background image

REFERENCE

NOTE

NOTE

NOTE

- 7 -

- 8 -

- 9 -

- 10 -

Please check whether the date, date of 

birth, gender and height settings are wrong.

Refer to CHANGE/DELETE PERSONAL 

DATA (        Page 8).

Even if the date, date of birth, gender and 

height are correctly set, you may not take a 

measurement in case that they exceed the 

measurement range available or the user is 

under a suitable age.

Refer to SPECIFICATIONS display 

(        Page 10).

The registered value or the body 

composition value exceeds the 

measurement range available.

Some result is displayed as 

“              ”

2

“CHANGE” and “DEL” blink on the display.

Touch the        (SET) button to cancel the operation.

Touch the      (SET) button again.

disappear.

3
4

Stand still in the correct posture to take a 

measurement.

Refer to CORRECT MEASUREMENT 

METHOD (

        

Page 5).

Wipe the water or dirt off the buttons and 

try again.

Product Name

Body Composition Monitor

Model

HBF-224 (HBF-224-APDB)

Display*

Body Weight:

Weight Gap:

BMI:
Body Fat percentage:

Body fat percentage classification:

Resting Metabolism:

Skeletal Muscle percentage:

Skeletal muscle percentage classification:

Visceral Fat Level:

Visceral fat level classification:

Body Age:

1 to 30 level with an increment of 1 level

0 (Normal) / + (High) / ++ (Very High) 3 levels

18 to 80 years old with an increment of 1 year

Memory:

Last measurement results

Set Items

Weight Accuracy

Above 2.0 kg to 40.0 kg: ±400 g

Above 40.1 kg to 135.0 kg: ±1%

Power Supply

4 AAA manganese batteries (R03)

[You may also use 4 AAA alkaline batteries (LR03).]

Battery Life

Approximately 1 year (When AAA manganese batteries are used in accordance with the test condition)

+5°C to +35°C, 30 % to 85 % RH

-20°C to +60°C, 10 % to 95 % RH, 700 hPa - 1060 hPa

Weight

Approximately 1.6 kg (including batteries)

External Dimensions Approximately 285 (W) × 28 (H) × 280 (D) mm

Package Contents

Body Composition Monitor, trial battery (4 AAA manganese batteries) and instruction manual

Error Display

Cause

Correction

Cause

Correction

Problem

TROUBLESHOOTING TIPS

Feet are too dry.

The batteries are worn out.

Batteries are not inserted.

The buttons are wet or dirty.

12. SPECIFICATIONS

13. TECHNICAL DATA

11. TROUBLESHOOTING

Wait until “0.0 kg” is displayed before 

stepping onto the unit.

Place the unit on a hard and level floor.

Warm yourself up, and then take a 

measurement once you feel your circulation 

is back to normal.

Slightly moisten the soles of your feet 

with a damp towel and try again.
Select your personal profile number before 

measurement.

Refer to Select Personal Profile Number 

and Take a Measurement on HOW TO 

TAKE A MEASUREMENT (

        

Page 7).

Replace the batteries with new ones. Refer to 

BATTERY INSTALLATION (        Page 3).

Insert the batteries.

Refer to BATTERY INSTALLATION 

(        Page 3).

Insert the batteries in correct alignment. 

Refer to BATTERY INSTALLATION 

(

        

Page 3).

Place the unit in a warm room for a few 

minutes, and then take a measurement 

when you feel cold no longer by touching 

the electrodes.

1

All symbols appear on the display briefly, then the display changes to “0.0kg”.

2

Select your Personal Profile Number.

Select your Personal Profile Number or GUEST 

correctly before making a measurement.

Refer to Select Personal Profile Number and 

Take a Measurement on HOW TO TAKE A 

MEASUREMENT (        Page 7).

If your Personal Profile Number is incorrect…

If you select an incorrect Personal Profile Number…

Select your correct Personal Profile Number with the        or        button and touch the        

(SET) 

button.

Then, your Personal Profile Number is confirmed and

          disappears.

Once you touch the        

(SET) button, you have to select your Personal Profile Number again.

Therefore, select a correct Personal Profile Number with the

        or        button and touch the

(SET) button to make a confirmation.

7-2. Select Personal Profile Number and Take a

Measurement

When “            ” to “            ” blink,

Touch the buttons one by one.

You step off the unit during the 
measurement.

Do not step off the unit till the measurement is completed.  

(Refer to CORRECT MEASUREMENT METHOD.

)       

Page 5

Make sure that you are standing on the unit correctly and try again.

(Refer to CORRECT MEASUREMENT METHOD.

)       

Page 5

Remain still and do not move during measurement.

Slightly moisten the soles of your feet with a damp towel and try 
again.

