Network Power Voltage Monitor 
Function

The network power voltage status and the I/O power status 
can be understood at a glance via the network.

The network power voltage is recorded in the Slave (network 
power voltage monitor function). It is also possible to detect 
whether the I/O power supply is turned ON, and to output a warn-
ing if it is not (I/O power status monitor function). This means that 
the status of the network power voltage and I/O power supply for 
each SmartSlave can be confirmed at a glance from the Configu-
rator, contributing to reductions in startup time.

Communication Error History Monitor 
Function

Causes for communications errors can be monitored.

 

Information (i.e., communication error code and network power 
voltage at the time) for four previous errors can be recorded in the 
Slave. This error history can be read from Smart Slaves that are 
removed from the network when correcting an error, enabling 
more effective maintenance.

Improved Structural Flexibility

Smallest in Its Class

The width of the Basic Unit is 115 mm (77% of 150-mm DRT1-
series models) and the width of the Expansion Unit is 94 mm, giv-
ing a total expanded width of 209 mm, making it the smallest 
device of its class in the industry.

Easy Mounting and Dismounting of Terminal Blocks

Terminal blocks can be mounted and dismounted with ease.

Easy Expansion with Expansion Units

The Smart Slaves can be expanded easily by freely combining 
Expansion Units with Basic Units using snap-on mounting. This 
means less wiring work is required.

Clamp-type Communications Connectors

Input Filter Function

The influence of noise can be removed using the ON response 
time. Also, very small pulses that are shorter than the communica-
tions time can be handled using the OFF response time.

Function for Handling Sensor Inrush Current

In order to prevent incorrect input due to inrush current when, for 
example, power to a sensor is turned ON, the Slave can be set not 
to accept input for 100 ms after input supply is turned ON.

Summary of Contents for DeviceNet DRT2-ID16

Page 1: ...ounting keeps track of the ON OFF operations and total operating time so preventive maintenance can be scheduled based on service life estimates The operation counter and operating time monitor functi...

Page 2: ...independently of control systems PLC Configurator Control I O DRT2 series Smart Slave Pneumatic valve Maintenance information Easy to view Display 2 3 Sensor Cylinder Control System Maintenance System...

Page 3: ...nction provides notification of maintenance timing for input and output devices such as switches and actuators Energized Time Monitor Function Every six minutes the Slave records the total energized t...

Page 4: ...nd model number for each contact e g sensors and valves comments can be set for each of the input and output contacts in the Slaves Confirmation and preparation of replacement parts when failures occu...

Page 5: ...t Slaves that are removed from the network when correcting an error enabling more effective maintenance Improved Structural Flexibility Smallest in Its Class The width of the Basic Unit is 115 mm 77 o...

Page 6: ...ening torque M3 power supply I O terminals 0 3 to 0 5 N m Item Specification Model number DRT2 ID16 DRT2 ID16 1 Internal I O common processing NPN PNP Number of I O points 16 inputs ON voltage 15 VDC...

Page 7: ...NP Photocoupler Photocoupler Photocoupler Photocoupler 0 1 G V 24 VDC 0 1 G V 24 VDC Internal circuit Internal circuit Voltage step down Voltage step down DRT2 ID16 1 PNP DRT2 ID16 NPN V 10 1 11 3 12...

Page 8: ...pansion outputs NPN XWT 0D08 8 expansion outputs PNP XWT OD08 1 16 expansion inputs NPN XWT ID16 16 expansion inputs PNP XWT ID16 1 16 expansion outputs NPN XWT OD16 16 expanison outputs PNP XWT OD16...

Reviews: