background image

D4DS

D4DS

3

Specifications

 Approved Standard Ratings

TÜV and BIA (EN60947-5-1)

Utilization category

AC-15

Rated operating current (I

e

)

2 A

Rated operating voltage (U

e

)

400 V

Note:

Use a 10-A fuse type gl or gG as a short-circuit protection device that conforms to IEC269.

UL (UL508/CSA C22.2 No.14)

A600

Rated voltage

Carry current

Current

Volt-amperes

Ca y cu e

Make

Break

Make

Break

120 VAC

10 A

60 A

6 A

7,200 VA

720 VA

240 VAC

30 A

3 A

480 VAC

15 A

1.5 A

600 VAC

12 A

1.2 A

 Characteristics

Degree of protection (see note 1)

IP65 (EN60947-5-1)

Life expectancy (see note 2)

Mechanical: 1,000,000 operations min.
Electrical:

150,000 operations min.

Operating speed

0.1 m/s to 0.5 m/s

Contact gap

2 x 2.0 mm min.

Operating frequency

30 operations/minute min.

Positive opening force (see note 3)

58.84 N min.

Positive opening travel (see note 3)

10 mm min.

Insulation resistance

100 M

 min. (at 500 VDC) between terminals of same polarity, between terminals of

different polarity, between each terminal and ground, and between each terminal and
non-current-carrying metal part

Contact resistance

25 m

 max. (initial value)

Dielectric strength

U

imp

 4 kV between terminals of same polarity, between terminals of different polarity, and

between each terminal and non-current-carrying metal part (EN60947-5-1)

Rated insulation voltage (U

i

)

400 V (EN60947-5-1)

Conditional short-circuit current

100 A (EN60947-5-1)

Short-circuit protective device (SCPD)

10 A, fuse type gI or gG (IEC269)

Switching overvoltage

1,500 V max. (EN60947-5-1)

Pollution degree
(operating environment)

3 (EN60947-5-1)

Conventional enclosed thermal current
(I

the

)

10 A (EN60947-5-1)

Protection against electric shock

Class II (double insulation)

Vibration resistance

Malfunction: 10 to 500 Hz, 0.65-mm single amplitude with an imposed acceleration of
100 m/s

2

 max.

Shock resistance

Destruction: 1,000 m/s

2

 min.

Malfunction: 300 m/s

2

 min.

Ambient temperature

Operating:

–30

°

C to 70

°

C (with no icing)

Ambient humidity

Operating:

95% max.

Weight

Approx. 76 g (for D4DS-15FS)

Note:

1. Although the Switch casing resists dust, oil, and water, make sure that the keyhole on the head is free from dust, oil, water, and

chemical, otherwise the D4DS may wear out, break, or malfunction.

2. Life expectancy values are calculated at an operating temperature of 5

°

C to 35

°

C, and an operating humidity of 40% to 70%. Con-

tact your OMRON sales representative for more detailed information on other operating environments.

3. These figures are minimum requirements for safe operation.

Summary of Contents for D4DS

Page 1: ...915 2 conduit 9509913 SUVA SUVA 1 conduit 6010Z 2 conduit 6011Z Note CSA C22 2 No 14 compliance was verified and approved by UL Marked with E u Ordering Information Model Number Legend Limit Switch 1 Conduit 1 Pg13 5 1 conduit 2 G1 2 1 conduit 3 1 2 14NPT 1 conduit 5 Pg13 5 2 conduit 6 G1 2 2 conduit 2 Built in Switch 5 1NC 1NO Slow action A 2NC Slow action 3 Head Mounting Direction F Four mountin...

Page 2: ... G1 2 D4DS 25FS D4DS 2AFS 1 2 14NPT D4DS 35FS D4DS 3AFS 2 conduit Pg13 5 D4DS 55FS D4DS 5AFS G1 2 D4DS 65FS D4DS 6AFS Accessories Order Separately Operation Keys Type Model Horizontal mounting D4DS K1 Vertical mounting D4DS K2 Horizontal adjustable vertical mounting D4DS K3 Vertical Horizontal adjustable vertical mounting D4DS K5 ...