(Refer to CORRECT MEASUREMENT METHOD.

)       

Page 5

Wait until 0.0 kg is displayed before stepping onto the unit.

Do not move the unit until 0.0 kg is displayed.

Do not move till measurement is completed.

Your feet are not correctly positioned 
on the electrodes.
The measurement position is not 
stable or your feet are not placed 
correctly.
Feet are too dry.

The unit is not set up correctly.

You step onto the unit before 0.0 kg 

is displayed.

Movement during measurement.
When measuring, body weight range is exceeded.

The unit moved before 0.0 kg is 

displayed.

Select your Personal Profile Number or “GUEST” with 
the      or      button and touch the      (SET) button.

Nothing is displayed when the 

power is turned on.

The polarities of batteries are not 

aligned correctly.

“0.0 kg” is displayed or the weight 

value barely increases even when 

you step onto the unit.

The value of body weight is 

displayed abnormally high or low.

You stepped onto the unit before 

“0.0 kg” was displayed.

The measured value is 

displayed abnormally high or 

low.

The measured values vary 

widely for each measurement.

Your posture is not correct and 

measurement cannot be taken.

The measurement is taken on soft floor 

surface such as carpet or uneven floor 

surface.

The soles of your feet, or whole 

body are cold, causing poor blood 

circulation

The electrodes are extremely cold.

You are not correctly recognized 

by the automatic recognition 

function.

Your body weight has changed a lot 

since last measurement.
Your body type and weight are 

similar to another user who has been 

registered.

You want to measure your body 

composition, but body composition 

measurement does not start after 

the weight measurement has been 

displayed.

You select “No.0” for your body 

weight only. (A Personal Profile 

Number or GUEST is not displayed)

Nothing happened when you 

touch the buttons.

You touch the buttons while standing 

on the main unit.

Step off the main unit before touching 

them.

You touch two or more buttons at the 

same time.

The power is automatically 

turned off.

2 to 100 kg with an increment of 0.1 kg

100 to 135 kg with an increment of 0.2 kg

-99.9 to 99.9kg

2.5 to 90.0 with an increment of 0.1
5.0 to 50.0% with an increment of 0.1%

- (Low) / 0 (Normal) / + (High) / ++ (Very High) 4 levels

385 to 3999 kcal with an increment of 1 kcal

5.0 to 60.0% with an increment of 0.1%

- (Low) / 0 (Normal) / + (High) / ++ (Very High) 4 levels

Operating 

Temperature/Humidity
Storage Temperature/

Humidity/Air Pressure

NOTE: Subject to technical modification without prior notice.

*Below 5 years old: Body weight, Weight Gap and BMI can be measured.

 

Below 17 years old: Visceral fat level and body age cannot be measured.

Above 81 years old: Body composition is for reference.

Gravity correction: 

Select “

2”

 as the area code

Date: 

January 1, 2016 to December 31, 2040

Time: 

0.00 to 23:59 24-hour notation

Personal data information:    The following information can be stored for up to 4 people.

Date of birth: 

January 1, 1900 to December 31, 2040

Gender: 

Male/female

Height: 

100.0 to 199.5 cm with an increment of 0.5 cm

Remark: You will need to set up these information each time you take a measurement as "GUEST".

Select the Personal Profile Number to be 

changed/deleted with the      or      button.

NOTE

Select the Personal Profile Number you want to register with the        or   

button and touch the        (SET) button to make a confirmation to register the 

personal data.

Refer to REGISTERING PERSONAL DATA (        Page 4).

Wrong Personal Profile Number may be displayed in the following cases.

You have a body type or body weight similar to another user.

 ・

Your body weight changes significantly.

If inaccurate recognition continues, select your Personal Profile Number before making a measurement.

Refer to Select Personal Profile Number and Take a Measurement on HOW TO TAKE A

MEASUREMENT (         Page 7).

When “No.1” to “No.4” blink or when “GUEST” is
displayed, your Personal Profile Number cannot be
registered.

Touch the      button and turn on the 

power.

Your personal data are not registered in your 
selected Personal Profile Number.
Register your personal data.

Refer to REGISTERING PERSONAL DATA 

(         Page 4).

When “            ” to “            ” blink…

Your personal data are not registered in your 
selected Personal Profile Number.
Register your personal data.

Refer to REGISTERING PERSONAL DATA 

(         Page 4).

Touch the      (SET) button to make a 

confirmation.

Refer to About the Power Off Function on BATTERY INSTALLATION 

(        Page 3).

Above 6 

years old

Above 18 

years old

- 6 -

When Error Messages Display

Remove the batteries. Wait 1 minute. Reinstall the batteries.

Touch         the button and turn on the power. Retake the 
measurement.

WEIGHT

3

Check the Measurement Results.

BODY AGE

BMI

The results display rotates automatically.
Once you confirm your Personal Profile Number, you can switch it to a measured value you 
want to view with the        or        button.

*

1

If there are no results for the last measurement or the Weight Gap exceeds the display range,

the “           ” symbol is displayed.

*

2

Use the                as a guide to measurement. In the example shown in the screen, the body 

fat percentage is determined as 0 (Normal), the visceral fat level is determined as 0 (Normal)

and the skeletal muscle percentage is determined as ++ (Very High).

Refer to UNDERSTANDING YOUR MEASUREMENT RESULTS (         Page 8) for

details of index.

RESTING 

METABOLISM

Weight Gap*

1

(

Difference From 

Last Measurement

)

BODY FAT 

PERCENTAGE

Body Fat Percentage 

Classification *

2

VISCERAL 

FAT LEVEL

Visceral Fat Level 

Classification *

2

SKELETAL 

MUSCLE 

PERCENTAGE

Skeletal Muscle 

Percentage 

Classification*

2

Hold the        button for 3 seconds or longer to turn off the power.

Turn off the power

 after you check the measurement results.

4

If there are no results for the last measurement, the “           ” symbol is displayed.

VIEWING THE LAST MEASUREMENT RESULTS

If you want to display the last measurement result, touch the        button after confirming your 
Personal Profile Number (When          is not displayed).
Touch the        button again to return to the current measurement result.
If you touch the        or        button while the last result is displayed, the result will be switched to 
another index.

You can also view the last measurement result without measuring your body composition.
Select your Personal Profile Number and touch the        button after you turn on the power and 
“0.0kg” is displayed. 

Touch the       (SET) button.

Touch the        button for 3 seconds or longer to turn off the power.

Touch the        button for 3 seconds or longer to turn off the power.

Step on the main unit.

Check the body weight result.

The body weight result blinks to inform confirmation.

Step off the main unit and turn off the power.

3

4

5

Turn off the power

after you check the measurement results.

4

2

Step off the main unit.

Refer to CORRECT MEASUREMENT METHOD (         Page 5).

3

Take a measurement.

Step on the main unit.

1

Even if you measure your weight only, it is necessary for you to register your personal data.

1

8. MEASURING WEIGHT ONLY

Touch the       button to turn on the power.

All symbols appear on the display briefly, then the display changes to “0.0kg”.

For Those Who Use the Guest Mode to Take a Measurement

2

Select weight “no 0”.

Do not touch or move the main unit or add objects on it before 

“0.0kg” is displayed. Otherwise, it might cause incorrect measurement.

What is a Guest mode?

With this mode, you can measure your body composition without registering 

your personal data in advance by entering your date of birth, gender and height 

each time. When the Guest mode is used to take a measurement, the last 

measurement result cannot be checked.

Select Guest “no-”.

2

1

Do not place this unit on cushioned floor 

surface such as on carpet or a mat to avoid incorrect 

measurement.

When the body composition is displayed, 

the measurement is finished.

Select “no 0” with the      or       button and touch the 
       (SET) button to make a confirmation.

Set the date of birth, gender and 

height.

“YEAR OF BIRTH” blinks.

Make a setting following Step 3 through Step 5 in REGISTERING 

PERSONAL DATA (         Page 4).

Measurement should be taken on level and

hard surface.

9. CHANGE/DELETE PERSONAL DATA

1

All symbols appear on the display briefly, then the display changes to “0.0kg”.

If your Personal Profile Number is used by someone else, delete it and make a registration again instead 

of changing it.

Touch the      button to turn on the 

power.

7

Touch the        or        button to cancel the 

operation.

To Change Personal Data

To Delete Personal Data

5

 Touch the      (SET) button.

The year of birth which has been registered blinks.

6

5

The “DEL” symbol blinks on the display.

Touch the       (SET) button.

6

If a wrong setting is made during change, 

confirm until the height and operate from the 

very beginning once more to make a change.

10. UNDERSTANDING YOUR MEASUREMENT RESULTS

BMI =

weight (kg)÷height (m)÷height (m)

Body Fat Percentage

Classification

- (Low)

0 (Normal)

++ (Very High)

+ (High)

<Body Age>

Visceral fat level

Level Classification

0 (Normal)

+ (High)

++ (Very High)

1 to 9

10 to 14
15 to 30

<Visceral Fat Level>

<Skeletal Muscle Percentage>

Skeletal Muscle Percentage

Classification

- (Low)

Male

Female

5.0 to 32.8%

32.9 to 35.7% 25.9 to 27.9%

28.0 to 29.0%
29.1 to 60.0%

35.8 to 37.3%
37.4 to 60.0%

0 (Normal)

