D4DS
D4DS
11
•
Horizontal/Vertical-adjustable Vertical Mounting
D4DS-K5
Two, M4
9
±
0.1
41
±
0.1
43
±
0.1
Securing the Door
When the door is closed (with the Operation Key inserted), the door
(or the Operation Key) may be pushed back across the set zone due
to the door’s weight, the door cushion rubber, etc. If load is applied to
the Operation Key, the door may fail to unlock. Secure the door with
hooks so that it will remain within in the set zone.
Set zone
(0.5 to 3 mm)
Operation Key
Changes in Head Mounting Direction
By removing the screws on the four corners of the head, the head
can be reset in any of four directions.
When changing the head mounting direction, make sure that the
Operation Key is in the head.
Make sure that no foreign materials penetrate through the mounting
holes of the head. Internal screws of the head must not be removed,
otherwise the internal parts of the head may be lost or deformed.
Wiring
Do not connect lead wires directly to the terminals. Be sure to con-
nect the lead wires through insulation tubes and crimp terminals.,
and tighten each terminal screw within an optimum torque range.
The lead wires must be an AWG20 to AWG14 type (i.e., 0.5 to
25 mm
2
thick).
D dia.
dz dia.
dz dia.:
3.7
D dia.:
4.5
B:
7.0
L:
20.2
F:
7.7
I:
9.0 (mm)
Wire the crimp terminal as shown in the following diagram so that it
will not come in contact with the case or cover.
Terminal screw
Crimp terminal
Correct
Incorrect
Crimp-style terminal
Crimp-style terminal
Conduit Opening
Tighten the connector to a torque of 1.8 to 2.2 N
S
m (1.37 to
1.77 N
S
m if it is a 1/2-14NPT). Excessive tightening torque may
damage the casing. In order to continue satisfying IP65, apply seal-
ing tape to the connector conduit.
The diameter of the cable must be suited to the corresponding con-
nector.
Properly attach the provided conduit cap to the unused conduit
opening and securely tighten the cap screw within a torque range
between 1.27 and 1.67 N
S
m when wiring the D4DS two-conduit
model.
Recommended Connector
Size
Manufacturer
Model
Suitable cable
dia.
G1/2
OMRON
SC-6
7.5 to 9.0 mm
LAPP
(see note 1)
ST-PF1/2
5360-1002
6.0 to 12.0 mm
Ohm Electric
OA-W1609
7.0 to 9.0 mm
Pg13.5
LAPP
(see note 1)
ST13.5
5301-5030
5.0 to 12.0 mm
1/2-14NPT
LAPP
(see note 1)
ST-NPT1/2
5301-6030
6.0 to 12.0 mm
Note:
1. LAPP is a German manufacturer.
2. Ohm Denki is a Japanese manufacturer.
Maintenance and Repairs
The user must not maintain or repair equipment incorporating any
D4DS model. Contact the manufacturer of the equipment for any
maintenance or repairs required.
The user must not maintain or repair equipment incorporating any
D4DS model. Contact the manufacturer of the equipment for any
maintenance or repairs required.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. C104-E1-2A