3
D6FZ
One analog output
Two pulse outputs
RS-485 communications
IP65
Display
Threshold values (peak, bottom, and leak)
Peak/Bottom hold
Auto-tuning
Key lock
Main
Features
Feature
Comparison
Flow
measurement
Leakage
measurement
Pressure
measurement
Temperature
measurement
Curved pipe
g
mounti
ng
Resistant to oils
and
mi
st
Station
connection
Multi-sensor
connection
Note: Omron survey (as of June 2013)
Specifications are the same as the 1000L type.
Ideal for Compressed Air Measurements
at
Machines
Leakage Measurement
A high measurement accuracy of ±0.5% F.S. is achieved
at a low flow rate of less than 50 L/min.
This allows you to identify the air flow that is discarded
as leakage when machines are not operating to save money.
Zero Reset
You can use the zero reset to identify seasonal
or day /night variations in the flow rates.
Display Reversal
You can reverse the display direction to
match the installation direction.
Always use one of the specified installation
directions.
500L type
Pipe size: 15A (Rc1/2)
200L type
Pipe size: 8A (Rc1/4)
Note: According to OMRON investigation in June 2013.
Averaging count setting
ave
Clear total flow rate
clr
11-segment 8-digit
LCD
The characters are easy to read, and the total flow rate
can be checked in a glance.
Easy to Read
Flow Straightener with Honeycomb Structure
A honeycomb structure effectively straightens
the flow to keep pressure loss low.
Other Features
Highly Accurate Flow Measurements
An OMRON MEMS chip is used to achieve the highest
accuracy in the industry* of ±2% F.S. (at 50 L/min or less).
High Accuracy
First in the industry!
*
Honeycomb structure
Press and hold.
Leakage on non-working days
(Saturday and Sunday) was 36 m
3
!
Press and hold to reverse.
Temperature
sensor
Heater
element
Temperature
sensor
Flow
With Flow
Without Flow
Leakage
1
Pressure
3
Usage
2
D6FZ-FGT200/500