Mode
The diffuse reflective sensor can be operated in the following modes:
• Background suppression BGS (factory default)
Measured objects are detected as from the blind zone up to the user set
or teached switching point S
A
. Objects in the background, behind the user
set switching point, are ignored.
Figure 4 Background suppression
Accordingly for output 2 the switching point C (S
C
) is set.
• Foreground suppression FGS
Measured objects are detected as from the user set switching point S
A
up
to the maximum sensing distance. Objects in the foreground, between the
sensor’s blind zone and the user set switching point, are ignored.
Figure 5 Foreground suppression
Accordingly for output 2 the switching point C (S
C
) is set.
S
S
A
0
1
A
Output 1
S
S
A
0
1
A
Output 1
Summary of Contents for E3NT-L