DRT2-ID16/OD16

DRT2-ID16/OD16

Specifications

General Specifications

Input Specifications

Output Specifications

Item

Specification

Network power voltage

11 to 25 VDC (supplied from the communications connector)

I/O power supply voltage

20.4 to 26.4 VDC (24 VDC -15% to +10%)

Noise immunity

Conforms to IEC61000-4-4: 2 kV (power lines)

Vibration resistance

10 to 50 Hz, 0.7-mm double amplitude

Shock resistance

200 m/S

2

Dielectric strength

500 VAC (between isolated circuits)

Insulation resistance

20 M

Ω 

min. (between isolated circuits)

Ambient operating temperature

-10 to +55

°

C

Ambient operating humidity

35% to 85%

Ambient atmosphere

No corrosive gases

Ambient storage temperature

-20 to +65

°

C

Mounting method

35-mm DIN track mounting

Mounting strength

50 N (in directions other than the DIN track direction), 10 N (in the DIN track direction)

Screw tightening torque

M3 (power supply, I/O terminals): 0.3 to 0.5 N

m

Item

Specification

Model number

DRT2-ID16

DRT2-ID16-1

Internal I/O common processing

NPN

PNP

Number of I/O points

16 inputs

ON voltage

15 VDC min. (between each input terminal 
and V)

15 VDC min. (between each input terminal 
and G)

OFF voltage

5 VDC min. (between each input terminal 
and V)

5 VDC min. (between each input terminal 
and G)

OFF current

1.0 mA max. per point (at 24 VDC)

Input current

6.0 mA max. per point at 24 VDC; 3.0 mA max. per point at 17 VDC

ON delay time

1.5 ms max.

OFF delay time

1.5 ms max.

Number of points per common

16 points per common

Item

Specification

Model number

DRT2-OD16

DRT2-OD16-1

Internal I/O common processing

NPN

PNP

Number of I/O points

16 outputs

Rated output current

0.5 A per point, 4.0 A per common

Residual voltage

1.2 V max. (0.5 A between each output termi-
nal and G)

1.2 V max. (0.5 A between each output termi-
nal and V)

Leakage current

0.1 mA max.

ON delay time

0.5 ms max.

OFF delay time

1.5 ms max.

Number of points per common

16 points per common

Summary of Contents for DeviceNet DRT2-ID16

Page 1: ...ounting keeps track of the ON OFF operations and total operating time so preventive maintenance can be scheduled based on service life estimates The operation counter and operating time monitor functi...

Page 2: ...independently of control systems PLC Configurator Control I O DRT2 series Smart Slave Pneumatic valve Maintenance information Easy to view Display 2 3 Sensor Cylinder Control System Maintenance System...

Page 3: ...nction provides notification of maintenance timing for input and output devices such as switches and actuators Energized Time Monitor Function Every six minutes the Slave records the total energized t...

Page 4: ...nd model number for each contact e g sensors and valves comments can be set for each of the input and output contacts in the Slaves Confirmation and preparation of replacement parts when failures occu...

Page 5: ...t Slaves that are removed from the network when correcting an error enabling more effective maintenance Improved Structural Flexibility Smallest in Its Class The width of the Basic Unit is 115 mm 77 o...

Page 6: ...ening torque M3 power supply I O terminals 0 3 to 0 5 N m Item Specification Model number DRT2 ID16 DRT2 ID16 1 Internal I O common processing NPN PNP Number of I O points 16 inputs ON voltage 15 VDC...

Page 7: ...NP Photocoupler Photocoupler Photocoupler Photocoupler 0 1 G V 24 VDC 0 1 G V 24 VDC Internal circuit Internal circuit Voltage step down Voltage step down DRT2 ID16 1 PNP DRT2 ID16 NPN V 10 1 11 3 12...

Page 8: ...pansion outputs NPN XWT 0D08 8 expansion outputs PNP XWT OD08 1 16 expansion inputs NPN XWT ID16 16 expansion inputs PNP XWT ID16 1 16 expansion outputs NPN XWT OD16 16 expanison outputs PNP XWT OD16...

Reviews: