![background image](http://html.mh-extra.com/html/omron/e2q2/e2q2_datasheet_740928003.webp)
D-71
E2Q2
E2Q
2
AC type
shielded
non-shielded
Item
Model
E2Q2-N15 Y4-51
weld-immune type
E2Q2-N15
##
-
#
E2Q2-N30
##
-
#
Sensing distance Sn
15 mm ± 10%
30 mm ± 10%
Standard target size, L x W x H, Fe 37
45 x 45 x 1 mm
90 x 90 x 1 mm
Setting distance
0 to 12,15 mm
0 to 24,3 mm
Switching frequency
20 Hz
Sensing object
Ferrous metals
Differential travel
15% max. of sensing distance Sn
Operating voltage
20 to 253 VAC
Off-state current
2,5 mA max.
1,9 mA max.
Control output
Type
AC - NO or NC
Load
500 mA max.
10 mA min.
8 mA min.
On-stage voltage drop 12 VAC max. (at 500 mA load current)
Circuit protection
---
Alternating magnetic field
100 mT
---
Indicator
Operating indicator (yellow LED), operating voltage (green LED)
Ambient temperature
Operating: -25° to 70°C
Ambient humidity
35 to 95% RH
Influence of temperature
± 10% max. of Sn at 23° in temperature range of -25° to 70°C
Dielectric strength
1.500 VAC / 2500 VAC (E2Q2-...-H), 50/60 Hz for 1 min. between current carry parts and
case
Electromagnetic compatibility EMC
EN 60947-5-2
Vibration resistance
10 to 55 Hz, 1 mm amplitude according IEC 60068-2-6
Shock resistance
Approx. 30 G for 11 ms according to IEC 60068-2-27
Protection degree
IEC 60529
IP 67
Connection
Terminals
Up to 2,5 mm²
Material
Case
Terminal base
PBT
Al
PBT (...-H type)
Sensing face
PBT
Approvals
CERTIFIED
LISTED