Holding Key Type (sold separately)

Use the A4EG-OP3 Holding Key when using the A4EG combining 
with the door switch. 

Use the D4NS Safety-door Switch.    

Loose screws may result in malfunction. Tighten the screws at the 
specified torques. Adhesive is recommended to prevent screws 
from being loose.
The specified torque: 0.5 to 0.7 N·m (Mounting screw, 2pcs.)

Do not impose excessive force on the tip of the Holding Key or do 
not drop the switch body when the Holding Key is mounted on the 
switch body. Otherwise the Holding Key may deform or break. Stop 
using in case that deformation or breakage of the Holding Key 
occurs. 

Use the provide Spring washers and Mounting screws when 
mounting the Holding Key. Fit a tip of a slotted-screw driver on the 
head of the Mounting screw as shown in the following figure when 
tightening Mounting screws. The Mounting screws cannot be 
released once tightened.

As shown in figure 1 in 

Precautions for Safe Use

, install the D4NS 

so that its mounting surface is above the highest part of the A4EG.

As shown in figure 1 in the 

Precautions for Safe Use

, use the 

Holding Key inserted vertically to the insert hole.

Using the A4EG-BE2R041 (Enabling Grip Switch 
Equipped with an Emergency Stop Button) 

If the A4EG is installed in a machine, do not use the A4EG alone as 
an emergency stop switch or as an emergency shutoff switch as 
specified by SEMI-S2.
SEMI-S2 specifies the installation of emergency shutoff switches at 
specified intervals on equipment. The A4EG can be removed from the 
equipment, and so may not satisfy the requirements of SEMI. Use the 
A4EG in combination with emergency stop switches or emergency 
shutoff switches that are installed at fixed positions. 

Wiring

Confirm that safety is satisfied on the operation of the equipment 
to wire.

Do not put the electric power when wiring. Otherwise electric shock 
may occur.

Use an adequate diameter of cable. The seal performance is 
reduced when the diameter is smaller than the adequate diameter. 

Use the conforming sizes of lead wires to the apply voltage and 
current. 

Conforming cable size

Recommended multi-wire cable size: A

W

G20 to 18 

(0.5 to 0.75 mm

2

Recommended cable diameter:

8.0 to 13 mm 
(used with provided Conduit 
Connector)

Do not pull the lead wires with excessive force. Doing so may 
disconnect them.

Do not pull the cable when the Enabling 
Switch Device is hung on the Bracket. 

Use crimp terminals with insulator tube for wiring.
Recommended crimp terminal (Ring tongue terminal, Nylon-

insulated): J.S.T. Mfg Co. FN1.25-3.7 (F Type)/
N1.25-3.7 (Straight Type) 

Cut and crimp the lead wires in length as shown in the following 
table.
Otherwise, excess length may cause the cover to rise and not fit 
properly.

Do not let particles such as small piece of lead wire in the switch 
body when wiring.

Terminal No. and Circuit Configuration

Assemble all of the parts without leaving any parts as shown in the 
following figure when mounting Conduit Connector. 
Mount Rubber packing, Conduit part, Cable Seal part and Spiral 
Nut part in order.

Both of the switches is ON when pushing the two push buttons 
simultaneously. Confirm that safety is satisfied on the operation of 
the equipment to wire. (A4EG-BM2B041)

Perform maintenance inspections periodically.

Holding Key 
A4EG-OP3 (sold separately)

A4EG

Mo

u

nting scre

w

, 2 pcs.

(pro

v

ided)

Spring 

w

asher, 2 pcs.

(pro

v

ided)

Length of lead wires     Terminal No.

1-4

5-8

 L1/L2
(Length to the centers of crimp terminals)

40

±

2 mm

25

±

2 mm

Model

Circuit

Terminal No.

A4EG-C000041

Enable output

1-2, 3-4

Grip output

5-6

A4EG-BE2R041

Enable output

1-2, 3-4

Emergency Stop
Pushbutton Switch output

5-6, 7-8

A4EG-BM2B041

Enable output

1-2, 3-4

Pushbutton Switch output

5-6, 7-8

Bracket
A4EG-OP2
(sold separately)

L

l

F

B

D dia.

dz dia.

t: 0.

8

 mm

dz dia.: 3.7 mm
D dia.4.0 mm
B: 5.5 mm
L: 15.7 mm
F: 4.0 mm
I: 9.0 mm

Terminal 1

Terminal 2

Terminal 3

Terminal 4

Terminal 5 Terminal 6 Terminal 7 Terminal 

8

L1

L2

Terminal Arrangement

Lead Wire Lengths

Cond

u

it part

R

ubb

er packing

Ca

b

le seal part

Spiral n

u

t part

Summary of Contents for A4EG -

Page 1: ...ld separately provides a versatile method for selecting modes Equipped with conduit connector Ordering Information Enabling Grip Switches Accessories Order Separately Be sure to read the Safety Precautions on page 12 Appearance Contact form Model Enabling switch Monitor switch Pushbutton switch Two contacts 1NC grip output None A4EG C000041 Two contacts None Emergency stop switch 2NC A4EG BE2R041 ...