Page 3: ...tween terminals of same polarity between terminals of different polarity and between each terminal and non current carrying metal part EN60947 5 1 Rated insulation voltage Ui 400 V EN60947 5 1 Conditional short circuit current 100 A EN60947 5 1 Short circuit protective device SCPD 10 A fuse type gI or gG IEC269 Switching overvoltage 1 500 V max EN60947 5 1 Pollution degree operating environment 3 ...

Page 4: ...rections including the downward direction Cover The cover with a hinge on its lower part can be opened by removing the screw of the cover which ensures ease of maintenance and wiring Built in Switch Has a positive opening mechanism which forcibly separates the NC contacts even if they are welded The built in switch incorporates a pair each of NC contacts and NO contacts or two pairs of NC contacts...

Page 5: ...d contacts are marked according to EN60947 5 1 Positive Opening Mechanism 1NC 1NO Contact Slow action 2NC Contact Slow action Contact spring Return spring Fixed contact NC Movable contact Plunger Fixed contact NO Contact spring Return spring Fixed contact NC Movable contact Plunger Only the NC contacts have a positive open ing function When metal deposition occurs the contacts are separated from e...

Page 6: ...varies with the model as follows Conduit thread Model Pg13 5 D4DS 1jjS 5jjS G1 2 D4DS 2jjS 6jjS 1 2 14NPT D4DS 3jjS See note 3 on page 107 1 conduit Models D4DS 1jjS D4DS 2jjS D4DS 3jjS 2 conduit Models D4DS 5jjS D4DS 6jjS R2 15 0 05 mounting holes depth 5 Two 4 0 15 0 dia holes 30 x 30 30 x 30 Cap depth 5 Two 4 0 15 0 dia holes 56 max R2 15 0 05 mounting holes See note 3 on page 107 ...

Page 7: ...Mounting D4DS K3 Horizontal adjustable Vertical Mounting Four R2 15 Four R2 15 9 dia 8 dia 4 5 dia Note Each dimension has a tolerance of 0 4 mm unless otherwise specified D4DS K5 Horizontal Vertical adjustable Vertical Mounting 18 Two M4 9 0 1 41 0 1 43 0 1 Mounting Holes ...

Page 8: ...rmissible difference in center lines between the Operation Key and key hole 44 to 46 5 Key insertion face Permissible difference in center lines be tween the Operation Key and key hole Horizontal key insertion radius R y 200 44 to 46 5 Key insertion face Horizontal key insertion radius R y 200 Permissible difference in center lines between the Operation Key and key hole 44 to 46 5 Key insertion fa...

Page 9: ...proved by IEC269 Mounting Be sure to mount the D4DS with a stopper as shown in the following illustration Do not use the casing of the D4DS as a stopper Be sure to install the stopper so that the space a will be a maximum of 3 mm Stopper Switch Correct Use Operating Environment Do not use the D4DS in the following environments otherwise the D4DS may malfunction Locations subject to significant tem...

Page 10: ...ate tightening torque 2 This force range applies to 1 2 14NPT Mounting Switch Two M4 Allen head bolts with washers must be used in order to mount the D4DS securely To mount the D4DS more securely pre pare two 4 0 05 0 15 dia protruding portions with 4 8 mm maxi mum in height each as shown below and support the D4DS at a total of four points Mounting Dimensions with Protruding Portions Standard Mod...

Page 11: ...me in contact with the case or cover Terminal screw Crimp terminal Correct Incorrect Crimp style terminal Crimp style terminal Conduit Opening Tighten the connector to a torque of 1 8 to 2 2 N S m 1 37 to 1 77 N S m if it is a 1 2 14NPT Excessive tightening torque may damage the casing In order to continue satisfying IP65 apply seal ing tape to the connector conduit The diameter of the cable must ...

Reviews: