background image

1

3

E3F2

Metal Models, radial type

Cable type

Connector type

Without potentiometer

E

3

F2-R2R

@

41-M

E

3

F2-R2R

@

41-M1

With potentiometer

E

3

F2-DS

3

0

@

41-M

E

3

F2-DS

3

0

@

41-M1-M

37

42.3

64.9

Light indic

a

tor

4.

8

 di

a

16.4 di

a

4 di

a

4

M1

8

x1 6g

6.9

optic

a

l

a

re

a

24

3.45

27.7

13.2

3

7

42.

3

Light indicator

4.8 dia

76

16.4 dia

M12x1.6g

4

M18x1.6g

65.5

6.9

24

27.7

3

.45

1

3

.2

optical
area

3

7

42.

3

49.

3

64.9

Light indicator

Sensitivity adjustor

4.8 dia

16.4 dia

4 dia

4

M18x1 6g

6.9

optical
area

24

3

.45

27.7

1

3

.2

3

7

42.

3

49.

3

Light indicator

Sensitivity adjustor

4.8 dia

16.4 dia

M12x1 6g

4

M18x1 6g

76

65.5

6.9

optical
area

24

1

3

.2

27.7

3

.45

Summary of Contents for E3F2 -

Page 1: ...l beam models High power LED to compensate for dirt and misalignment Performance and portfolio variety 1 SUS types see seperate datasheet 2 AC types see seperate datasheet 7 m 7 m 3 m Plastic Shape Se...

Page 2: ...ed wide beam 2 m E3F2 DS10B4 N 2M E3F2 DS10C4 N 2M E3F2 DS10B4 P1 E3F2 DS10C4 P1 0 3 m adjustable 2 m E3F2 DS30B4 2M E3F2 DS30C4 2M E3F2 DS30B4 P1 E3F2 DS30C4 P1 1 m adjustable 2 m E3F2 D1B4 2M E3F2 D...

Page 3: ...ical 1 1 Values in parentheses indicate the minimum required distance between the sensor and reflector Remark Order code Reflectors 3 m 100 mm axial types 2 m 100 mm radial types 60 x 40 mm E39 R1 4 m...

Page 4: ...ion resistance 10 to 55 Hz 1 5 mm double amplitude for 2 hrs each direction X Y Z Shock resistance Destruction 500 m s2 each direction X Y Z Degree of protection 1 1 The IP69k test according to DIN 40...

Page 5: ...5 3 0 0 50 100 50 100 Distance Y mm Distance X m 4 3 5 typical sensing distances E39 R1 2 4 m E39 R7 2 7 m E39 R8 3 1 m X Y Reflector 20 40 60 80 100 120 0 0 5 10 15 5 10 15 Distance Y mm Distance X m...

Page 6: ...Gain Reflectors E39 RS3 E39 R1S E39 R40 E39 R7 E39 R8 1 2 3 4 5 0 100 10 1 0 1 Excess gain Distance X m reflector E39 R1 reflector E39 R7 reflector E39 R8 20 40 60 80 100 120 0 100 10 1 0 1 Excess ga...

Page 7: ...g distance Background suppression Models E3F2 LS 0 2 4 6 0 50 100 150 Distance mm Spot diameter mm 20 00 10 00 0 00 10 00 20 00 40 30 20 10 0 10 20 30 40 Incline Angle Sensing Distence movement 20 00...

Page 8: ...ase Output indicator red Output transistor Load relay Light indicator Red Main circuit 1 2 3 4 1 2 3 4 Connector Pin Arrangement 10 to 30 VDC 100 mA max Load 0 V Mode selection Brown Black Blue Pink Z...

Page 9: ...30 VDC 100 mA max Load 0 V Mode selection Brown Black Blue Pink ZD VZ 36 V Stability indicator Green Only on models E3F2 R4C4 and E3F2 D1C4 Incident Interrupted ON OFF ON OFF Operate Release Output in...

Page 10: ...0 4 E3F2 D1 4 E3F2 R4 E3F2 DS30 4 P1 E3F2 D1 4 P1 E3F2 R4 P1 4 8 dia 37 42 3 64 9 M18x1 6g Light indicator 5 4 8 16 4 dia 6 2 22 24 4 dia optical area 5 4 8 M18x1 6g Light indicator 4 7 dia 42 3 37 M1...

Page 11: ...a 4 8 dia 4 dia 6 9 3 45 24 22 optical area 13 2 5 4 8 M18x1 6g Light indicator 4 7 dia 42 3 37 M12x1 6g 16 6 dia 73 62 6 9 optical area 24 13 2 22 3 45 37 42 3 49 3 M18x1 6g Light indicator Sensitivi...

Page 12: ...0 4 M1 M E3F2 R4 4 M1 M E3F2 D1 4 M1 M 4 8 dia 37 42 3 64 9 Light indicator 16 4 dia 4 dia 4 M18x1 6g 24 27 7 6 2 optical area 37 42 3 Light indicator 4 8 dia 76 16 4 dia M12x1 6g 4 M18x1 6g 24 27 7 6...

Page 13: ...dia 4 M18x1 6g 6 9 optical area 24 3 45 27 7 13 2 37 42 3 Light indicator 4 8 dia 76 16 4 dia M12x1 6g 4 M18x1 6g 65 5 6 9 24 27 7 3 45 13 2 optical area 37 42 3 49 3 64 9 Light indicator Sensitivity...

Page 14: ...39 F31 Material reflective surface acrylic Rear surface ABS 34 40 3 52 59 9 2 7 8 1 6 7 5 7 Two 3 5 dia 4 5 84 7 4 f for M3 for M3 9 100 100 92 92 for M3 8 7 84 5 84 5 77 77 80 4 R1 70 0 6 Adhesive ta...

Page 15: ...following locations 1 Locations subject to direct sunlight 2 Locations subject to condensation due to high humidity 3 Locations subject to corrosive gas 4 Locations where the Sensor may receive direc...

Page 16: ...isted may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document Nuclear energy contro...

Reviews: