52
Setting the sensor using the push buttons
Section 9-1
9-1
Setting the sensor using the push buttons
The sensor is set by means of three push buttons.
With these push buttons, the user navigates through the setting menus,
through which all necessary sensor settings can be made.
If no keys are pressed for 2 minutes during set-up, the sensor returns
automatically to run mode.
9-1-1
Display in the normal mode
Depending on the user set-up, the sensor's display shows the following in the
run mode:
• Status LED is turned off.
• Digital display:
The current distance from the sensor to the measured object in m.
• Bar display:
The current distance from the sensor to the measured object as a bar.
The display shows
0--0
if the sensor does not detect a measured
object.
The flashing display
----
appears in the event of a short-circuit on the
outputs.
The sensor resumes normal functioning when a short-circuit on the
outputs is eliminated.
The On-delay-setting
tr-1
or
tr-2
are only available if the switch-on/off delay
in the OPTIONS menu path is set to
on-1
.
Summary of Contents for E3NT-L
Page 1: ...OPERATION MANUAL Photoelectric Sensor Diffuse Reflective Sensor E3NT L Cat No E30E EN 01A...
Page 7: ...8 Abbreviations Section 1 7...
Page 8: ...9 SECTION 2 Safety Notes 2 1 Safety notes 10...
Page 21: ...22 Dimensions Section 3 3...
Page 45: ...46 Connection in line with EMC requirements Section 7 4...
Page 60: ...61 SECTION 10 Maintenance and Repair 10 1 Maintenance 62 10 2 Repair 62...
Page 62: ...63 SECTION 11 Accessories and Parts 11 1 Accessories and parts 64...
Page 64: ...65 SECTION 12 Appendix 12 1 Error messages 66 12 2 Factory default settings 67...