Chapter 5: System Cable Installation
Installing a SmartController EX Motion Controller
Refer to the
SmartController EX User’s Guide
for complete information on installing the optional
SmartController EX. This list summarizes the main steps.
1. Mount the SmartController EX and Front Panel.
2. Connect the Front Panel to the SmartController EX.
3. Connect the pendant (if purchased) to the SmartController EX.
Connect a jumper plug, if no pendant is being used.
4. Connect user-supplied 24 VDC power to the controller.
Instructions for creating the 24 VDC cable, and power specification, are covered in the
SmartController EX User’s Guide
.
5. Install a user-supplied ground wire between the SmartController EX and ground.
List of Cables and Parts
Table 5-3. Cables and Parts Description (with SmartController EX)
Part
Cable and Parts
List
Part #
Standard Option
User-
supplied
Notes
A
eAIB XSYS Cable
13323-
000
X
B
User E-Stop, Safety
Gate
n/a
X
C
XUSR Jumper Plug
04736-
000
X
Required if no E-
stop, safety gate or
muted safety gate
used.
D
Front Panel
90356-
10358
X
X
Front Panel (D) or
Front Panel Jumper
Plug (F) must be
used.
E
Front Panel Cable
10356-
10500
X
X
F
Front Panel Jumper
Plug
10053-
000
X
Front Panel (D) or
Front Panel Jumper
Plug (F) must be
used.
G
XMCP Jumper Plug
10052-
000
X
XMCP Jumper Plug
(G), T20 Bypass
Plug (H), or T20
Pendant must be
used.
05624-000 Rev. K
Cobra 350 User's Guide
57