D-175

E2EQ

E2EQ

Output Circuit Diagram

Extended-distance type

Standard

Connecting Plug-in models

Model

Ope-

rating 

status

Timing chart

Output circuit

E2EQ-X4X1
E2EQ-X8X1
E2EQ-X15X1
E2EQ-X4X1-M1J
E2EQ-X8X1-M1J
E2EQ-X15X1-M1J

NO

Model

Ope-

rating 

status

Timing chart

Output circuit

E2EQ-X3D1
E2EQ-X7D1
E2EQ-X10D1
E2EQ-X3D1-M1GJ
E2EQ-X7D1-M1GJ
E2EQ-X10D1-M1GJ

NO

Model

E2EQ-X

#

X1-M1J

E2EQ-X

#

D1-M1GJ

Connection

Sensing 
object

(%)

100

80(TYP)

Rated 

sensing 
distance

Stable sensing zone

Non-sensing zone

Unstable 
sensing zone

Setting point

Lit

Not lit

Lit

Not lit

ON

OFF

Green 
indicator

Red 
indicator

Control 
output

0

Note:
1. The load can be connected to either the +V or the 0-V line.
2. Since there is no polarity, there is no need to pay attention 
to the brown or blue polarity.

Brown

Blue

Main 
circuit

+V

0V

Load

3

4

Wiring

Note:
Terminals 

B

 and 

C

 are not used.

3

1

2

4

Sensing 
object

(%)

100

0

80(TYP)

Stable sensing zone

Non-sensing zone

Unstable 
sensing zone

Setting point

Main circuit

Lit

Not lit

Lit

Not lit

ON

OFF

Green indicator

Red indicator

Control output

Rated 

sensing 
distance

Wiring

Note:
Terminals 

B

 and 

C

 are not used.

Note:
The Load can be connected to either the 
+V or the 0-V line.

Load

Brown

Blue

Main 
circuit

+V

0V

1

4

A

D

B

C

Main circuit

1

2

3

4

1

2

3

4

Brown

Black (-)

Blue (+)

Connector relay type
E2EQ-X

#

X1-M1J

Sensor I/O Connectors
XS2F-D42

#

-

#

C0-A

not connected

Main circuit

1

2

3

4

1

2

3

4

Brown (+)

Blue (-)

Connector relay type
E2EQ-X

#

D1-M1GJ

Sensor I/O Connectors
XS2F-D42

#

-

#

A0-A

F502-EN2-04.book  Seite 175  Dienstag, 26. Juli 2005  5:48 17

Summary of Contents for E2EQ

Page 1: ...ng status Model M12 DC 2 wire NO E2EQ X4X1 M18 E2EQ X8X1 M30 E2EQ X15X1 Shape Sensing distance Output specifications Operating status Model M12 DC 2 wire NO E2EQ X3D1 M18 E2EQ X7D1 M30 E2EQ X10D1 Shap...

Page 2: ...g capacity 3 to 100 mA Residual voltage 3 3 Since residual voltage is 5 V use it after checking interface requirements with the connection devices 5 0 V max under load current of 100 mA with cable len...

Page 3: ...ture range of 25 C and 70 C Voltage influence 2 5 max of Sensing distance within rated voltage range 15 Shock resistance Destruction 1 000 m s2 for 10 times each in X Y and Z directions Connection met...

Page 4: ...h of sensing object d mm Sensing distance X mm 20 16 12 8 4 0 10 30 20 40 50 60 70 80 Stainless steel SUS304 Mild steel Brass Aluminum Copper d t 1mm X 4 0 3 5 3 0 2 5 2 0 1 5 1 0 0 5 0 5 10 15 20 25...

Page 5: ...nnected to either the V or the 0 V line 2 Since there is no polarity there is no need to pay attention to the brown or blue polarity Brown Blue Main circuit V 0V Load 3 4 Wiring Note Terminals B and C...

Page 6: ...s In the previous examples the nut is on the sensor head side part B and hence the tightening torque for part B applies If this nut is in part A the tightening torque for part A applies instead 2 The...

Page 7: ...uit 200m max 2 Operation indicator red and setting indicator green 42 dia 5 36 43 10 3 12 48 M30 x 1 5 Indicator 2 Two clamping nuts Toothed washer 1 1 Vinyl insulated round cable flame resistant 6 di...

Page 8: ...10 5 43 48 12 36 Indicator 2 Two clamping nuts Toothed washer M30 x 1 5 M12 x 1 1 1 Vinyl insulated round cable flame resistant 6 dia Standard length 300 mm 2 Operation indicator red and setting indi...

Reviews: