background image

Proximity Sensors Technical Guide

General Precautions

For precautions on individual products, refer to the 

Safety Precautions

 in individual product information.

These products cannot be used in safety devices for 
presses or other safety devices used to protect human 
life.
These products are designed for use in applications for 
sensing workpieces and workers that do not affect safety.

To ensure safety, always observe the following precautions.

Wiring Considerations

Operating Environment

Do not use the Sensor in an environment where there are explosive or combustible gases.

WARNING

Precautions for Safe Use

Item

Typical examples

Power Supply Voltage

Do not use a voltage that exceeds the operat-
ing voltage range. Applying a voltage that is 
higher than the operating voltage range, or us-
ing an AC power supply (100 VAC or higher) 
for a Sensor that requires a DC power supply 
may cause explosion or burning.

DC 3-Wire NPN Output Sensors

DC 2-Wire Sensors

Load short-circuiting

Do not short-circuit the load. Explosion or 
burning may result.

The load short-circuit protection function op-
erates when the power supply is connected 
with the correct polarity and the power is 
within the rated voltage range.

DC 3-Wire NPN Output Sensors

DC 2-Wire Sensors

Even with the load short-circuit protection 
function, protection will not be provided when 
a load short circuit occurs if the power supply 
polarity is not correct.

Incorrect Wiring

Be sure that the power supply polarity and oth-
er wiring is correct. Incorrect wiring may cause 
explosion or burning.

DC 3-Wire NPN Output Sensors

Connection without a Load

If the power supply is connected directly with-
out a load, the internal elements may explode 
or burn. Be sure to insert a load when connect-
ing the power supply.

DC 2-Wire Sensors

Even with the load short-circuit protection 
function, protection will not be provided if 
both the power supply polarity is incorrect 
and no load is connected.

AC 2-Wire Sensors

Load

Sensor

Brown

Blue

Black

Load

Sensor

Brown

Blue

+

(Load short  
circuit)

Load

Sensor

Brown

Blue

Black

(Load short circuit)

Load

Sensor

Brown

Blue


+

+

+

Load

Load

Sensor

Brown

Black

Blue

Sensor

Brown

Blue

Black


+

Sensor

Brown

Blue

Sensor

Brown

Blue

http://www.ia.omron.com/

C-1

(c)Copyright OMRON Corporation 2007   All Rights Reserved. 

Summary of Contents for E2EC -

Page 1: ...e also available The model numbers are E2EC 5 example E2EC CR8D15 DC 3 Wire Models Models with different frequencies are also available The model numbers are E2EC 5 example E2EC CR5D15 Accessories Ord...

Page 2: ...proaching D1 Models NO D2 Models NC Refer to the timing charts under I O Circuit Diagrams on page 5 for details NO Refer to the timing charts under I O Circuit Diagrams on page 5 for details Protectio...

Page 3: ...nce X mm Distance Y mm Sensing Head Y X 4 3 2 1 0 3 1 2 0 1 2 3 4 4 Distance X mm Distance Y mm Sensing Head Y X 6 5 4 3 2 1 0 4 2 0 2 4 Distance Y mm Distance X mm Sensing Head Y X 0 6 0 5 0 4 0 3 0...

Page 4: ...er Brass Distance X mm Side length of sensing object d mm Stainless steel SUS304 Iron X 5 4 3 2 1 0 5 35 30 25 15 20 10 d d t 1 mm Distance X mm Side length of sensing object d mm Brass Copper Stainle...

Page 5: ...tor green Operation indicator red Control output 0 V V Load Brown Blue Prox imity Sensor main circuit Note The load can be connected to either the V or 0 V side 0 100 Sensing object Rated sensing dist...

Page 6: ...Permissible Tightening Range and Torque x The tightening torque applied to the E2EC X4D Threaded Cylindrical Models must be 12 N m max Amplifier Mounting Bracket for DC 2 Wire Models Mounting 1 Insert...

Page 7: ...8 25 5 35 5 18 8 dia 5 4 24 2 1 10 3 6 1 6 dia shielded robotics cable Standard length 400 mm 2 9 dia vinyl insulated round robotics cable with 2 conductors Conductor cross section 0 15 mm2 Insulator...

Page 8: ...round cable with 3 conductors Conductor cross section 0 2 mm2 Insulator diameter 1 2 mm Standard length 2 m 2 The cable can be extended up to 50 m separate metal conduit 3 2 5 dia shielded cable Stan...

Page 9: ...t The load short circuit protection function op erates when the power supply is connected with the correct polarity and the power is within the rated voltage range DC 3 Wire NPN Output Sensors DC 2 Wi...

Page 10: ...stive load Non contact control system Inductive load Relay solenoid etc Steady state current inrush current Operating reset voltage current Lamp load Steady state current inrush current Open close fre...

Page 11: ...or is affected by magnetism or static capacitance from an adjacent Sensor and the output is unstable One means of avoiding interference when mounting Proximity Sensors close together is to alternate S...

Page 12: ...o do not use a Proximity Sensor to turn the power supply ON and OFF for electronic devices that use DC half wave rectification In such a case use a relay to turn the power supply ON and OFF and check...

Page 13: ...sert the front of the Sensor into the special Mounting Bracket included or DIN Track 2 Press the rear of the Sensor into the special Mounting Bracket or DIN Track When mounting the side of the Sensor...

Page 14: ...in series with an AND circuit the limit is three Sensors Be careful of the VS value in the diagram at left OR parallel connection In general it is not possible to use two or more Proximity Sensors in...

Page 15: ...M1J T is 5 V Model Type of connection Connection Description DC 3 wire AND series connection Keep the number of connected Sensors N within the range of the following equation iL N 1 i Upper limit of...

Page 16: ...or hot concentrated sulfuric acid Maintenance and inspection Periodic Inspection To ensure long term stable operation of the Proximity Sensor inspect for the following on a regular basis Conduct these...

Page 17: ...may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog Nuclear energy control syst...