B7A
B7A
114
Product List
32-point Terminals
Screw Terminal Models
Appearance
Model
I/O
classification
I/O configuration
I/O delay time
(typical)
Internal
I/O
common
Error
processing
(see note 1)
Approved
standards
B7AS-T3BS
Input
NPN compatible
Normal speed
19.2 ms
High speed
3 ms
(switch
selectable)
+/–
common
---
U, CU, CE
16-point Terminals
Screw Terminal Models
Appearance
Model
I/O
classification
I/O configuration
I/O delay
time
(typical)
Internal
I/O
common
Error
processing
(see note
1)
Approved
standards
B7A-T6A1
(see note 2)
Input
NPN compatible
Normal
speed
19 2
– common
---
U, C, CE
B7A-T6B1
(see note 2)
19.2 ms
+/–
common
---
B7A-T6C1
PNP compatible
+/–
common
---
B7A-T6A6
(see note 2)
NPN compatible
High speed
3 ms
– common
---
B7A-T6B6
(see note 2)
+/–
common
---
B7A-T6C6
PNP compatible
+/–
common
---
B7A-R6B11
Output
NPN open collector
100 mA/point
Normal
speed
+ common
HOLD
U, C, CE
B7A-R6B31
100 mA/point
speed
19.2 ms
LOAD OFF
B7A-R6C11
NPN open collector
500 mA/point (see
HOLD
CE
B7A-R6C31
500 mA/point (see
note 3)
LOAD OFF
B7A-R6F11
PNP open collector
100
A/
i t
– common
HOLD
U, C, CE
B7A-R6F31
o e co ec o
100 mA/point
LOAD OFF
U, C, C
B7A-R6G11
PNP open collector
500 mA/point (see
HOLD
CE
B7A-R6G31
500 mA/point (see
note 4)
LOAD OFF
B7A-R6B16
NPN open collector
100
A/
i t
High speed
3
+ common
HOLD
U, C, CE
B7A-R6B36
o e co ec o
100 mA/point
g s eed
3 ms
LOAD OFF
U, C, C
B7A-R6C16
NPN open collector
500 mA/point (see
HOLD
CE
B7A-R6C36
500 mA/point (see
note 3)
LOAD OFF
B7A-R6F16
PNP open collector
100
A/
i t
– common
HOLD
U, C, CE
B7A-R6F36
o e co ec o
100 mA/point
LOAD OFF
U, C, C
B7A-R6G16
PNP open collector
500 mA/point (see
HOLD
CE
B7A-R6G36
500 mA/point (see
note 4)
LOAD OFF
B7AS-T6B1
Input
NPN compatible
Normal
speed
19.2 ms
+/–
common
---
U, CU, CE
B7AS-T6B6
High speed
3 ms
---
B7AS-R6B11
Output
NPN open collector
100 mA/point
Normal
speed
HOLD
U, CU, CE
B7AS-R6B31
100 mA/point
speed
19.2 ms
LOAD OFF
B7AS-R6B16
High speed
3
HOLD
B7AS-R6B36
g s eed
3 ms
LOAD OFF
Note:
1. HOLD:
The previous output condition will be on hold when an error results.
LOAD OFF: All outputs will be OFF when an error results.