![background image](http://html1.mh-extra.com/html/omron/d4c/d4c_datasheet_744317011.webp)
Enclosed Switch
D4C
F-19
Lim
it
Switch
es
Engineering Data
■
Electrical Durability
■
Leakage Current for LED-indicator Models
Model
Voltage
Leakage current
Resistance
D4C-2
@@@
125 VAC
1.7 mA
68 k
Ω
D4C-3
@@@
30 VDC
1.7 mA
15 k
Ω
D4C-5
@@@
125 VAC
1.7 mA
68 k
Ω
D4C-6
@@@
30 VDC
1.7 mA
15 k
Ω
0
10
50
100
300
500
1,000
3,000
5,000
30
50
100
300
500
1,000
3,000
10,000
5,000
7,000
30
0
20
40
60
80
100
120
1
2
3
4
5
6
7
Operating frequency: 30 operations/min
(cos
φ
= 1, L/R = 0)
Operating temperature: 5
°
C to 35
°
C
Operating humidity: 40% to 70%
Operating frequency: 30 operations/min
(cos
φ
=1, L/R = 0)
Switching current (mA)
Switching current (mA)
Dur
ability (x 10
3
oper
ations)
Dur
ability (x 10
3
oper
ations)
D4C-4
@@@
, -5
@@@
, -6
@@@
30 VDC
125 VAC
125 VAC
250 VAC
D4C-1
@@@
, -2
@@@
, -3
@@@