background image

DRT2-ID16/OD16

DRT2-ID16/OD16

A threshold value can be set in the Slave so that a flag turns ON 
when this value is exceeded. (This is possible with both the con-
tact operation counter function and the energized time monitor 
function.) This makes it possible to identify when parts approach 
the end of their service life, and provides useful data for preventive 
maintenance.

Unit Comment/Connected Slaves 
Function

Identification of fault locations and confirmation of replace-
ment parts can be performed quickly.

Unit Command Function

Setting the location in the Slave’s internal comments means that 
the Slave can be detected from the Configurator.

Connected Devices Comment Function

By setting the maker name and model number for each contact 
(e.g., sensors and valves), comments can be set for each of the 
input and output contacts in the Slaves.

Confirmation and preparation of replacement parts when failures 
occur can be performed quickly.

All of this data can be handled as electronic data and can therefore 
be used, for example, to create electronic manuals or databases of 
maintenance parts.

Network Startup

Networks can be started up simply by making rotary switch 
settings and connecting network cables.

Easy Node Address Setting

Node addresses are set with easy-to-use rotary switches.

Automatic Baud Rate Recognition Function

The automatic baud rate recognition function eliminates the need 
for DIP switches.

No Wiring Required for Unit’s Internal Circuit Power 
Supply

Power for the Unit’s internal circuits is obtained from the network 
power and so no wiring is required for the Unit’s internal circuit 
power supply.

Summary of Contents for DeviceNet DRT2-ID16

Page 1: ...ounting keeps track of the ON OFF operations and total operating time so preventive maintenance can be scheduled based on service life estimates The operation counter and operating time monitor functi...

Page 2: ...independently of control systems PLC Configurator Control I O DRT2 series Smart Slave Pneumatic valve Maintenance information Easy to view Display 2 3 Sensor Cylinder Control System Maintenance System...

Page 3: ...nction provides notification of maintenance timing for input and output devices such as switches and actuators Energized Time Monitor Function Every six minutes the Slave records the total energized t...

Page 4: ...nd model number for each contact e g sensors and valves comments can be set for each of the input and output contacts in the Slaves Confirmation and preparation of replacement parts when failures occu...

Page 5: ...t Slaves that are removed from the network when correcting an error enabling more effective maintenance Improved Structural Flexibility Smallest in Its Class The width of the Basic Unit is 115 mm 77 o...

Page 6: ...ening torque M3 power supply I O terminals 0 3 to 0 5 N m Item Specification Model number DRT2 ID16 DRT2 ID16 1 Internal I O common processing NPN PNP Number of I O points 16 inputs ON voltage 15 VDC...

Page 7: ...NP Photocoupler Photocoupler Photocoupler Photocoupler 0 1 G V 24 VDC 0 1 G V 24 VDC Internal circuit Internal circuit Voltage step down Voltage step down DRT2 ID16 1 PNP DRT2 ID16 NPN V 10 1 11 3 12...

Page 8: ...pansion outputs NPN XWT 0D08 8 expansion outputs PNP XWT OD08 1 16 expansion inputs NPN XWT ID16 16 expansion inputs PNP XWT ID16 1 16 expansion outputs NPN XWT OD16 16 expanison outputs PNP XWT OD16...