3-6
Setup of the Galvo Scanner
3-6-1
Wiring of Devices
The figures below show how to wire the CK3M to the Galvo Scanner.
varioSCAN
DSCB
DSIB-SL
IntelliSCAN
CK3W-AX2323
£
CK3W-GC2200
a
b
Connect the sections a and b in the above figures as follows.
a. Connection between the Controller and the Galvo Scanner
Connect the XY connector of the CK3W-GC2200 to the SL2-100 connector of the intelliSCAN with
the dedicated cable CK3W-CAG03A.
CK3W-GC2200
XY-IN+
Signal
IntelliSCAN
Signal
Pin
1
XY-IN-
6
XY-OUT+
2
XY-OUT-
7
Pin
5
9
1
6
DATA OUT+
DATA-OUT-
DATA-IN+
DATA-IN-
b. Connection between the Controller and the dynamic focusing unit
Connect the Z connector of the CK3W-GC2200 to the DIGITAL IN connector of the DSIB-SL with
the dedicated cable CK3W-CAG03A.
3 Connection Procedures
3-44
Application Guide Laser Application (O052)
Summary of Contents for CK3M-CPU 1 Series