502-EN2-04.book  Seite 113  Dienstag, 26. Juli 2005  5:48 17

Summary of Contents for E3S-CL

Page 1: ...ing Diffuse reflective Fea tures When the sensing object moves in direction A the center position of the reflected light moves in direction B This is received by the 2 split photodiode and the place w...

Page 2: ...Two division photodiode Receiver lens Light source LED Emitter lens By turning the distance setting ad juster worm gear the rotation of the gear moves the cam to change the incident angle of the whole...

Page 3: ...1 ms max Operation or reset 2 ms max Distance setting 6 turn endless adjuster with indicator Ambient illuminance Incandescent lamp 5 000 lux max Sunlight 10 000 lux max Ambient temperature Operating S...

Page 4: ...50 100 150 200 250 Spot diameter mm Distance mm 100 80 60 40 20 0 100 200 300 400 500 Sensing distance mm Material 200 150 100 50 0 White paper Black paper Sensitivity adjuster Max Sensitivity adjust...

Page 5: ...OFF Operate Reset Operation indicator orange Output transistor Load Relay Operation indicator Stability indicator PNP output transistor NPN output transistor NPN and PNP output selector Orange Green...

Page 6: ...hten the screws to the torque of 1 2 Nm max Sequence Detection state Position of dis tance setting ad juster State of setting dis tance indicator Indicator state Adjustment Steps 1 Point A Place a sen...

Page 7: ...Velocity No 3 2 02 Water in soluble coolant Class 2 No 5 Daphne Cut Not less than 10 to less than 50 Class 2 No 11 Yushiron Oil No 2ac Less than 10 Water soluble coolant Class W1 No 1 Yushiroken EC50T...

Page 8: ...terest of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into o...

Reviews: