![background image](http://html1.mh-extra.com/html/omron/e3c-ld11/e3c-ld11_manual_740997022.webp)
10
E3NC
* When the number of connected units is 11 or more, the ambient temperature is less than 50°C.
Type
Standard models
Model for Sensor
Communications Unit
NPN output
E3NC-SA21
E3NC-SA7
E3NC-SA24
E3NC-SA0
PNP output
E3NC-SA51
E3NC-SA9
E3NC-SA54
Item
Connecting
method
Pre-wired
Wire-saving Connector
M8 Connector
Connector for Sensor
Communications Unit
Ambient temperature range
*
Operating:
Groups of 1 or 2 Amplifier Units:
−
25 to 55
°
C,
Groups of 3 to 10 Amplifier Units:
−
25 to 50
°
C,
Groups of 11 to 16 Amplifier Units:
−
25 to 45
°
C,
Groups of 17 to 30 Amplifier Units:
−
25 to 40
°
C
Storage:
−
30 to 70°C (with no icing or condensation)
Operating:
Groups of 1 or 2 Amplifier
Units: 0 to 55
°
C,
Groups of 3 to 10 Amplifier
Units: 0 to 50
°
C,
Groups of 11 to 16 Amplifier
Units: 0 to 45
°
C,
Groups of 17 to 30 Amplifier
Units: 0 to 40
°
C
Storage:
−
30 to 70°C (with
no icing or condensation)
Ambient humidity range
Operating and storage: 35% to 85% (with no condensation)
Insulation resistance
20 M
Ω
(at 500 VDC)
Altitude
2,000 m max.
Installation environment
Pollution degree 3 (as per IEC 60947-1)
Dielectric strength
1,000 VAC at 50/60 Hz for 1 min
Vibration resistance (destruction)
10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance (destruction)
500 m/s
2
for 3 times each in X, Y, and Z directions
150 m/s
2
for 3 times each in X,
Y, and Z directions
Weight (packed state/Amplifier Unit only)
Approx. 115 g/approx. 75 g
Approx. 60 g/approx. 20 g
Approx. 65 g/approx. 25 g
Materials
Case
Polycarbonate (PC)
Cover
Polycarbonate (PC)
Cable
Vinyl chloride (PVC)
Accessories
Instruction Manual