Page 2: ...2 No 14 E76675 CQC CCC GB 14048 5 Pending approval Item Utilization category AC 15 DC 13 Rated operating current Ie 0 75 A 0 55 A Rated operating voltage Ue 240 V 125 V Item Section Enabling switch Emergency stop switch A4EG BE2R041 only Pushbutton A4EG BM2B041 only Rated insulation voltage 250 V Rated ON current 2 5 A 5 A 0 1 A Rated load 24 VDC 0 3 A inductive load 125 VAC 1 A resistive load EN ...

Page 3: ...ility OFF ON OFF direct opening 100 000 operations min OFF ON 1 000 000 operations min 100 000 operations min set reset for one operation 2 000 000 operations min Dielectric strength Between terminals of the same polarity 2 500 VAC 50 60 Hz 1 minute impulse voltage 1 000 VAC 50 60 Hz 1 minute 1 000 VAC 50 60 Hz 1 minute Between terminals of the different polarity 2 500 VAC 50 60 Hz 1 minute impuls...

Page 4: ...h Emergency Stop Switch Pushbutton Switch 5 7 6 8 Terminal No Terminal No Terminal No 5 7 6 8 Terminal No Terminal No 1 3 5 2 4 6 Terminal No Terminal No Terminal No 5 6 A4EG C000041 only Operation Terminal No Position 1 Position 2 Position 3 Enable output 1 to 2 3 to 4 Grip output 5 to 6 Operation Terminal No Position 1 Position 2 Position 3 Enable output 1 to 2 3 to 4 Pushbutton switch Terminal ...

Page 5: ...red by AVC Corporation of Japan included 48 34 174 60 50 262 38 44 Holding Key Mounted A4EG C000041 Enabling switch Emergency stop switch Conduit connector MG20A P 13B Flexible Super Gland Manufactured by AVC Corporation of Japan included 48 34 50 63 174 191 279 38 44 A4EG BE2R041 Holding Key Mounted Enabling switch Emergency stop switch D4NS order separately A4EG OP3 Holding Key order separately ...

Page 6: ...77 48 34 44 48 34 44 A4EG BM2B041 Holding Key Mounted Enabling switch D4NS order separately A4EG OP3 Holding Key order separately 48 34 174 189 60 292 44 47 6 102 6 76 2 54 2 50 83 2 43 3 235 9 Rubber Cover Replacement Part A4EG OP1 Mounting Bracket for Securing the A4EG A4EG OP2 Mounting surface Two 5 3 dia holes 88 50 82 t3 44 Holding Key A4EG OP3 Enabling Grip Switch Mounted Note The screws are...

Page 7: ...g Grip Switch A4EG Key type Selector Switch A22K Safety Guard Switching Unit G9SX GS Conveyor Emergency Stop Switch Normal Operation Mode Maintenance Mode Door Enabling Grip Switch When pressed processing will stop When the door is opened processing will stop Emergency Stop Switch Door Enabling Grip Switch When pressed processing will stop The Door Switch will be disabled The Enabling Grip Switch ...

Page 8: ...tc Open Open Open Open Open Feedback loop Feedback loop To PLC To PLC G9SX BC202 Control circuit S14 A2 S24 S44 S54 L1 X3 X2 X1 X4 T11 A1 T12 T21 Y1 Y3 T22 T61 T62 M1 M2 T71 Y2 Y4 T72 T31 T32 T33 T41 T42 OFF AND Auto Manual G9SX GS226 T15 Control circuit S3 S7 24 V GND GND Indicator Diagnostic check enabled Indicator Diagnostic check enabled Enabling Grip Switch S4 OPEN S5 KM3 KM4 42 41 12 11 34 3...

Page 9: ... 8 The lower unit will stop when the door is open while in operation mode 9 The door is closed and the lower unit starts again 10 The upper unit and lower unit will stop if the emergency stop is pressed G9SX BC202 Upper Unit Reset switch S2 KM1 KM2 NC contact KM1 KM2 NO contact Logical AND output L1 Logical AND input T41 Emergency stop switch S1 Guard lock safety door switch S4 Enabling grip switc...

Page 10: ...en used and contact reliability for smaller loads may be reduced Do not use the switch in the following locations Locations where the interior of the Protective Door may into direct contact with cutting chips metal filings oil chemicals Locations subject to detergents thinners or other solvents Locations subject to sudden temperature changes Locations subject to high humidity and condensation Loca...

Page 11: ...e The seal performance is reduced when the diameter is smaller than the adequate diameter Use the conforming sizes of lead wires to the apply voltage and current Conforming cable size Recommended multi wire cable size AWG20 to 18 0 5 to 0 75 mm2 Recommended cable diameter 8 0 to 13 mm used with provided Conduit Connector Do not pull the lead wires with excessive force Doing so may disconnect them ...

Page 12: ...EUROPE B V Wegalaan 67 69 NL 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 OMRON ASIA PACIFIC PTE LTD No 438A Alexandra Road 05 05 08 Lobby 2 Alexandra Technopark Singapore 119967 Tel 65 6835 3011 Fax 65 6835 2711 OMRON CHINA CO LTD Room 2211 Bank of China Tower 200 Yin Cheng Zhong Road Pu Dong New Area Shanghai 200120 China Tel 86 21 5037 2222 Fax 86 21 5037 2200 OMRON S...

Reviews: