F-14
Enclosed Switch
D4C
Remarks
There is no difference in mounting pitch between the Mounting Plate
and the WL. The mounting depth of the D4C with the Mounting Plate
attached is, however, shorter than that of the panel-mounted WL.
Specifications
■
Approved Standards
Note 1:
Models with VCTF oil-resistant cables only.
2:
Pre-wired models only.
3:
SJT(0)-cable models only.
■
Approved Standard Ratings
General Ratings
Plate
WL
D4C
Agency
Standard
File No.
TÜV Rheinland
EN60947-5-1
R9451333 (see note 1)
J9950970 (see note 2)
UL
UL508
E76675 (see note 3)
CSA
CSA C22.2 No. 14
LR45746 (see note 3)
Model
Rated voltage
Non-inductive load
Inductive load
Inrush current
Resistive load
Lamp load
Inductive load
Motor load
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
D4C-1
@@@
125 VAC
5 A
5 A
1.5 A
0.7 A
3 A
3 A
2.5 A
1.3 A
20 A
max.
10 A
max.
250 VAC
5 A
5 A
1 A
0.5 A
2 A
2 A
1.5 A
0.8 A
8 VDC
5 A
5 A
2 A
2 A
5 A
4 A
3 A
3 A
14 VDC
5 A
5 A
2 A
2 A
4 A
4 A
3 A
3 A
30 VDC
4 A
4 A
2 A
2 A
3 A
3 A
3 A
3 A
125 VDC
0.4 A
0.4 A
0.05 A
0.05 A
0.4 A
0.4 A
0.05 A
0.05 A
250 VDC
0.2 A
0.2 A
0.03 A
0.03 A
0.2 A
0.2 A
0.03 A
0.03 A
D4C-2
@@@
125 VAC
5 A
5 A
1.5 A
0.7 A
3 A
3 A
2.5 A
1.3 A
125 VDC
0.4 A
0.4 A
0.05 A
0.05 A
0.4 A
0.4 A
0.05 A
0.05 A
D4C-3
@@@
30 VDC
4 A
4 A
2 A
2 A
3 A
3 A
3 A
3 A
D4C-4
@@@
125 VAC
0.1 A
0.1 A
---
---
8 VDC
0.1 A
0.1 A
14 VDC
0.1 A
0.1 A
30 VDC
0.1 A
0.1 A
D4C-5
@@@
125 VAC
0.1 A
0.1 A
---
---
D4C-6
@@@
30 VDC
0.1 A
0.1 A
---
---