+ (High)

++ (Very High)

* Based on our data

Age

(Years old)

Male

Female

6 to 7

22.0

980

22.0

920

8 to 9

27.5

1,120

27.2

1,040

10 to 11

35.5

1,330

34.5

1,200

12 to 14

48.0

1,490

46.0

1,360

15 to 17

58.4

1,580

50.6

1,280

18 to 29

63.0

1,510

50.6

1,120

30 to 49

68.5

1,530

53.0

1,150

50 to 69

65.0

1,400

53.6

1,110

70 and above

59.7

1,280

49.0

1,010

Ministry of Health, Labor and Welfare: Dietary Reference Intakes of Japanese people (2010 version)

Energy necessary for life sustaining.

<BMI>

<Resting metabolism>

<Body Fat Percentage>

5.0 to 9.9%

5.0 to 19.9%

10.0

 to 

19.9%

20.0

 to 

29.9%

20.0

 to 

24.9%

30.0

 to 

34.9%

25.0% to

35.0% to 

5.0 to 25.8%

Male

Female

Select “CHANGE” 

symbol with the      or

      button.

Follow Step 3 through Step 5 of 
REGISTERING PERSONAL DATA 
(        Page 4) to make a change.

The year of birth of the selected Personal 

Profile Number and          blink.

You can continue to measure your body composition.

If you do not take a measurement, touch the        button 

for 3 seconds or longer to turn off the power.

In accordance with the international index to judge 

obesity, an ideal body weight is at BMI “22”.

*The obesity classification standard advocated by Japan 

Society for the Study of Obesity (Year 2000).

A level to reflect the size of fat area adhered around 

viscera based on the data of our company.

*The body fat percentage is low while the visceral fat level 

is high sometimes. On the contrary, the body fat 

percentage is high while the visceral fat level is low.

*The visceral fat level is the standard to the last. Consult a 

doctor for medical diagnosis.

Standard 

Body Weight 

(kg)

Resting 

Metabolism  

(kcal/day)

Standard 

Body 

Weight (kg)

Resting 

Metabolism 

(kcal/day)

It is the proportion of the weight of skeletal muscle

to the body weight. Skeletal muscle is the muscle 

that can be trained (increased) through sports.

*The basic value is a standard. The product calculates the resting 

metabolism in accordance with the body composition result.

It is the proportion of the weight of body fat to the body

weight.

<The obesity classification value advocated by Lohman (in 1986) 

and Nagamine (in 1972) is used as a reference>

It is the age of the body calculated in accordance

with resting metabolism.

A comprehensive classification is made in 

accordance with the comparison between body age 

and actual age.

Select “DEL” symbol 

with the      or      button.

Now, you have successfully deleted 

your personal data.

Touch the        button for 3 seconds or longer to turn off 
the power.

The “CHANGE” symbol 

blinks on the display.

Now, you have successfully changed 

your personal data.

Touch the      (SET) 

button once more.

After “Clr” is displayed, the date of birth can 

be set.

Important information regarding Electro Magnetic Compatibility (EMC)

With the increased number of electronic devices such as PC’s and mobile (cellular) telephones, medical devices in 
use may be susceptible to electromagnetic interference from other devices. Electromagnetic interference may result 
in incorrect operation of the may result in incorrect operation of the medical device and create a potentially unsafe 

situation.

Medical devices should also not interfere with other devices. In order to regulate the requirements for EMC 
(Electro Magnetic Compatibility) with the aim to prevent unsafe product situations, the EN60601-1-2:2007 
standard has been implemented. This standard defines the levels of immunity to electromagnetic interferences as 
well as maximum levels of electro magnetic emissions for medical devices.
This medical device manufactured by OMRON Healthcare conforms to this EN60601-1-2:2007 standard for both 
immunity and emissions. Nevertheless, special precautions need to be observed:

Do not use mobile (cellular) telephones and other devices, which generate strong electrical or electromagnetic
fields, near the medical device. This may result in incorrect operation of the unit and create a potentially unsafe
situation. Recommendation is to keep a minimum distance of 7 m. Verify correct operation of the device in case

the distance is shorter. 

Further documentation in accordance with EN60601-1-2:2007 is available at OMRON HEALTHCARE EUROPE 

at the address mentioned in this instruction manual. 

Documentation is also available at www.omron-healthcare.com

.

OMRON HEALTHCARE Co., Ltd.

53, Kunotsubo, Terado-cho, Muko, KYOTO, 617-0002 JAPAN

Asia Pacific HQ

OMRON HEALTHCARE SINGAPORE PTE LTD.

438A Alexandra Road, #05-05/08, Alexandra Technopark, Singapore 119967

www.omronhealthcare-ap.com