D6FZ
8
Air Flow Station
*1.
Up to 8 Sensors can be connected when the recording cycle is 2 seconds or longer; up to 4 Sensors can be connected when the recording
cycle is 1 second.
*2.
Data is automatically written to the SD memory card when the internal memory reaches its capacity and recording continues until the SD
memory card capacity is reached. Recording stops if there is no SD memory card inserted, when the internal memory capacity is reached, or
when the SD memory card is write protected. (Recording can be resumed after inserting an SD memory card and outputting the data to it by
pressing a button.) The default is Continue Mode. Use the PC Software to change the recording mode.
*3.
Recording of the latest measured values continues until the internal memory reaches its capacity. (If the internal memory capacity is exceeded,
data is overwritten from the oldest data in the memory.)
*4.
An alarm is output when the upper or lower limit of the air flow that was set in threshold setting mode is exceeded.
*5.
You can temporarily read and write data with an SD card that complies with SD/SDHC card standards and was made by another company,
but the SD card may suddenly not be recognized, preventing you from accessing the data.
*6.
When mounting the Sensor with magnets, be sure to install it in a location where it will not be subjected to shock.
*7.
A T-branch connector to connect to D6FZ-FC02.
*8.
OMRON's XW4B-02B1-H1 Connector.
ItemModel
D6FZ-FGX21
Connectable Sensors
D6FZ-FGT200, D6FZ-FGT500, and D6FZ-FGS1000
Maximum number of connected Sensors
8
*
1
Indications
7-segment 5-digit 2-row LCD, auxiliary information indicators
Recording interval
1 s, 2 s, 5 s, 10 s, 20 s, 30 s, or 1 min
Displayed data
Momentary flow rate, total flow rate, pressure, temperature, and billing amount/CO
2
conversion
Recorded data
Momentary flow rate, total flow rate, volume flow rate, pressure, and temperature
Calculation functions
Conversion of total flow rate to billing amount/CO
2
Recording modes
Continue Mode
*
2
and Ring Mode
*
3
External output
Alarm output (photocoupler output)
*
4
Communications interface
Ethernet (10Base-T or 100Base-TX)
Internal storage device
Internal memory: Approx. 4,200 data items when 1 Sensor is connected, Approx. 650 data items
when 8 Sensors are connected.
External storage device
SD card (to save measured values and to save/read set values), Recommended SD card: HMC-
SD291 (manufactured by OMRON)
*
5
Power supply voltage
DC input: 24 VDC ±10%, ripple (p-p): 10% max.
Current consumption
80 mA max.
Operating temperature
Without Ethernet:
−
10 to 40°C (with no condensation or icing), with Ethernet: 0 to 40°C (with no
condensation or icing)
Operating humidity
35% to 85% RH (with no condensation or icing)
Storage humidity/temperature
−
15 to 60°C, 20% to 85% RH (with no condensation or icing)
Insulation resistance
20 M
Ω
(at 500 VDC)
Withstand voltage
1,000 VAC, 50/60 Hz for 1 min
Vibration resistance (destruction)
10 to 150 Hz with a 0.7-mm double amplitude or acceleration of 50 m/s
2
for 80 min each in X, Y,
and Z directions
Shock resistance (destruction)
150 m/s
2
3 times each in six directions (up/down, left/right, forward/backward)
*
6
Material
ABS
Degree of protection
IP30
Mounting method
Magnet mounting, screw mounting, or hooks
Dimensions
117.2 × 24.6 × 56.8 mm (W×D×H) (excluding protruding parts)
Weight (in package)
Approx. 150 g (Approx. 500 g)
Accessories
Instruction Sheet, Startup Guide, Connection Cable,
*
7
Alarm Output Connector
*
8