background image

D-177

E2EQ

E2EQ

Dimensions (Unit: mm)

 Pre-wired Models

Extended-distance type

Standard

E2EQ-X4X1

E2EQ-X8X1

E2EQ-X15X1

E2EQ-X3D1

E2EQ-X7D1

E2EQ-X10D1

21 dia.

4

17

33

10

2

9

38

M12 x 1

Indicator *2

Two, clamping nuts 

Toothed washer

*1

*1: Vinyl-insulated round cable (flame-resistant), 4 dia.
2/3 conductors (conducting cross-sectional area: 0.3 mm

2

/insulator 

diameter: 1.3 mm
Standard length: 2m
Cable extension (through a single metal conduit): 200m max.
*2: Operation indicator (red) and setting indicator (green).

*1: Vinyl-insulated round cable (flame-resistant), 6 dia.
2/3 conductors (conducting cross-sectional area: 0.5 mm

2

/insulator 

diameter: 1.9 mm
Standard length: 2m
Cable extension (through a single metal conduit): 200m max.
*2: Operation indicator (red) and setting indicator (green).

29 dia.

4

24

38

10

2

12

43

M18 x 1

Indicator *2

Two, clamping nuts 

Toothed washer

*1

*1: Vinyl-insulated round cable (flame-resistant), 6 dia.
2/3 conductors (conducting cross-sectional area: 0.5 mm

2

/insulator 

diameter: 1.9 mm
Standard length: 2m
Cable extension (through a single metal conduit): 200m max.
*2: Operation indicator (red) and setting indicator (green).

42 dia.

5

36

43

10

3

12

48

M30 x 1.5

Indicator *2

Two, clamping nuts 

Toothed washer

*1

*1: Vinyl-insulated round cable (flame-resistant), 6 dia., 2 conductors 
(conducting cross-sectional area: 0.5 mm

2

/insulator diameter: 1.9 mm

Standard length: 2m
Cable extension (through a single metal conduit): 200m max.
*2: Operation indicator (red) and setting indicator (green).

5

4

M12 x 1

Two, toothed washer

Indicator *2 *1

Two, clamping nuts (Teflon coating)

17

21 dia.

24

27.6

38

*1: Vinyl-insulated round cable (flame-resistant), 6 dia., 2 conductors 
(conducting cross-sectional area: 0.5 mm

2

/insulator diameter: 1.9 mm

Standard length: 2m
Cable extension (through a single metal conduit): 200m max.
*2: Operation indicator (red) and setting indicator (green).

24

29 dia.

6

29

32

47

4

M18 x 1

Two, toothed washer

Indicator *2

*1

Two, clamping nuts (Teflon coating)

*1: Vinyl-insulated round cable (flame-resistant), 6 dia., 2 conductors 
(conducting cross-sectional area: 0.5 mm

2

/insulator diameter: 1.9 mm

Standard length: 2m
Cable extension (through a single metal conduit): 200m max.
*2: Operation indicator (red) and setting indicator (green).

10

5

M30 x 1.5

Two, toothed washer

Indicator *2

*1

Two, clamping nuts (Teflon coating)

42 dia.

36

38

42

56

F502-EN2-04.book  Seite 177  Dienstag, 26. Juli 2005  5:48 17

Summary of Contents for E2EQ

Page 1: ...ng status Model M12 DC 2 wire NO E2EQ X4X1 M18 E2EQ X8X1 M30 E2EQ X15X1 Shape Sensing distance Output specifications Operating status Model M12 DC 2 wire NO E2EQ X3D1 M18 E2EQ X7D1 M30 E2EQ X10D1 Shap...

Page 2: ...g capacity 3 to 100 mA Residual voltage 3 3 Since residual voltage is 5 V use it after checking interface requirements with the connection devices 5 0 V max under load current of 100 mA with cable len...

Page 3: ...ture range of 25 C and 70 C Voltage influence 2 5 max of Sensing distance within rated voltage range 15 Shock resistance Destruction 1 000 m s2 for 10 times each in X Y and Z directions Connection met...

Page 4: ...h of sensing object d mm Sensing distance X mm 20 16 12 8 4 0 10 30 20 40 50 60 70 80 Stainless steel SUS304 Mild steel Brass Aluminum Copper d t 1mm X 4 0 3 5 3 0 2 5 2 0 1 5 1 0 0 5 0 5 10 15 20 25...

Page 5: ...nnected to either the V or the 0 V line 2 Since there is no polarity there is no need to pay attention to the brown or blue polarity Brown Blue Main circuit V 0V Load 3 4 Wiring Note Terminals B and C...

Page 6: ...s In the previous examples the nut is on the sensor head side part B and hence the tightening torque for part B applies If this nut is in part A the tightening torque for part A applies instead 2 The...

Page 7: ...uit 200m max 2 Operation indicator red and setting indicator green 42 dia 5 36 43 10 3 12 48 M30 x 1 5 Indicator 2 Two clamping nuts Toothed washer 1 1 Vinyl insulated round cable flame resistant 6 di...

Page 8: ...10 5 43 48 12 36 Indicator 2 Two clamping nuts Toothed washer M30 x 1 5 M12 x 1 1 1 Vinyl insulated round cable flame resistant 6 dia Standard length 300 mm 2 Operation indicator red and setting indi...