D6FZ

8

Air Flow Station

*1.

Up to 8 Sensors can be connected when the recording cycle is 2 seconds or longer; up to 4 Sensors can be connected when the recording 

cycle is 1 second.

*2.

Data is automatically written to the SD memory card when the internal memory reaches its capacity and recording continues until the SD 

memory card capacity is reached. Recording stops if there is no SD memory card inserted, when the internal memory capacity is reached, or 

when the SD memory card is write protected. (Recording can be resumed after inserting an SD memory card and outputting the data to it by 

pressing a button.) The default is Continue Mode. Use the PC Software to change the recording mode.

*3.

Recording of the latest measured values continues until the internal memory reaches its capacity. (If the internal memory capacity is exceeded, 

data is overwritten from the oldest data in the memory.)

*4.

An alarm is output when the upper or lower limit of the air flow that was set in threshold setting mode is exceeded.

*5.

You can temporarily read and write data with an SD card that complies with SD/SDHC card standards and was made by another company, 

but the SD card may suddenly not be recognized, preventing you from accessing the data.

*6.

When mounting the Sensor with magnets, be sure to install it in a location where it will not be subjected to shock.

*7.

A T-branch connector to connect to D6FZ-FC02.

*8.

OMRON's XW4B-02B1-H1 Connector.

ItemModel

D6FZ-FGX21

Connectable Sensors

D6FZ-FGT200, D6FZ-FGT500, and D6FZ-FGS1000

Maximum number of connected Sensors

8

*

1

Indications

7-segment 5-digit 2-row LCD, auxiliary information indicators

Recording interval

1 s, 2 s, 5 s, 10 s, 20 s, 30 s, or 1 min

Displayed data

Momentary flow rate, total flow rate, pressure, temperature, and billing amount/CO

2

 conversion

Recorded data

Momentary flow rate, total flow rate, volume flow rate, pressure, and temperature

Calculation functions

Conversion of total flow rate to billing amount/CO

2

Recording modes

Continue Mode

*

2

 and Ring Mode

*

3

External output

Alarm output (photocoupler output)

*

4

Communications interface

Ethernet (10Base-T or 100Base-TX)

Internal storage device

Internal memory: Approx. 4,200 data items when 1 Sensor is connected, Approx. 650 data items 

when 8 Sensors are connected.

External storage device

SD card (to save measured values and to save/read set values), Recommended SD card: HMC-

SD291 (manufactured by OMRON)

*

5

Power supply voltage

DC input: 24 VDC ±10%, ripple (p-p): 10% max.

Current consumption

80 mA max.

Operating temperature

Without Ethernet: 

10 to 40°C (with no condensation or icing), with Ethernet: 0 to 40°C (with no 

condensation or icing)

Operating humidity

35% to 85% RH (with no condensation or icing)

Storage humidity/temperature

15 to 60°C, 20% to 85% RH (with no condensation or icing)

Insulation resistance

20 M

Ω

 (at 500 VDC)

Withstand voltage

1,000 VAC, 50/60 Hz for 1 min

Vibration resistance (destruction)

10 to 150 Hz with a 0.7-mm double amplitude or acceleration of 50 m/s

2

 for 80 min each in X, Y, 

and Z directions

Shock resistance (destruction)

150 m/s

2

 3 times each in six directions (up/down, left/right, forward/backward)

*

6

Material

ABS

Degree of protection

IP30

Mounting method

Magnet mounting, screw mounting, or hooks

Dimensions

117.2 × 24.6 × 56.8  mm (W×D×H) (excluding protruding parts)

Weight (in package)

Approx. 150 g (Approx. 500 g)

Accessories

Instruction Sheet, Startup Guide, Connection Cable,

*

7

 Alarm Output Connector

*

8

Summary of Contents for D6FZ Series

Page 1: ...s Features For the most recent information on models that have been certified for safety standards refer to your OMRON website Consequently Identify the waste that had previously been invisible to red...

Page 2: ...e and Temperature The Sensor provides multiple sensing functions You can identify compressed air conditions with just one Sensor Multi sensing Mountable to Curved Pipes or Couplers The built in silenc...

Page 3: ...n the flow rates Display Reversal You can reverse the display direction to match the installation direction Always use one of the specified installation directions 500L type Pipe size 15A Rc1 2 200L t...

Page 4: ...example side by side comparison of flow rates by the day for different months is possible e e n In the Office Data storing and analyzing on a computer By stopping the supply of compressed air with a s...

Page 5: ...ion T branch Connector Cable with Connector on One End 3 m D6FZ FGS1000 S Appearance Product name Model T branch Connector D6FZ FC02 D6FZ FGT Air Flow Sensor only Mounting Bracket Mounting Bracket 1 P...

Page 6: ...Pressure loss 2 kPa max 4 kPa max Power supply voltage 12 to 24 VDC 10 ripple p p 10 max Current consumption 120 mA max Functions Momentary flow total flow display reversal zero point adjustment peak...

Page 7: ...ections up down left right forward backward Pressure loss Direct piping 10 kPa max 0 5 MPa at maximum flow Using Coupler TL model from Nagahori Industry Co Ltd 10 kPa max 0 5 MPa at maximum flow Power...

Page 8: ...ry information indicators Recording interval 1 s 2 s 5 s 10 s 20 s 30 s or 1 min Displayed data Momentary flow rate total flow rate pressure temperature and billing amount CO2 conversion Recorded data...

Page 9: ...B B B B B B B Terminal block RS 485 RS 485 PLC 24 V power supply RS 485 Connections to Air Flow Station RS 485 Connections to PLC Refer to the user s manuals for the Wireless Unit and Air Flow Sensor...

Page 10: ...ic pressure 0 5MPa 0 75MPa 0 1 2 0 500 100 200 300 400 Pressure loss kPa Flow rate L min std atmospheric pressure 0 5MPa 0 75MPa 0 2 4 1 3 Temperature C Pressure MPa Minimum flow rate L min std Maximu...

Page 11: ...of straight pipe with the same opening diameter just before and after the Sensor Refer to Flow rate accuracy characteristics for a length of straight pipe on page 10 for the required straight pipe len...

Page 12: ...mm 15 47 15 Four 3 2 dia 0 1 holes 16 0 1 49 5 0 1 D6FZ FGT200 Mounting Hole Dimensions 63 7 30 33 7 77 12 65 70 60 89 65 Rc1 2 Effective depth 10 mm 49 5 0 1 16 0 1 7 Four M3 Effective depth 5 mm 30...

Page 13: ...7 10 12 4 5 dia through hole 8 dia countersinking depth 2 M12 plug CN0 CN1 CN2 14 9 dia 18 14 9 dia 14 9 dia 4 5 d i a t h r o u g h h o l e 8 d ia C o u n te rs u n k h o le d e p th 2 Back 56 M12 so...

Page 14: ...her in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted Suitability of Use Omron Companies shall not be responsible for conformity...

Reviews: