F3W-D
3
3
Ratings and Specifications
*1. The F3W-D052
@
P Emitters are provided with the external picking indicator output line shown in the following table.
*2. The transmission indicator indicates bus transmission status.
*3. The following cable lengths are also available.
F3W-D052A (P): 2 m, 7 m
F3W-D052B : 1 m, 3.5 m
Sensing method
Through-beam
Item
Model
F3W-D052A (P)
*
1
F3W-D052B (P)
*
1
Sensing distance
3 m, switchable between LONG mode (1 to 3 m) and SHORT mode: (0.05 to 1 m), factory-set to SHORT mode.
Beam gap
25 mm
Number of beams
5
Sensing width
100 mm
Standard sensing object
Opaque, 35 mm dia. min.
Light source
(emission wavelength)
Infrared LED (860 nm)
Power supply voltage
12 to 24 VDC±10% (ripple (p-p): 10% max.)
Power consumption
Emitter: 0.6 W max., Receiver: 0.7 W max.
Control output
NPN open collector with 100 mA max. at 30 VDC
NPN open collector output type
Dark-ON or Light-ON (selectable)
Picking instruction
indicator input
Open collector with relay or transistor input
Indicator ON: Input voltage of 0 to 2 V
Indicator OFF: Open (with leakage current of 0.1 mA max.)
Protection circuits
Reverse-connection protection, output short protection, and mutual interference prevention function
(set with frequency switch)
Response time
Operate/Reset: 10 ms max.
Indicators
Receiver
Operation indicator (orange), stability indicator (green), and 6 picking indicators (orange),
UNI-WIRE Direct Connection Models: Transmission indicator (orange)
*
2
Emitter
Power indicator (green), different frequency indicator (green), and 6 picking indicators (orange),
UNI-WIRE Direct Connection Models: Transmission indicator (orange)
*
2
Ambient temperature
Operating:
−
10
°
to 55
°
C, Storage:
−
25
°
to 70
°
C (with no icing or condensation)
Ambient humidity
35% to 85% (with no condensation)
Insulation resistance
20 M
Ω
min. (at 500 VDC)
Dielectric strength
1,000 VAC 50/60 Hz for 1 min
Vibration resistance
(destruction)
10 to 50 Hz, 1.5-mm double-amplitude for 2 hours each in X, Y and Z directions
Shock resistance
(destruction)
500 m/s
2
, 3 times each in X, Y and Z directions
Degree of protection
IEC60529: IP62 (with the operation cover closed)
Connection method
Pre-wired
Standard cable length: 5 m
*
3
Pre-wired connector
(M12 5-pin connector)
Standard cable length: 2 m
*
3
Weight (packed state)
Approx. 360 g
Approx. 230 g
Materials
Case,
indicator
windows
ABS resin
Lens
Acrylic resin
Opera-
tion
cover
Nylon (PA6)
Accessories
Instruction manual
Item
F3W-D052AP, F3W-D052BP
Connection method
Pre-wired (standard cable length: 300 mm)
Electrical specifications
Output current: 50 mA max.
Output voltage: Fixed at Sensor power supply voltage