background image

Enclosed Switch

 

D4C

F-11

Lim

it 

Switch

es

Ordering Information

List of Models

Standard Models

Note 1.

Cold-resistant models are also available. Order these models with reference to the following example.
D4C-1201 

 D4C-1201-C

2.

Models with viscosity-resistant oil specification (with an oil drain hole) are also available. Order these models with reference to the following
example. Applicable only to the plunger models.
D4C-1202 

 D4C-1202-M

3.

Variable roller lever models are also available.
*

Oil-resistant vinyl cabtire cables.

** Ordinary vinyl cabtire cables.

*** Models with SJT(O) Cables (approved by UL and CSA standards) conform to UL and CSA standards.

Actuator

Standard cable models

UL/CSA-approved cable models

S-FLEX VCTF Cable*

VCTF Cable**

5 A at 250 VAC without 

LED indicator

5 A at 125 VAC with LED 

indicator (100 VAC)

SJT(O) Cable***

EN60947-5-1 approved

UL/CSA approved

2  m

3  m

5  m

2  m

3  m

5  m

3  m

5  m

3  m

5  m

D4C-

@

801

D4C-

@

201

D4C-

@

301

D4C-

@

901

D4C-

@

401

D4C-

@

501

D4C-1601

D4C-1701

D4C-2601

D4C-2701

D4C-

@

831

D4C-

@

231

D4C-

@

331

D4C-

@

931

D4C-

@

431

D4C-

@

531

D4C-1631

D4C-1731

D4C-2631

D4C-2731

D4C-

@

802

D4C-

@

202

D4C-

@

302

D4C-

@

902

D4C-

@

402

D4C-

@

502

D4C-1602

D4C-1702

D4C-2602

D4C-2702

D4C-

@

832

D4C-

@

232

D4C-

@

332

D4C-

@

932

D4C-

@

432

D4C-

@

532

D4C-1632

D4C-1732

D4C-2632

D4C-2732

D4C-

@

803

D4C-

@

203

D4C-

@

303

D4C-

@

903

D4C-

@

403

D4C-

@

503

D4C-1603

D4C-1703

D4C-2603

D4C-2703

D4C-

@

833

D4C-

@

233

D4C-

@

333

D4C-

@

933

D4C-

@

433

D4C-

@

533

D4C-1633

D4C-1733

D4C-2633

D4C-2733

D4C-

@

810

D4C-

@

210

D4C-

@

310

D4C-

@

910

D4C-

@

410

D4C-

@

510

D4C-1610

D4C-1710

D4C-2610

D4C-2710

D4C-

@

850

D4C-

@

250

D4C-

@

350

D4C-

@

950

D4C-

@

450

D4C-

@

550

D4C-1650

D4C-1750

D4C-2650

D4C-2750

D4C-

@

820

D4C-

@

220

D4C-

@

320

D4C-

@

920

D4C-

@

420

D4C-

@

520

D4C-1620

D4C-1720

D4C-2620

D4C-2720

D4C-

@

824

D4C-

@

224

D4C-

@

324

D4C-

@

924

D4C-

@

424

D4C-

@

524

D4C-1624

D4C-1724

D4C-2624

D4C-2724

D4C-

@

841

D4C-

@

241

D4C-

@

341

D4C-

@

941

D4C-

@

441

D4C-

@

541

D4C-1641

D4C-1741

D4C-2641

D4C-2741

D4C-

@

842

D4C-

@

242

D4C-

@

342

D4C-

@

942

D4C-

@

442

D4C-

@

542

D4C-1642

D4C-1742

D4C-2642

D4C-2742

D4C-

@

843

D4C-

@

243

D4C-

@

343

D4C-

@

943

D4C-

@

443

D4C-

@

543

D4C-1643

D4C-1743

D4C-2643

D4C-2743

D4C-

@

860

D4C-

@

260

D4C-

@

360

D4C-

@

960

D4C-

@

460

D4C-

@

560

D4C-1660

D4C-1760

D4C-2660

D4C-2760

Pin 
plunger

Sealed 
plunger

Roller 
plunger

Sealed roller 
plunger

Crossroller 
plunger

Sealed 
crossroller 
plunger

Bevel 
plunger

Coil 
spring

Roller 
lever

Roller lever 
(high-sensitivity 
model)

Panel mount 
pin plunger

Panel mount 
roller plunger

Panel mount 
crossroller 
plunger

Center roller 
lever plunger

Summary of Contents for D4C -

Page 1: ...indicator 4 0 1 A at 125 VAC 0 1 A at 30 VDC 5 0 1 A at 125 VAC with LED indicator 6 0 1 A at 30 VDC with LED indicator 2 Cable Specifications 2 VCTF oil resistant cable 3 m 3 VCTF oil resistant cable...

Page 2: ...ces 2 conductors NO wiring 4 Cable length 03 0 3 m 05 0 5 m 10 1 m Wiring Specifications Note Since the above wiring specifications are different from those for the D4CC be careful not to mistake them...

Page 3: ...2 D4C 902 D4C 402 D4C 502 D4C 1602 D4C 1702 D4C 2602 D4C 2702 D4C 832 D4C 232 D4C 332 D4C 932 D4C 432 D4C 532 D4C 1632 D4C 1732 D4C 2632 D4C 2732 D4C 803 D4C 203 D4C 303 D4C 903 D4C 403 D4C 503 D4C 16...

Page 4: ...2 M D4C 1G24 3 M D4C 1G24 5 M D4C 1G41 1 M D4C 1G41 2 M D4C 1G41 3 M D4C 1G41 5 M D4C 1G42 1 M D4C 1G42 2 M D4C 1G42 3 M D4C 1G42 5 M D4C 1G43 1 M D4C 1G43 2 M D4C 1G43 3 M D4C 1G43 5 M Actuator 1 A a...

Page 5: ...20 P D4C 6220 P 5 m D4C 1320 P D4C 4320 P D4C 2320 P D4C 3320 P D4C 5320 P D4C 6320 P 3 m D4C 1224 P D4C 4224 P D4C 2224 P D4C 3224 P D4C 5224 P D4C 6224 P 5 m D4C 1324 P D4C 4324 P D4C 2324 P D4C 332...

Page 6: ...voltage Non inductive load Inductive load Inrush current Resistive load Lamp load Inductive load Motor load NC NO NC NO NC NO NC NO NC NO D4C 1 125 VAC 5 A 5 A 1 5 A 0 7 A 3 A 3 A 2 5 A 1 3 A 20 A ma...

Page 7: ...current Resistive load Lamp load Inductive load Motor load NC NO NC NO NC NO NC NO NC NO 125 VAC 1 1 1 0 7 1 1 1 1 20 A max 10 A max 30 VDC 1 1 1 1 1 1 1 1 Rated voltage Carry current Current Volt am...

Page 8: ...47 5 1 Switching overvoltage 1 000 VAC 300 VDC max EN60947 5 1 Pollution degree operating environment 3 IEC60947 5 1 Short circuit protective device SCPD 10 A fuse type gG IEC269 Conditional short cir...

Page 9: ...x 11 77 N 11 77 N 11 77 N 6 67 N RF min 4 41 N 4 41 N 4 41 N 1 47 N PT max 1 8 mm 1 8 mm 1 8 mm 10 3 OT min 3 mm 3 mm 3 mm 50 MD max 0 2 mm 0 2 mm 0 2 mm 3 OP 31 2 1 mm 36 8 1 mm 36 8 mm TT 5 mm 5 mm...

Page 10: ...uator is in the free position the indicator is lit and when the actuator is turned or pushed and the contact comes into contact with the NO side the indicator turns OFF 3 4 2 Without LED Indicator AC...

Page 11: ...1 7 mA 15 k 0 10 50 100 300 500 1 000 3 000 5 000 30 50 100 300 500 1 000 3 000 10 000 5 000 7 000 30 0 20 40 60 80 100 120 1 2 3 4 5 6 7 Operating frequency 30 operations min cos 1 L R 0 Operating te...

Page 12: ...r Setscrew This screw is made of stainless steel and has high corrosion resistance Built in Switch Both standard load and microload models available Rotary Shaft The shaft is made of stainless steel d...

Page 13: ...teel roller Correct setting position 51 5 max 67 max 40 max Rubber cap 49 max 40 max 49 max 54 2 max 40 max Pin Plunger D4C 01 Sealed Plunger D4C 31 Roller Plunger D4C 02 10 dia stainless steel plunge...

Page 14: ...er Plunger D4C 32 Rubber cap 49 max 40 max 12 dia x 5 stainless steel roller 0 Two 5 1 0 2 dia holes Spot facing 10 2 dia Depth 6 VCTF cable 0 75 mm2 4 conductor Finishing O D 7 6 12 dia x 5 stainless...

Page 15: ...0 2 dia holes Spot facing 10 2 dia Depth 6 Correct setting position VCTF cable 0 75 mm2 4 conductor Finishing O D 7 6 Note 1 Operation is possible in any direction except in par allel to the axis 2 Th...

Page 16: ...ess sintered roller M5 length 12 Allen head bolt 0 Two 5 1 0 2 dia holes Spot facing 10 2 dia Depth 6 VCTF cable 0 75 mm2 4 conductor Finishing O D 7 6 see note Note S FLEX VCTF Cables are used for we...

Page 17: ...t Pin Plunger D4C 41 Panel Mount Roller Plunger D4C 42 Panel Mount Crossroller Plunger D4C 43 49 max 40 max 10 dia stainless steel plunger 0 Two 5 1 0 2 dia holes Spot facing 10 2 dia Depth 6 Correct...

Page 18: ...Sealed Roller Plunger Sealed Pin Plunger D4C 001 K1EJ D4C 001 M1J D4C 002 K1EJ D4C 002 M1J D4C 031 K1EJ D4C 031 M1J D4C 032 K1EJ D4C 032 M1J 0 Two 5 1 0 2 dia holes Spot facing 10 2 dia Depth 6 Corre...

Page 19: ...ng 10 2 dia Depth 6 Adjustable Roller Lever D4C 27 P Adjustable Rod Lever D4C 29 P 40 max 30R to 75R variable 40 max 65 max 65 max 57 7 max 55 max 17 5 dia x 7 stainless steel roller M5 length 16 Alle...

Page 20: ...lts and two M5 x 0 8 Allen head bolts are provided 0 Note 1 Tighten the 5 2 0 2 dia holes with the M5 x 10 hexagon pan head screws 2 Insert the M5 Allen head bolts into the M5 tapping holes to tighten...

Page 21: ...imit Switch for the EN ratings use the gI or gG 10 A fuse Operation Operation method shapes of cam and dog operating frequency and overtravel have a significant effect on the service life and precisio...

Page 22: ...Tighten each screw to a torque according to the following table Note By removing the two screws from the head the head direction can be rotated 180 After changing the head direction re tight en to th...

Reviews: