CV/CVM1 instruction
CS-series Instruction
Operand
Number of Operands
LINE(115)
LINE(63)
The data type of the 2nd operand is changed from BCD to BIN. For a constant, the # mark is
converted to & mark. To use word data, change the data type of word from BCD to BIN.
Same as CV/CVM1
COLM(116)
COLM(64)
The data type of the 3rd operand is changed from BCD to BIN. For a constant, the # mark is
converted to & mark. To use word data, change the data type of word from BCD to BIN.
Same as CV/CVM1
TCNT(123)
None
This instruction is not supported. Consider programming with the CNT instruction.
TSR(124)
TSR(780)
The data specification of the operand is different. Refer to the
SYSMAC CS/CS/NSJ Series
INSTRUCTIONS REFERENCE MANUAL (Cat No. W474
), and correct the data.
Same as CV/CVM1
TSW(125)
TSW(781)
The data specification of the operand is different. Refer to the
SYSMAC CS/CS/NSJ Series
INSTRUCTIONS REFERENCE MANUAL (Cat No. W474
), and correct the data.
Same as CV/CVM1
SSET(160)
SSET(630)
The data specification of the operand is different. Refer to the
SYSMAC CS/CS/NSJ Series
INSTRUCTIONS REFERENCE MANUAL (Cat No. W474
), and correct the data.
Same as CV/CVM1
SRCH(164)
SRCH(181)
The data specification of the operand is different. Refer to the
SYSMAC CS/CS/NSJ Series
INSTRUCTIONS REFERENCE MANUAL (Cat No. W474
), and correct the data.
Same as CV/CVM1
MAX(165)
MAX(182)
The data specification of the operand is different. Refer to the
SYSMAC CS/CS/NSJ Series
INSTRUCTIONS REFERENCE MANUAL (Cat No. W474
), and correct the data.
Same as CV/CVM1
MIN(166)
MIN(183)
The data specification of the operand is different. Refer to the
SYSMAC CS/CS/NSJ Series
INSTRUCTIONS REFERENCE MANUAL (Cat No. W474
), and correct the data.
Same as CV/CVM1
SUM(167)
SUM(184)
The data specification of the operand is different. Refer to the
SYSMAC CS/CS/NSJ Series
INSTRUCTIONS REFERENCE MANUAL (Cat No. W474
), and correct the data.
Same as CV/CVM1
EMBC(171)
EMBC(281)
The data type of operand is changed from BIN data to BCD. For a constant, the # mark is converted
to & mark. To use word data, change the data type of word from BCD to BIN.
Same as CV/CVM1
REGL(175)
None
This instruction is not supported. Consider programming with other data transfer instruction.
REGS(176)
None
This instruction is not supported. Consider programming with other data transfer instruction.
FPD(177)
FPD(269)
The data specification of the operand is different. Refer to the
SYSMAC CS/CS/NSJ Series
INSTRUCTIONS REFERENCE MANUAL (Cat No. W474
), and correct the data.
Same as CV/CVM1
FILR(180)
None
This instruction is not supported. Consider programming with the FREAD instruction.
FILW(181)
None
This instruction is not supported. Consider programming with the FWRIT instruction.
FILP(182)
None
This instruction is not supported. Consider the online editing or so.
FLSP(183)
None
This instruction is not supported. Consider the online editing or so.
IOSP(187)
None
This instruction is not supported. Consider selecting “Normal” for the Execution Mode of CS/CJ.
(Select “Normal”.for the Execution mode on Peripheral Service tab on the PLC Settings window.).
IORS(188)
None
This instruction is not supported. Consider selecting “Normal” for the Execution Mode of CS/CJ.
(Select “Normal”.for the Execution mode on Peripheral Service tab on the PLC Settings window.).
IODP(189)
None
This instruction is not supported. Consider displaying data by using a touch panel or other device.
READ(190)
None
This instruction is not supported. Consider programming with the IORD instruction.
The data of the Special I/O Unit is reflected directly in the I/O memory of PLC. Please refer to the
operation manual of the Special I/O Unit that you use.
WRIT(191)
None
This instruction is not supported. Consider programming with the IOWR instruction.
The data that is written to the I/O memory of PLC is directly reflected to the Special I/O Unit. Please
refer to the operation manual of the Special I/O Unit that you use.
MSG(195)
MSG(46)
The data type of the 1st operand is changed from BCD to BIN. For a constant, the # mark is
converted to & mark. To use word data, change the data type of word from BCD to BIN.
Same as CV/CVM1
TOUT
None
This instruction is not supported. Consider programming with the OUT instruction.
SA(210)
SA(784)
The data specification of operand is different. Refer to the SYSMAC CS/CJ/NSJ Series
INSTRUCTIONS REFERENCE MANUAL (Cat. No. W474) and CX-Programmer Ver.9.[]
OPERATION MANUAL SFC Programming (Cat. No. W469), and correct the data.
Same as CV/CVM1
SP(211)
None
This instruction is not supported. Consider programming with another SFC related instruction.
SR(212)
None
This instruction is not supported. Consider programming with another SFC related instruction.
SF(213)
None
This instruction is not supported. Consider programming with another SFC related instruction.
SE(214)
SE(785)
The data specification of operand is different. Refer to the SYSMAC CS/CJ/NSJ Series
INSTRUCTIONS REFERENCE MANUAL (Cat. No. W474) and CX-Programmer Ver.9.[]
OPERATION MANUAL SFC Programming (Cat. No. W469), and correct the data.
Same as CV/CVM1
SOFF(215)
None
This instruction is not supported. Consider programming with other SFC related instructions.
CSP(221)
CSP(510)
The data type of operand is changed from BCD to BIN. For a constant, the # mark is converted to &
mark. To use word data, change the data type of word from BCD to BIN.
Same as CV/CVM1
CSPN(222)
CSPN(511)
The data type of operand is changed from BCD to BIN. For a constant, the # mark is converted to
& mark. To use word data, change the data type of word from BCD to BIN.
Same as CV/CVM1
CNR(236)
CNR(545)
The data specification of the operand is different. Refer to the
SYSMAC CS/CS/NSJ Series
INSTRUCTIONS REFERENCE MANUAL (Cat No. W474
), and correct the data.
It might be different.
PID(270)
PID(190)
The data specification of the operand is different. Refer to the
SYSMAC CS/CS/NSJ Series
INSTRUCTIONS REFERENCE MANUAL (Cat No. W474
), and correct the data.
Same as CV/CVM1
RD2(280)
None
This instruction is not supported. Consider programming with the IORD instruction.
The data of the Special I/O Unit is reflected directly in the I/O memory of PLC. Please refer to the
operation manual of the Special I/O Unit that you use.
WR2(281)
None
This instruction is not supported. Consider programming with the IOWR instruction.
The data that is written to the I/O memory of PLC is directly reflected to the Special I/O Unit.
Please refer to the operation manual of the Special I/O Unit that you use.
TST(350)
TST(350)
The data type of the 2nd operand is changed from BCD to BIN. For a constant, the # mark is
converted to & mark. To use word data, change the data type of word from BCD to BIN.
Same as CV/CVM1
TSTN(351)
TSTN(351)
The data type of the 2nd operand is changed from BCD to BIN. For a constant, the # mark is
converted to & mark. To use word data, change the data type of word from BCD to BIN.
Same as CV/CVM1
13