The table below lists the models of CV/CVM1 series Units and corresponding models of CS-series Units. Select a
CS series model which is compatible with or one with similar specification to the CV/CVM1 series model you use.
Refer to the following manual for details of each model.
CS Series CPU Unit OPERATION MANUAL (Cat. No. W339)
CPU Rack
Unit name
CV/CVM1 series
CS-series
Description
CPU Units
CV500-CPU01(-V1)
CVM1-CPU01(-V1/V2)
CVM1-CPU11(-V1/V2)
CS1G-CPU44H to 45H
CS1H-CPU64H to 65H
UM: 30K to 60K steps,
DM+EM: 64K to 128K words
Number of expansions:
CPU44H: 3 max., CPU45H/64H/65H: 7 max.
CV1000-CPU01(-V1)
CV2000-CPU01(-V1)
CVM1-CPU21(-V1/V2)
CS1G-CPU45H
CS1G-CPU65H to 67H
UM: 60K to 250K steps
DM+EM: 64K to 448K words
Number of expansions: 7 max.
Memory card
HMC-ES[][][] (SRAM)
HMC-EE[][][] (EEP-ROM)
HMC-EP[][][] (EP-ROM)
HMC-EF[][][]
Flash memory type only for CS
Expansion Data Memory CV1000-DM641 (64 KW)
CV1000-DM151 (128 KW)
CV1000-DM251 (256 KW)
Unnecessary
CS-series CPU Units have built-in EM Area.
The memory capacity is different by models.
Select CPU Units with enough memory capacity.
Power Supply Units
CV500-PS221
CVM1-PA208
C200HW-PA209R
C200HW-PA204R
C200HW-PA204
C200HW-PA204C
AC type
Note: The Power Supply Units with a RUN Output have “-R” at the end of their model No.
CV500-PS211
C200HW-PD025
C200HW-PD024
DC type
Note: No RUN Output type provided.
CPU Backplanes
CV500-BC031 (3 slots)
CV500-BC053 (5 slots)
CV500-BC101 (10 slots)
CVM1-BC053( 5 slots)
CVM1-BC103 (10 slots)
CS1W-BC033/032 (3 slots)*
CS1W-BC053/052 (5 slots)*
CS1W-BC083/082 (8 slots)*
CS1W-BC103/102 (10 slots)*
Both CS1 Units and C200H Units can be used for CS1W-BC[][]3.
Only CS1 Units can be used for CS1W-BC[][]2. C200H Units cannot be used.
*When an I/O Control Unit for long distance expansion is mounted, the number of Units that can be
mounted on the backplane will decrease by one.
Expansion Units
(I/O Control Units)
CV500-IC101
CV500-IC201
CV500-IC301
CS1W-IC101
(I/O Control Unit for long
distance expansion)
or
Unnecessary (when total
expansion length is 12 m or
less.)
The I/O Control Unit is necessary when the total expansion cable length exceeds 12 m.
(The Unit can be used even if the total expansion legth is 12 m or less. You can also directly connect
the Expansion cable to the Backplane without using an I/O Control Unit.)
Note: When an I/O Control Unit for long distance expansion is mounted, the number of available slots
decreases by one.
Electrical Isolation
Sleeve
(CV500-ATT04/ATT05)
CV500-ATT04
CV500-ATT05
Unnecessary
The noise-preventing spacer is unnecessary for CS, because CS Units are installed by isolating from