Precautions

Power supply

Do not impose an excessive voltage on the E2Q2, otherwise

it may explode or burn.

Do not connect an AC power supply to any DC model. If AC

power (100 VAC or more) is supplied to the sensor, it may ex-

plode or burn.

Do not connect the AC types without load to the power supply.

The sensor will be damaged.

Be sure to abide by the following precautions for the safe op-

eration of the Sensor.

Wiring

Power Supply Voltage and Output Load Power Supply Volt-
age

Make sure that the power supply to the Sensor is within the

rated voltage range. If a voltage exceeding the rated voltage

range is supplied to the Sensor, it may explode or burn.

Load Short-circuiting

Do not short-circuit the load, otherwise the Sensor may be

damaged.

Connection without Load

Do not connect the power supply to the Sensor with no load

connected, otherwise the internal elements may explode or

burn.

Operating Environment

Do not use the Sensor in locations with explosive or flamma-

ble gas.

Design

Effects of Surrounding Metal

Provide a minimum distance between the Sensor and the sur-

rounding metal as shown in the table below.

Mutual Interference

If more than one Sensor is located in parallel, ensure to main-

tain enough space between adjacent Sensors to suppress

mutual interference as provided in the following diagram.

Power Reset Time

The Sensor is ready to operate within 300 ms after the Sensor

is turned ON. If the load and Sensor are connected to inde-

pendent power supplies respectively, be sure to turn ON the

Sensor before supplying power to the load.

Power OFF

The Proximity Sensor may output a pulse signal when it is

turned OFF. Therefore, it is recommended that the load be

turned OFF before turning OFF the Proximity Sensor.

Power Supply Transformer

When using a DC power supply, make sure that the DC power

supply has an insulated transformer. Do not use a DC power

supply with an auto-transformer.

Sensing Object

The sensing distance of the Proximity Sensor vary with the

metal coating on sensing objects.

!

 Caution

Correct Use

Effects of Surrounding Metal  (Unit: mm)

Model

Length

A

B

C

E2Q2-N15

# #

-

# #

E2Q2-N20

##

-

#

45

0

0

E2Q2-N30M

# #

-

#

90

250

30

E2Q2-N40M

# #

-

#

120

300

40

Mutual Interference  (Unit: mm)

Model

Length

A

E2Q2-N15

# #

-

# #

E2Q2-N20

##

-

#

40

E2Q2-N30M

# #

-

#

120

E2Q2-N40M

# #

-

#

150

A

B

C

A

Side-by-side

F502-EN2-04.book  Seite 75  Dienstag, 26. Juli 2005  5:48 17

Summary of Contents for E2Q2

Page 1: ...ield Immune DC type 100mT Weld Field Immune AC type 100mT Sensing distance Connection Active face Output NO NO NC 20 mm shielded Terminals Changeable NPN E2Q2 N20E1 H E2Q2 N20E3 PNP E2Q2 N20F1 H E2Q2 N20F3 30 mm non shielded NPN E2Q2 N30ME3 PNP E2Q2 N30MF3 40 mm non shielded NPN E2Q2 N40ME3 PNP E2Q2 N40MF3 Sensing distance Connection Active face Output NO NO or NC 15 mm shielded Terminals Changeab...

Page 2: ... NPN NO NC E2Q2 N F1 PNP NO E2Q2 N F3 PNP NO NC Load 200 mA max On stage voltage drop 3 VDC max at 200 mA load current Circuit protection Reverse polarity output short circuit Alternating magnetic field 100 mT Indicator Operating indicator yellow LED operating voltage green LED Ambient temperature Operating 25 to 70 C Ambient humidity 35 to 95 RH Influence of temperature 10 max of Sn at 23 in temp...

Page 3: ...500 mA load current Circuit protection Alternating magnetic field 100 mT Indicator Operating indicator yellow LED operating voltage green LED Ambient temperature Operating 25 to 70 C Ambient humidity 35 to 95 RH Influence of temperature 10 max of Sn at 23 in temperature range of 25 to 70 C Dielectric strength 1 500 VAC 2500 VAC E2Q2 H 50 60 Hz for 1 min between current carry parts and case Electro...

Page 4: ...tput NO ON OFF Control output NC White NC Load Load Brown Black Blue V 0 V Proximity Sensor main circuits 4 7kΩ 4 7kΩ Operation Indicator yellow NO Sensing object 100 0 Rated sensing distance Sensing zone Non sensing zone Proximity Sensor ON OFF ON OFF Yellow indicator Control output Load Brown Black Blue V 0 V Proximity Sensor main circuits 4 7kΩ Operation Indicator yellow sensing Sensing object ...

Page 5: ...D 73 E2Q2 E2Q2 Dimensions Unit mm E2Q2 H type E2Q2 U and 51 type M20x1 5 NPT ...

Page 6: ... the supply voltage is 100 V minimum OR parallel connec tion In principle more than two Proximity Sensors cannot be connected in parallel Provided that Proximity Sensor A does not operate with Proximity Sen sor B simultaneously and there is no need to keep the load operating continuously the Proximity Sensors can be connected in parallel In this case however due to the total leakage current of the...

Page 7: ... minimum distance between the Sensor and the sur rounding metal as shown in the table below Mutual Interference If more than one Sensor is located in parallel ensure to main tain enough space between adjacent Sensors to suppress mutual interference as provided in the following diagram Power Reset Time The Sensor is ready to operate within 300 ms after the Sensor is turned ON If the load and Sensor...

Page 8: ...sassemble or repair the Sensor Environment Water Resistivity Do not use the Proximity Sensor underwater outdoors or in the rain Operating Environment Be sure to use the Proximity Sensor within its operating ambi ent temperature range and do not use the Proximity Sensor outdoors so that its reliability and life expectancy can be main tained Although the Proximity Sensor is water resistive a cover t...

Reviews: