E2EC
Dimensions
(Unit: mm)
Main Units
6
10
8
25.5
35
12
3
±
0.1
dia.
5.4
24.2
*1
10.3
6
1.6-dia shielded robotics cable,
Standard length: 400 mm
2.9-dia. vinyl-insulated round robotics cable
with 2 conductors (Conductor cross section:
0.15 mm
2
, Insulator diameter: 1 mm),
Standard length: 2 m
Indicators *2
Two, 3.2-dia. mounting holes
Mounting Bracket
*1. The cable can be extended up to 200 m
(separate metal conduit).
*2. D1 Models: Operation indicator (red),
Setting indicator (green)
D2 Models: Operation indicator (red)
With Mounting Bracket Attached
E2EC-CR8D
@
6
10
8
25.5
35
18
5.4 dia.
5.4
24.2
6
*1
10.3
1.6-dia shielded robotics cable,
Standard length: 400 mm
2.9-dia. vinyl-insulated round robotics cable
with 2 conductors (Conductor cross section:
0.15 mm
2
, Insulator diameter: 1 mm),
Standard length: 2 m
Indicators *2
Two, 3.2-dia. mounting holes
Mounting Bracket
*1. The cable can be extended up to 200 m
(separate metal conduit).
*2. D1 Models: Operation indicator (red),
Setting indicator (green)
D2 Models: Operation indicator (red)
E2EC-C1R5D
@
With Mounting Bracket Attached
E2EC-C3D
@
6
10
8
25.5
35
5
18
8 dia.
5.4
24.2
*1
10.3
6
1.6-dia shielded robotics cable, Standard
length: 400 mm
2.9-dia. vinyl-insulated round robotics cable with 2
conductors (Conductor cross section: 0.15 mm
2
,
Insulator diameter: 1 mm), Standard length: 2 m
Indicators *2
Two, 3.2-dia. mounting holes
Mounting Bracket
*1. The cable can be extended up to 200 m
(separate metal conduit).
*2. D1 Models: Operation indicator (red),
Setting indicator (green)
D2 Models: Operation indicator (red)
With Mounting Bracket Attached
E2EC-X4D
@
10
8
25.5
4
M12
×
1
18
*1
5.6
6
6
10.3
5.4
24.2
35
1.6-dia shielded robotics cable,
Standard length: 400 mm
Two clamping nuts
17 mm across
Two toothed
washers
2.9-dia. vinyl-insulated round robotics cable
with 2 conductors (Conductor cross section:
0.15 mm
2
, Insulator diameter: 1 mm),
Standard length: 2 m
Indicators *2
Two, 3.2-dia. mounting holes
Mounting Bracket
*1. The cable can be extended up to 200 m
(separate metal conduit).
*2. D1 Models: Operation indicator (red),
Setting indicator (green)
D2 Models: Operation indicator (red)
With Mounting Bracket Attached
Model
F (mm)
E2EC-CR8D
@
3.3
dia.
E2EC-C1R5D
@
5.7
dia.
E2EC-C3D
@
8.5
dia.
E2EC-X4D
@
12.5
dia.
+0.3
0
+0.3
0
+0.5
0
+0.5
0
Mounting Hole Dimensions
F
http://www.ia.omron.com/