D4DS

D4DS

9

Precautions

CAUTION

Do not dismount the operation key from the door intentionally
and insert it to the switch with the door open. Machine may
start operating and injury or death may be caused.

Do not use metal connectors or conduits with this switch. Rigid
connectors and conduits may damage the switch. The broken
conduit hole may cause an electrical shock hazard.

Install the operation key so that it will not hit the operator when the
door is open.

If the D4DS is to be used as a switch in an emergency stop circuit or
in a safety circuit for preventing accidents resulting in injuries or
deaths, use NC contacts with a forced release mechanism and set
the D4DS so that it will operate in positive opening mode. For safety,
install the Switch and the Operation Key using one-way rotational
screws or other similar means to prevent them from easily coming
off. Protect the D4DS with an appropriate cover and post a warning
sign near the D4DS in order to ensure the safety of the door.

To prevent the D4DS from damage due to circuit short-circuiting,
connect a fuse with a breaking current 1.5 to 2 times larger than the
rated current of the D4DS in series to the D4DS.

If the D4DS is used under EN-approved conditions, use a gI or gG
10-A fuse approved by IEC269.

Mounting

Be sure to mount the D4DS with a stopper as shown in the following
illustration. Do not use the casing of the D4DS as a stopper. Be sure
to install the stopper so that the space “a” will be a maximum of
3 mm.

Stopper

Switch

 Correct Use

Operating Environment

Do not use the D4DS in the following environments, otherwise the
D4DS may malfunction.

Locations subject to significant temperature fluctuations

Humid locations where there is a risk of condensation

Locations subject to significant vibrations

Locations subject to metal chips, oils, and chemicals inside a
protective door

Operation Key

Be sure to use a special Operation Key only. Do not operate the
D4DS with anything other than the special Operation Key, otherwise
the D4DS may break or the safety of the system may not be main-
tained.

Do not impose excessive force on the Operation Key inserted into
the D4DS or drop the D4DS with the Operation Key inserted, other-
wise the Operation Key may deform or break.

Excessive force

Drop

Secure the Operation Key with screws so that the Operation Key
cannot be removed with ease.

Refer to 

Dimensions for the mounting dimensions of the Operation

Key and properly mount and the Operation Key correctly so that the
position and angle will be correct.

Make sure that the Operation Key can be inserted properly with a
tolerance of 

±

0.5 mm in the upward, downward, left, or right direc-

tion, otherwise the D4DS may soon become damaged.

±

1 min.

±

1 min.

Summary of Contents for D4DS

Page 1: ...915 2 conduit 9509913 SUVA SUVA 1 conduit 6010Z 2 conduit 6011Z Note CSA C22 2 No 14 compliance was verified and approved by UL Marked with E u Ordering Information Model Number Legend Limit Switch 1 Conduit 1 Pg13 5 1 conduit 2 G1 2 1 conduit 3 1 2 14NPT 1 conduit 5 Pg13 5 2 conduit 6 G1 2 2 conduit 2 Built in Switch 5 1NC 1NO Slow action A 2NC Slow action 3 Head Mounting Direction F Four mountin...

Page 2: ... G1 2 D4DS 25FS D4DS 2AFS 1 2 14NPT D4DS 35FS D4DS 3AFS 2 conduit Pg13 5 D4DS 55FS D4DS 5AFS G1 2 D4DS 65FS D4DS 6AFS Accessories Order Separately Operation Keys Type Model Horizontal mounting D4DS K1 Vertical mounting D4DS K2 Horizontal adjustable vertical mounting D4DS K3 Vertical Horizontal adjustable vertical mounting D4DS K5 ...

Page 3: ...tween terminals of same polarity between terminals of different polarity and between each terminal and non current carrying metal part EN60947 5 1 Rated insulation voltage Ui 400 V EN60947 5 1 Conditional short circuit current 100 A EN60947 5 1 Short circuit protective device SCPD 10 A fuse type gI or gG IEC269 Switching overvoltage 1 500 V max EN60947 5 1 Pollution degree operating environment 3 ...

Page 4: ...rections including the downward direction Cover The cover with a hinge on its lower part can be opened by removing the screw of the cover which ensures ease of maintenance and wiring Built in Switch Has a positive opening mechanism which forcibly separates the NC contacts even if they are welded The built in switch incorporates a pair each of NC contacts and NO contacts or two pairs of NC contacts...

Page 5: ...d contacts are marked according to EN60947 5 1 Positive Opening Mechanism 1NC 1NO Contact Slow action 2NC Contact Slow action Contact spring Return spring Fixed contact NC Movable contact Plunger Fixed contact NO Contact spring Return spring Fixed contact NC Movable contact Plunger Only the NC contacts have a positive open ing function When metal deposition occurs the contacts are separated from e...

Page 6: ...varies with the model as follows Conduit thread Model Pg13 5 D4DS 1jjS 5jjS G1 2 D4DS 2jjS 6jjS 1 2 14NPT D4DS 3jjS See note 3 on page 107 1 conduit Models D4DS 1jjS D4DS 2jjS D4DS 3jjS 2 conduit Models D4DS 5jjS D4DS 6jjS R2 15 0 05 mounting holes depth 5 Two 4 0 15 0 dia holes 30 x 30 30 x 30 Cap depth 5 Two 4 0 15 0 dia holes 56 max R2 15 0 05 mounting holes See note 3 on page 107 ...

Page 7: ...Mounting D4DS K3 Horizontal adjustable Vertical Mounting Four R2 15 Four R2 15 9 dia 8 dia 4 5 dia Note Each dimension has a tolerance of 0 4 mm unless otherwise specified D4DS K5 Horizontal Vertical adjustable Vertical Mounting 18 Two M4 9 0 1 41 0 1 43 0 1 Mounting Holes ...

Page 8: ...rmissible difference in center lines between the Operation Key and key hole 44 to 46 5 Key insertion face Permissible difference in center lines be tween the Operation Key and key hole Horizontal key insertion radius R y 200 44 to 46 5 Key insertion face Horizontal key insertion radius R y 200 Permissible difference in center lines between the Operation Key and key hole 44 to 46 5 Key insertion fa...

Page 9: ...proved by IEC269 Mounting Be sure to mount the D4DS with a stopper as shown in the following illustration Do not use the casing of the D4DS as a stopper Be sure to install the stopper so that the space a will be a maximum of 3 mm Stopper Switch Correct Use Operating Environment Do not use the D4DS in the following environments otherwise the D4DS may malfunction Locations subject to significant tem...

Page 10: ...ate tightening torque 2 This force range applies to 1 2 14NPT Mounting Switch Two M4 Allen head bolts with washers must be used in order to mount the D4DS securely To mount the D4DS more securely pre pare two 4 0 05 0 15 dia protruding portions with 4 8 mm maxi mum in height each as shown below and support the D4DS at a total of four points Mounting Dimensions with Protruding Portions Standard Mod...

Page 11: ...me in contact with the case or cover Terminal screw Crimp terminal Correct Incorrect Crimp style terminal Crimp style terminal Conduit Opening Tighten the connector to a torque of 1 8 to 2 2 N S m 1 37 to 1 77 N S m if it is a 1 2 14NPT Excessive tightening torque may damage the casing In order to continue satisfying IP65 apply seal ing tape to the connector conduit The diameter of the cable must ...

Reviews: